MUR405 THRU MUR4100 Shanghai Lunsure Electronic Technology Co.,Ltd Tel:0086-21-37185008 Fax:0086-21-57152769 Features • • • • 4 Amp Super Fast Recovery Rectifier 50 to 1000 Volts High Surge Capability Low Leakage Low Forward Voltage Drop Ultra Fast Switching Speed For High Efficiency Maximum Ratings • • • DO-201AD Operating Temperature: -55°C to +150°C Storage Temperature: -55°C to +150°C o Typical Thermal Resistance 20 C/W Catalog Number MUR405 MUR410 MUR415 MUR420 MUR440 MUR460 MUR480 MUR4100 Device Marking MUR405 MUR410 MUR415 MUR420 MUR440 MUR460 MUR480 MUR4100 Maximum Recurrent Peak Reverse Voltage 50V 100V 150V 200V 400V 600V 800V 1000V Maximum RMS Voltage Maximum DC Blocking Voltage 35V 70V 105V 140V 280V 420V 550V 700V 50V 100V 150V 200V 400V 600V 800V 1000V D A Cathode Mark B D Electrical Characteristics @ 25°C Unless Otherwise Specified Average Forward Current Peak Forward Surge Current Maximum Instantaneous Forward Voltage MUR405-415 MUR420-460 MUR480-4100 Maximum DC Reverse Current At Rated DC Blocking Voltage Maximum Reverse Recovery Time MUR405-415 MUR420-460 MUR480-4100 Typical Junction Capacitance MUR405-460 MUR480-4100 IF(AV) 4.0A TA = 55°C IFSM 150A 8.3ms, half sine C DIMENSIONS VF IR 1.00V 1.35V 1.85V IFM = 4.0A; TA = 25°C* 10uA TA = 25°C 50uA TA = 100oC Trr 45ns 60ns 75ns CJ 80pF 50pF DIM A B C D INCHES MIN ----.048 1.000 IF=0.5A, IR=1.0A, Irr=0.25A Measured at 1.0MHz, VR=4.0V *Pulse test: Pulse width 300 µsec, Duty cycle 1% www.cnelectr.com MAX .370 .250 .052 --- MM MIN ----1.20 25.40 MAX 9.50 6.40 1.30 --- NOTE MUR405 thru MUR4100 Figure 1 Typical Forward Characteristics 100 60 Figure 2 Forward Derating Curve 40 6 20 5 10 6 4 4 3 2 Amps 25°C Amps 1 2 .6 1 .4 Single Phase, Half Wave 60Hz Resistive or Inductive Load .2 0 .1 0 50 75 125 150 175 °C .06 Average Forward Rectified Current - Amperesversus Ambient Temperature - °C .04 .02 .01 100 .2 .4 .6 .8 1.0 1.4 1.2 Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts Figure 3 Peak Forward Surge Current 200 150 100 75 Amps 50 25 0 1 2 4 6 8 10 20 40 60 80 100 Cycles Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles www.cnelectr.com