EMERSON-NETWORKPOWER PTH05050WAHT

Embedded Power for
Business-Critical Continuity
Rev.07.30.08
PTH05050
1 of 5
PTH05050
5 Vin
Single Output
Total Power:
21.6W
Input Voltage: 4.5 - 5.5VDC
# of Outputs: Single
Electrical Specifications
Output
Special Features
• 6 A output current
• 5 V input voltage
• Wide-output voltage adjust
(0.8 Vdc to 3.6 Vdc)
• Auto-track™ sequencing*
• Pre-bias start-up capability
• Efficiencies up to 95%
• Output ON/OFF inhibit
• Output voltage sense
• Point-of-Load-Alliance (POLA)
compatible
• Available RoHS compliant
• 2 Year Warranty
Voltage adjustability
0.8 - 3.6 Vdc
± 2.0% Vo
Line regulation
±10% mV typ.
Load regulation
±12 mV typ.
total regulation
± 3% Vo
Minimum load
Ripple and noise
20 MHz bandwidth
0A
20 mV pk-pk
Temperature co-efficient
-40°C to +85 °C
± 5% Vo
Transient response (see note 5)
70 μs recovery time
Overshoot/undershoot 100 MV
Input
Input voltage range
See note 3
4.5 - 5.5 Vdc
Input current
No load
10 mA typ.
Remote ON/OFF
See note 1
Positive logic
Startup time
1 V/ms
Undervoltage lockout
3.7 - 4.3 Vdc typ.
Track input voltage
Safety
(See note 4)
Setpoint accuracy
Pin 2 (See note 6, 7)
EMC Charateristics
UL/cUL CAN/CSA-C22.2
No. 60950-1-03/UL 60950-1,
File No. E186249
Electrostatic discharge
EN61000-4-2, IEC801-2
Conducted immunity
EN61000-4-6
TÜV Product Service (EN60950)
Certificate No.
B 06 07 38572 068
Radiated immunity
EN61000-4-3
± 0.3% Vin
Embedded Power for
Business-Critical Continuity
Rev.07.30.08
PTH05050
2 of 5
General Specifications
Efficiency
See Efficiency Table
95% max.
Insulation voltage
Non-isolated
Switching frequency
550 kHz to 650 Khz
Approvals and
standards
EN60950
UL/cUL60950
Material flammability
Dimensions
UL94V-0
(L x W x H)
22.10 x 12.57 x 8.50 mm
0.870 x 0.495 x 0.335 in.
Weight
2.9 g (0.10 oz)
MTBF demonstrated
Telcordia SR-332F
7,092,000 hours
Environmental Specifications
Thermal performance
(see note 2)
MSL ('Z' suffix only)
Operating ambient,
temperature
Non-operating
-40 °C to +85 °C
JEDEC J-STD-020C
Level 3
Auto reset
12 A typ.
-40 °C to +125 °C
Protection
Short-circuit
*Auto-track™ is a trade mark of Texas Instruments
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
Cin = 100 μF, Cout = 0 μF
Ordering Information
Regulation2
Output
Power
(Max.)
Input
Voltage
Output
Voltage
Output
Current
(Min.)
Output Current
(Max.)
Efficiency
(Typ.)
Line
Load
21.6 W
4.5 - 5.5 Vdc
0.8 - 3.6 V
0A
6A
95%
± 10 mV
± 12 mV
Model Number
PTH05050
Embedded Power for
Business-Critical Continuity
Rev.07.30.08
PTH05050
3 of 5
Part Number System with Options
Product Family
Input Voltage
Output
Current
Mechanical
Package
Output Voltage
Code
Pin Option (8)
Mounting Option (9)
Packaging Options
PTH
05
05
0
W
A
S
T
A = Through-Hole Std.
Pin Length (0.140")
A = Surface-mount
Tin/Lead Solder Ball
D = Horizontal Through-hole
(RoHS 6/6)
H = Horizontal Through-hole
(roHS 5/6)
S = Surface-mount
(RoHS 5/6)
Z = Surface-mount
(RoHS 6/6)
05 = 5 V
POLA
compatible
05 = 6 A
Always 0
W = Wide
Notes
No suffix = Trays
T = Tape and Reel
Output Voltage Adjustment of the PTH05050 Series
Remote ON/OFF. Positive Logic
ON:
Pin 3 open; or V > Vin - 0.5 V
OFF:
Pin 3 GND; or V < 0.8 V (min - 0.2 V).
2 See Figure 1 for safe operating curve.
3 A 100 μF electrolytic input capacitor is required for proper operation.
The capacitor must be rated for a minimum of 300 mA rms of ripple current.
4 An external output capacitor is not required for basic operation. Adding 100
μF of distributed capacitance at the load will improve the transient response.
