CPI 3CW7000H3

The 3CW7000H3/Y-842A is a water cooled, ceramic/metal, medium-mu power triode designed
primarily for use in industrial radio frequency
heating services. Its water cooled anode is conservatively rated at 7 kW of plate dissipation with
low water flow and pressure drop. The tube is a
version of the air cooled 3CX4500F3 and is recommended for industrial applications where reserve
anode dissipation is required. Input of 25 kW is
permissible up to 75 MHz. Plentiful reserve emission is available from its 546 watt filament. The
grid structure is rated at 300 watts, making this
tube an excellent choice for industrial service.
Class of Operation
C
Characteristics
Plate Dissipation (Max.)
Screen Dissipation (Max.)
Grid Dissipation (Max.)
Frequency for Max. rating (CW)
Amplification Factor
Filament/Cathode
Voltage
Current
Capacitance
Input
Output
Feedthrough
Capacitance
Input
Output
Feedthrough
Cooling
Base
Air Socket
Air Chimney
Boiler
Length
Diameter
Weight
Maximum Ratings
Type of Service
Plate Voltage
(Volts)
Plate
Current
(Amps)
RF industrial oscillator or amplifier
9,000
3.0
T ypical Operation
Plate
Screen
Voltage Voltage
(Volts)
(Volts)
8,000
7,000 Watts
--300 Watts
75 MHz
22
Thoriated Tungsten
7.0 Volts
78.0 Amps
Grounded Cathode
35.0 pf
0.9 pf
20 pf
----- pf
--- pf
--- pf
Water and Forced Air
Flexible Leads
------12.56 in; 31.9 cm
3.63 in; 9.22 cm
4.4 lb; 2.0 kg
---
Plate
Current
(Amps)
2.75
Drive
Output
Power Power
(Watts) (kiloWatts)
710
15.0
The values listed above represent specified limits for the product and are subject to change. The data should be used for basic
information only. Formal, controlled specifications may be obtained from CPI for use in equipment design.
For information on this and other CPI products, visit our website at: www.cpii.com,
or contact: CPI MPP Division, Eimac Operations, 607 Hansen Way, Palo Alto, CA 94303
telephone : 1(800) 414-8823. fax : (650) 592-9988 | email : [email protected]
CPI | 3cW7000H3/ Y-842A
CPI | 4CW50,000J
3CW7000H3/Y-842A