2.25 kW, CW Helix TWT Series, 5.85 GHz to 6.65 GHz, Periodic-Permanent, Magnet Focused, Coaxial Input, Waveguide Output, and Forced Air Cooled. Custom configurations are also available. These variations in the performance and configuration include: mechanical configuration, electrical and RF connections, & dual stage depressed collector. Model Number Frequency (GHz) Power Output (Min.) VTC-6369D5 VTC-6369D4 5.85 – 6.725 5.85 – 6.65 2.25 kW 2.25 kW Operating Parameters Features • • • • • • • • 2.25 k Watts 5.85 GHz – 6.65 GHz PPM Focusing Coaxial Input Waveguide Output Any Mounting Position Weight: 25 lbs. max Forced Air Cooled Heater Voltage Heater Surge Current Helix Voltage Collector Voltage 1 Collector Voltage 2 Collector Current 1 Parameters: Ef If Ew Eb1 Eb2 Ib1 Units: Maximum: Minimum: Typical: Vdc 6.6 6.0 A 5.0 --- kVdc 15.5 14.0 kVdc 0.67% Ew 0.63% Ew kVdc 0.32% Ew 0.28% Ew mAdc 990 --- Parameters: Units: Maximum: Minimum: Typical: Collector Current 2 Helix Current Drive Power Ib2 mAdc 650 --- Iw mAdc 25 --- Pd mW Adj. Adj. Cathode WarmUp Time tk minutes --3 Load VSWR Collector Temp. Air Flow 1.7:1 --- °C 150 --- Ib/hr --828 The values listed above represent specified limits for the product and are subject to change. The data should be used for basic information only. Formal, controlled specifications may be obtained from CPI for use in equipment design. For additional information on CPI MPP products contact: CPI MPP, Helix TWT Operation - 811 Hansen Way, Palo Alto, CA 94303-0750 Phone: 650-846-3900, Fax: 650-494-8779, Email: [email protected], www.cpii.com/mpp