ETAL P3034

PRODUCT DATA SHEET
LINE MATCHING TRANSFORMER
Features
Applications
∗
∗
∗
∗
∗
∗
∗
∗
∗
∗
∗
Low Distortion
Lead-free (Pb-free)
RoHS compliant
12.6mm (0.5") seated height
Vacuum encapsulated
IEC 60950 and UL 60950 Certified
UL Recognized Component
P3034
Telecommunications
V.34plus modems
Portable computers
Fax / modems
DESCRIPTION
P3034 is intended for V.34plus applications where
low distortion at moderate power levels is required
at a competitive price.
P3034 is a drop-in replacement for industry
standard P1200 for circuits to be upgraded to
V.34plus (33,600 bits/second). P3034 is also
mechanically and electrically compatible with P2001.
ETALDOC 458/10
Page 1 of 4
P3034 meets international safety standards,
being vacuum encapsulated and 100% tested to
withstand 6.5kV DC. The part is completely
lead-free, compliant with RoHS Directve
2002/95/EC, and suitable for lead-free and
conventional processing.
P3034 is certified to IEC 60950 and UL 60950.
P3034 is a UL Recognized Component and is
supported an IEC CB Test Certificate.
April 2005
P3034
SPECIFICATIONS
Electrical
At T = 25ºC and as circuit fig. 2 unless otherwise stated.
Parameter
Conditions
Min
Typ
Max
Units
Insertion Loss
f = 2kHz, RL = 560Ω
-
-
1.5
dB
Frequency response
LF-3dB cutoff
HF-3dB cutoff
200Hz - 4kHz
10
-
-
50
±0.2
Hz
kHz
dB
Return Loss
200Hz - 4kHz
18
-
-
dB
Third Harmonic
Distortion (1)
450Hz 0dBm in line
300Hz -10dBm
600Hz -10dBm
-
-78
–92
-105
-
dBm
dBm
dBm
Balance
DC – 5kHz
Method TG25
80
-
-
dB
Saturation
Excitation 50Hz
250V rms.
Output voltage
across line
-
-
10
65
Vrms
Vpeak
3.88
5.5
-
-
kVrms
kV
0
-40
-
+70
+125
ºC
ºC
120
-
148
Ω
14.5
-
19
mH
10mV 200Hz
4.5
6
-
H
10mV 200Hz
12
18
-
kΩ
Voltage
isolation (2)
50Hz
DC
Operating range:
Functional
Storage
Ambient temperature
Lumped equivalent circuit parameters as Fig. 1
DC resistance, RDC (3)
Sum of windings
Leakage inductance ΔL
Shunt inductance Lp
Shunt loss Rp (4)
(4)
Notes
Equivalent Circuit
1. Third harmonic typically exceeds other
harmonics by 20dB.
2. Components are 100% tested at 6.5kV DC.
3. Caution: do not pass DC through windings.
Telephone line current, etc. must be diverted
using choke or semiconductor line hold
circuit.
4. At signal levels greater than 100mV, Lp will
increase and Rp will decrease slightly but the
effect is usually favourable to the return loss
characteristic.
ETALDOC 458/10
Page 2 of 4
Fig. 1
½ L ½R
LINE
½R
½ L
IDEAL
1:1
EQUIPMENT
April 2005
P3034
MATCHING RECOMMENDATIONS
600Ω MATCH
EUROPEAN CTR21 COMPLEX MATCH
Recommended Circ uit
Recommended Circ uit
Fig. 2
Fig. 3
600
+ 50%
6.8μF _ 20% *
150nF
270
27nF
+_ 5%
LINE
33nF
+_ 5%
560
+_ 2%
2.2μF
(150nF)
100nF
56nF
750
(680)
750
150
(220)
LINE
* If return loss > 16dB, 300Hz - 4kHz is ac ceptable, bloc king
capacitor may be relaxed to 4.7μF +_ 50%
20%
Figure 3 gives flat RX and TX responses against the
CTR21 complex reference impedance (typically
around ±0.5dB 300Hz - 3.4kHz). Return loss is
typically better than 20dB. The circuit values in
parentheses give optimum flatness at a small
sacrifice in return loss.
For circuits with existing board drillings, figure 4
gives good return loss (>20dB) and RX flatness
against the CTR21 complex reference impedance,
but TX flatness is degraded by the use of this
topology.
Fig. 4
150nF
270
750
2.2μF
68nF
330
27nF
820
LINE
CONSTRUCTION
e2
Dimensions shown are in millimetres (inches).
Geometric centres of outline and pin grid coincide within a tolerance circle of 0.6mm
Windings may be used interchangeably as primary or secondary.
ETALDOC 458/10
Page 3 of 4
April 2005
P3034
SAFETY
CERTIFICATION
Constructed in accordance with IEC 60950-1,
EN 60950-1, supplementary insulation, and
UL 60950-1, reinforced insulation, 250Vrms
maximum working voltage, flammability class V-0.
Distances through solid insulation 0.4mm
minimum.
Certified under the IEC CB scheme (Certificate
DK-8570) to IEC 60950-1-2001, sub-clauses 1.5, 1.5.1,
1.5.2, 1.7.1, 2.9, 2.9.1, 2.9.2, 2.9.3, 2.10, 2.10.1, 2.10.2,
2.10.3, 2.10.3.1, 2.10.3.3, 2.10.4, 2.10.5, 2.10.5.1,
2.10.5.2, 2.10.5.4, 4.7, 4.7.1 (classV-1), 4.7.3, 4.7.3.1,
4.7.3.4, 5.2, 5.2.1, 5.2.2, 6.1.2.1 (Finland, Norway,
Sweden national deviations) for a maximum working
voltage of 250Vrms, nominal mains supply voltage not
exceeding 300Vrms and a maximum operating
temperature of 70ºC in Pollution Degree 2
environments, supplementary insulation.
Recognized under the Component Recognition
Program of Underwriters Laboratories Inc. to US and
Canadian
requirements
CAN/CSA
C22.2
No. 60950-1-03/UL60950-1, First Edition, based on
IEC 60950-1, First Edition, maximum working voltage
250Vrms, Pollution Degree 2, reinforced insulation.
UL File number E203175.
Additionally, Profec Technologies certifies all
transformers as providing voltage isolation of
3.88kVrms, 5.5kV DC minimum. All shipments are
supported by a certificate of conformity to current
applicable safety standards
ABSOLUTE MAXIMUM RATINGS
COPYRIGHT
(Ratings of components independent of circuit).
Short term isolation voltage (1s)
4.6kVrms,
6.5kV DC
DC current
100μA
Storage temperature
-40ºC to
+125ºC
Lead temperature, 10s
260ºC
ETAL, P1200, P2001 and P3034 are Trade Marks
of Profec Technologies Ltd.
The Trade Mark ETAL is registered at the UK
Trade Marks Registry.
Profec Technologies Ltd. is the owner of the
design right under the Copyright Designs and
Patents Act 1988 and no rights or licences are
hereby granted or implied to any third party.
© 1996 - 2005 Profec Technologies Ltd.
Reproduction prohibited.
E203175
ISO 9001
FM 25326
ETAL Group Oy, Kuormatie 14, FIN-03101, Nummela
Telephone: +358 (0)20 7500 330
Fax: +358 (0)20 7500 333
Website: www.etalgroup.com
Email: [email protected]
ETALDOC 458/10
Page 4 of 4
April 2005