CIRRUS PA83M

PA83M/883
PA83M/883
P PA83M/883
r o d u c t IInnnnoovvaa t i o n FFr roomm
Table 4 Group A Inspection
SG
PARAMETER
SYMBOL
MAX
UNITS
1
1
1
1
1
1
Quiescent Current
Input Offset Voltage
Input Offset Voltage
Input Bias Current, +IN
Input Bias Current, –IN
Input Offset Current
IQ
VOS
VOS
+IB
–IB
IOS
25°C
25°C
25°C
25°C
25°C
25°C
±150V
±150V
±15V
±150V
±150V
±150V
VIN = 0, AV = 100 VIN = 0, AV = 100
VIN = 0, AV = 100
VIN = 0
VIN = 0
VIN = 0
8.5
3
5.7
50
50
50
mA
mV
mV
pA
pA
pA
3
3
3
3
3
3
Quiescent Current
Input Offset Voltage
Input Offset Voltage
Input Bias Current, +IN
Input BiasCurrent, –IN
Input Offset Current
IQ
VOS
VOS
+IB
–IB
IOS
–55°C
–55°C
–55°C
–55°C
–55°C
–55°C
±150V
±150V
±15V
±150V
±150V
±150V
VIN = 0, AV = 100
VIN = 0, AV =100
VIN = 0, AV = 100
VIN = 0
VIN = 0
VIN = 0
10
5
7.7
50
50
50
mA
mV
mV
pA
pA
pA
2
2
2
2
2
2
Quiescent Current
Input Offset Voltage
Input Offset Voltage
Input Bias Current, +IN
Input Bias Current, –IN
Input Offset Current
IQ
VOS
VOS
+IB
–IB
IOS
125°C
125°C
125°C
125°C
125°C
125°C
±150V
±150V
±15V
±150V
±150V
±150V
VIN = 0, AV = 100
VIN = 0, AV = 100
VIN = 0, AV = 100
VIN = 0
VIN = 0
VIN = 0
10
5.5
8.2
10
10
10
mA
mV
mV
nA
nA
nA
4
4
4
4
4
4
4
Output Voltage, IO = 75mA
Output Voltage, IO = 29mA
Current Limits
Stability/Noise
Slew Rate
Open Loop Gain
Common Mode Rejection
VO
VO
ICL
EN
SR
AOL
CMR
25°C
25°C
25°C
25°C
25°C
25°C
25°C
±85V
±150V
±30V
±150V
±150V
±150V
±32.5V
RL = 1K
75
RL = 5K
145
RL = 100Ω
75
125
RL = 5K, AV = 1, CL = 10nF
1
RL = 5K
20
80
RL = 5K, F = 10Hz
96
RL = 5K, F = DC, VCM = ±22.5V
90
V
V
mA
mV
V/µs
dB
dB
6
6
6
6
6
6
Output Voltage, IO = 40mA
Output Voltage, IO = 29mA
Stability/Noise
Slew Rate
Open Loop Gain
Common Mode Rejection
VO
VO
EN
SR
AOL
CMR
–55°C
–55°C
–55°C
–55°C
–55°C
–55°C
±45V
±150V
±150V
±150V
±150V
±32.5V
RL = 1K
40
RL = 5K
145
RL = 5K, AV = 1, CL = 10nF
1
RL = 5K
20
80
RL = 5K, F = 10Hz
96
RL = 5K, F = DC, VCM = ±22.5V
90
V
V
mV
V/µs
dB
dB
5
5
5
5
5
5
Output Voltage, IO = 40mA
Output Voltage, IO = 29mA
Stability/Noise
Slew Rate
Open Loop Gain
Common Mode Rejection
VO
VO
EN
SR
AOL
CMR
125°C
125°C
125°C
125°C
125°C
125°C
±45V
±150V
±150V
±150V
±150V
±32.5V
RL = 1K
40
RL = 5K
145
RL = 5K, AV = 1, CL = 10nF
1
RL = 5K
20
80
RL = 5K, F = 10Hz
96
RL = 5K, F = DC, VCM = ±22.5V
90
V
V
mV
V/µs
dB
dB
BURN IN CIRCUIT
TEMP. POWER
TEST CONDITIONS
*
100KΩ
+50V
100KΩ
5
*
**
*
2
U.U.T
6
7
1
60Ω
MIN
These components are used to stabilize device due
to poor high frequency characteristics of burn in
board.
** Input signals are calculated to result in internal power
dissipation of approximately 2.1W at case temperature
= 125°C.
–50V
PA83MU
http://www.cirrus.com
Copyright © Cirrus Logic, Inc. 2009
(All Rights Reserved)
SEP 2009
1
APEX − PA83MUREVH
PA83M/883
P r o d u c t I n n o v a t i o nF r o m
CONTACTING CIRRUS LOGIC SUPPORT
For all Apex Precision Power product questions and inquiries, call toll free 800-546-2739 in North America.
For inquiries via email, please contact [email protected].
International customers can also request support by contacting their local Cirrus Logic Sales Representative.
To find the one nearest to you, go to www.cirrus.com
IMPORTANT NOTICE
Cirrus Logic, Inc. and its subsidiaries ("Cirrus") believe that the information contained in this document is accurate and reliable. However, the information is subject
to change without notice and is provided "AS IS" without warranty of any kind (express or implied). Customers are advised to obtain the latest version of relevant
information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale
supplied at the time of order acknowledgment, including those pertaining to warranty, indemnification, and limitation of liability. No responsibility is assumed by Cirrus
for the use of this information, including use of this information as the basis for manufacture or sale of any items, or for infringement of patents or other rights of third
parties. This document is the property of Cirrus and by furnishing this information, Cirrus grants no license, express or implied under any patents, mask work rights,
copyrights, trademarks, trade secrets or other intellectual property rights. Cirrus owns the copyrights associated with the information contained herein and gives consent for copies to be made of the information only for use within your organization with respect to Cirrus integrated circuits or other products of Cirrus. This consent
does not extend to other copying such as copying for general distribution, advertising or promotional purposes, or for creating any work for resale.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). CIRRUS PRODUCTS ARE NOT DESIGNED, AUTHORIZED OR WARRANTED TO BE
SUITABLE FOR USE IN PRODUCTS SURGICALLY IMPLANTED INTO THE BODY, AUTOMOTIVE SAFETY OR SECURITY DEVICES, LIFE SUPPORT PRODUCTS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF CIRRUS PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER’S RISK AND CIRRUS DISCLAIMS AND MAKES NO WARRANTY, EXPRESS, STATUTORY OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, WITH REGARD TO ANY CIRRUS PRODUCT THAT IS USED IN SUCH A MANNER. IF THE
CUSTOMER OR CUSTOMER’S CUSTOMER USES OR PERMITS THE USE OF CIRRUS PRODUCTS IN CRITICAL APPLICATIONS, CUSTOMER AGREES,
BY SUCH USE, TO FULLY INDEMNIFY CIRRUS, ITS OFFICERS, DIRECTORS, EMPLOYEES, DISTRIBUTORS AND OTHER AGENTS FROM ANY AND ALL
LIABILITY, INCLUDING ATTORNEYS’ FEES AND COSTS, THAT MAY RESULT FROM OR ARISE IN CONNECTION WITH THESE USES.
Cirrus Logic, Cirrus, and the Cirrus Logic logo designs, Apex Precision Power, Apex and the Apex Precision Power logo designs are trademarks of Cirrus Logic, Inc.
All other brand and product names in this document may be trademarks or service marks of their respective owners.
2
PA83MU