CYNERGY3 FFSMC10AW10

FFSMC
3SERIES
high powerHIGHVOLTAGEREEDRELAYS
switch : turbulent liquid
TM
K67
4HE3SERIESWASDEVELOPEDFORTHEHIGHVOLTAGE
This is suitable for open reservoirs and
turbulent water and industrial wastewater.
!4%MARKETWHEREPRINTEDCIRCUITBOARD0#"
The switching element is self cleaning with 10
SPACEISATAPREMIUMTHE3SERIESHIGHVOLTAGE
Amp contacts, and makes the complete switch
REEDRELAYOFFERSAORK6ISOLATIONPERFORMANCE
insensitive to humidity and condensation,
INAMMSIZEPACKAGE7ITHLOWCONTACT
caused by wide tamperature fluctuations. The
RESISTANCETHE3SERIESISSUITABLEFORMANYHIGH
switch is fitted with additional internal weight,
VOLTAGEAPPLICATIONSAT$#ANDLOWFREQUENCY
such that it brings the centre of gravity and
rotation close to the cable entry.
WHEREPERFORMANCEANDRELIABILITYAREPARAMOUNT
-ECHANICAL$IMENSIONS
!LLDIMENSIONSAREINMILLIMETERSINCHES
USA
Cynergy3 Components 2320 Paseo de las Americas, Suite 104
53!San Diego, CA 92154
#YNERGY#OMPONENTS
Sales & Tech Support (866) 258-5057
Email: [email protected]
0ASEODELAS!MERICAS3UITE
3AN$IEGO#!
EUROPE - UK
3ALES4ECH3UPPORT
Cynergy3 Components Ltd.
%MAILSALES CYNERGYCOM
7 Cobham Road
Ferndown Industrial Estate
%52/0%5+
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
#YNERGY#OMPONENTS,TD
Fax +44 (0) 1202 891918 &AX
#OBHAM2OAD
Email:[email protected] %MAILSALES CYNERGYCOM
&ERNDOWN)NDUSTRIAL%STATE
7IMBORNE$ORSET"(0%
ISO 9001 C E R T I F I E D
)3/# % 24)&)%$ Operates in Turbulent Fluids
#OMPACT&OOTPRINT
Unaffected by Suspended Solids
$ESIGNED3PECIFICALLYFOR(IGH6OLTAGE
WRAS
approved
2HODIUM#ONTACTSFOR,OW2ESISTANCE
Cable
Mounting
ORK6
)SOLATION"ETWEEN#ONTACTS
100m
Depth Capability
%XCELLENT,IFETIME#HARACTERISTICS
Technical Specifications
#ONTACT
Switching Power Max.
5NITS
10 Amp
#ONDITIONS
K6&ORM!
AC
750 VA
K6&ORM!
#ONTACT-ATERIALS
2HODIUM
2HODIUM
DC
180W
)SOLATION!CROSS#ONTACTS
K6
$#OR!#PEAK
Switching
Current Max. Resistive
Resistive
-AX#ARRY#URRENT
!
$#OR!#RMS(Z
10 Amps
Switching
Voltage Max.
DC
110
-AX3WITCHING0OWER
7
-AX3WITCHING6OLTAGE
6
$#OR!#PEAK
AC
250
-AX3WITCHING#URRENT
!
$#OR!#PEAK
Switching Current Max. Inductive
AC
4A
#APACITANCE!CROSS#ONTACTS P&
#OIL3CREEN'ROUNDED
DC
1A
,IFETIME
/PERATIONS
$RY3WITCHING
Material
,IFETIMESpecifications
/PERATIONS
73WITCHING
Body
Material
High Density Polyethylene
#ONTACT2ESISTANCE
M/HMS
-AXIMUM4YPICAL
Cable
5 metres
PVC sheathed 3 Core
Standard
)NSULATION2ESISTANCE#ONTACT
/HMS
-INIMUM4YPICAL
WTO!LL/THER4ERMINALS
ƒ
cable for Drinking Water
WRAS approved 3 core cable
U#OILATƒ#
6
6
6
6
6
6
cable for Fuel Oils
Polyurethane sheathed 3 core cable
Temperature
-UST/PERATE
$#
0
range
°C 6
/ 55°C -UST2ELEASE
6
$#
°F
+ 32 / +131 Max.
/PERATE4IME
MS
$IODE&ITTED
working pressure
10bars It2ELEASE4IME
MS
$IODE&ITTED
is necessary to use an auxiliary relay, when switching pump motors or any loads that are not purely resistive. Part
2ESISTANCE
Numbering System for both/HMS
products
#ONSTRUCTION
FFSMC 10 A W 10
)SOLATION#ONTACTTO#OIL
K6
$#OR!#PEAK
length
in metres
TO!LL/THER4ERMINALS
/HMS
-INIMUM4YPICAL
Cable
Series
Blank = 5M standard
%NVIRONMENTALMax. current
Cable covering:
/PERATING4EMPERATURE2ANGE
ƒ#
TO
TO
Contact Form
A = n/o
B = n/c
0ART.UMBERING3YSTEM
C = c/o
2EEDSWITCH3IZE3
3
#ONTACT&ORM!&ORM!
Mechanical Dimensions
#ONTACT-ATERIAL22HODIUM
All dimensions are in millimeters (inches)
-OULDING2EFERENCE.UMBER
#OIL6OLTAGE615°
66
Off - On
)SOLATION"ETWEEN#ONTACTSK6Differential
K6
30°
15°
!
2
W = WRAS Approved
Blank = PVC
U = Polyurethane
N = Neoprene
S = Silicone
175mm
(6.9”)
On - Off
$#ONLY0IN(6
82mm
(3.2”)
Competitive part number cross-reference available at: WWWCYNERGYCOM
www.cynergy3.com
#OMPETITIVEPARTNUMBERCROSSREFERENCEAVAILABLEAT
© 2007 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Corp.
©#YNERGYCOMPONENTS!LL2IGHTS2ESERVED3PECIFICATIONSARESUBJECTTOCHANGEWITHOUTPRIORNOTICE#YNERGYCOMPONENTSANDTHE#YNERGYCOMPONENTSLOGOARETRADEMARKSOF#YNERGYCOMPONENTS#ORP