5 1 A/μs load step, 50 to 100% Iomax, Cout = 100 μF.
6 If utilized Vout will track applied voltage by ±0.3 V (up to Vo set point).
7 The pre-bias start-up feature is not compatible with Auto-Track™. This is
because when the module is under Auto-Track™ control, it is fully active and
will sink current if the output voltage is below that of a back-feeding source.
Therefore to ensure a pre-bias hold-off, one of the following two techniques
must be followed when input power is first applied to the module. The AutoTrack™ function must either be disabled, or the module’s output held off using
the Inhibit pin. Refer to Application Note 158 for more details.
8 Tape and reel packaging only available on the surface-mount versions.
9 To order Pb-free (RoHS compatible) surface-mount parts replace the mounting
option ‘S’ with ‘Z’, e.g. PTH05050WAZ. To order Pb-free (RoHS compatible)
through-hole parts replace the mounting option ‘H’ with ‘D’, e.g.
PTH05050WAD.
10 NOTICE: Some models do not support all options. Please contact your local sales
representative or use the on-line model number search tool at
http://www.powerconversions.com to find a suitable alternative.
The ultra-wide output voltage trim range offers major advantages to users who
select the PTH05050. It is no longer necessary to purchase a variety of modules in
order to cover different output voltages. The output voltage can be trimmed in a
range of 0.8 Vdc to 3.6 Vdc. When the PTH05050 converter leaves the factory the
output has been adjusted to the default voltage of 0.8 V.
Efficiency Table (Io = 4 A)
Output Voltage
Vo
Vo
Vo
Vo
Vo
Vo
Vo
=
=
=
=
=
=
=
1.0
1.2
1.5
1.8
2.0
2.5
3.3
90
100
80
90
70
60
100LFM
Nat conv
50
40
EFFICIENCY (%)
TEMPERATURE (ºC)
1
Efficiency
V
V
V
V
V
V
V
85%
87%
89%
90%
91%
93%
95%
Vout
3.3V
2.5V
1.8V
80
70
1.2V
60
0.8V
50
40
30
0
1
2
3
4
5
20
0
1
2
3
4
5
6
OUTPUT CURRENT (A)
OUTPUT CURRENT (A)
Figure 1 - Safe Operating Area
Vin = 5 V, Output Voltage = 3.3 V (See Note A)
Figure 2 - Efficiency vs Load Current
Vin = 5 V (See Note B)
6
Embedded Power for
Business-Critical Continuity
Rev.07.30.08
PTH05050
4 of 5
Specifications
Notes
Track
1
Vout
6
B
2
Vin
PTH05050
(Top View)
3
SOA curves represent the conditions at which internal components are within
the Artesyn derating guidelines.
Characteristic data has been developed from actual products tested at 25 °C.
This data is considered typical data for the converter.
5
4
Cin 100F
(Required) +
A
Co1 100F
Electrolytic
(Optional)
RSET 1%, 0.1W
(Required)
+
Co2 10F
Ceramic
(Optional)
Inhibit
GND
GND
Figure 3 - Standard Application
0.140
(3.55)
0.870 (22.10)
0.060
(1.52)
0.125
(3.18)
0.125
(3.18)
0.040 (1.02)
6 Places
6
1
0.125
(3.18)
0.060
(1.52)
0.750 (19.06)
2
0.375 0.495
(12.57)
(9.52)
Lowest Component
0.010 min. (0.25)
Bottom side Clearance
3
5
4
0.070 (1.78)
(Standoff Shoulder)
TOP VIEW
0.335 (8.50)
MAX.
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
2 Places 0.030 (0.76)
3 Places 0.010 (0.25)
SIDE VIEW
Figure 4 - Plated Through-Hole Mechanical Drawing
Host Board
Embedded Power for
Business-Critical Continuity
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 (760) 930 4600
Facsimile: +1 (760) 930 0698
Specifications
0.870 (22.10)
0.060
(1.52)
0.060
(1.52)
0.750 (19.06)
2
0.125
(3.18)
0.125
(3.18)
max.*
*After solder reflow
on customer board
6
1
0.125
(3.18)
0.335 (8.50)
Solder Ball
0.040 (1.02)
6 Places
0.495
0.375 (12.57)
(9.52)
3
Rev.07.30.08
PTH05050
5 of 5
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
5
Asia (HK)
4
TOP VIEW
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
2 Places 0.030 (0.76)
3 Places 0.010 (0.25)
SIDE VIEW
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
technicalsupport@
powerconversion.com
Figure 5 - Surface-Mount Mechanical Drawing
Pin Connections
Pin No.
Function
1
2
3
4
5
6
Ground
Track
Vin
Inhibit*
Vo adjust
Vout
*Denotes negative logic:
Open = Normal operation
Ground = Function active
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2008 Emerson Electric Co.