The VTC-5764B pulsed-coupled cavity TWT covers 5.25 GHz to 5.75 GHz with 200 kW peak output power, 5.0 % duty cycle. This device has a non-intercepting grid pulsed and single stage depressed collector to achieve 47 dB gain. Custom configurations are also available. These variations in the performance and configuration include: cooling method (affects average power level), mechanical configuration, electrical and RF connections, & multiple stage depressed collector. Typical Operating Parameters Features • • • • • • • • • 5.25 GHz to 5.75 GHz 200 kW PEAK OUTPUT POWER 5.0 % DUTY CYCLE NON-INTERCEPTING GRID PULSED 47 dB GAIN SINGLE STAGE DEPRESSED COLLECTOR FORCED LIQUID COOLED SOLENOID FOCUSED COAXIAL INPUT, WR 187 WAVEGUIDE OUTPUT PARAMETER Cathode Voltage Cathode Current Heater Voltage Heater Current Collector Voltage Grid Bias Voltage Grid Pulse Voltage Solenoid Voltage Solenoid Current RF Drive Power Pulse Width Duty Cycle Cooling Flow Rate Pressure Drop Weight Dimensions MIN -50 --8 --37 -850 800 ----------14.0 ------- MAX -47 16 10 10 40 -750 1000 150 30 1.0 100 5.0 --50 400 14 Dia X 44 L The values listed above represent specified limits for the product and are subject to change. The data should be used for basic information only. Formal, controlled specifications may be obtained from CPI for use in equipment design. For additional information on CPI MPP products contact: CPI MPP, Coupled Cavity TWT Operation - 3120 Hansen Way, Palo Alto, CA 94303-0750 Phone: 650-846-3073, Fax: 650-857-1708, Email: [email protected], www.cpii.com/mpp UNITS kV a V A kV V v V A W µsec % gpm psig lbs inches