FERROXCUBE EQ30-3F35

FERROXCUBE
DATA SHEET
EQ30
EQ cores and accessories
Supersedes data of September 2004
2008 Sep 01
Ferroxcube
EQ cores and accessories
EQ30
CORES
Effective core parameters of a set of EQ cores
SYMBOL
PARAMETER
VALUE
UNIT
Σ(I/A)
core factor (C1)
0.426
mm −1
Ve
effective volume
4970
mm 3
Ie
effective length
46.0
mm
Ae
effective area
108
mm 2
Amin
minimum area
95.0
mm 2
m
mass of core half
≈ 13.2
g
handbook,
5.3halfpage
handbook,
halfpage
8
±0.15
±0.2
30 ±0.4
26 ±0.4
19.45 ±0.4
11 ±0.2
20
±0.3
CBW562
Dimensions in mm.
Fig.1 EQ30 core.
Effective core parameters of an EQ/PLT combination
SYMBOL
PARAMETER
VALUE
UNIT
Σ(I/A)
core factor (C1)
0.335
mm −1
Ve
effective volume
3910
mm 3
Ie
effective length
36.2
mm
Ae
effective area
108
mm 2
Amin
minimum area
95.0
mm 2
m
mass of plate
≈ 7.6
g
handbook, halfpage
30 ± 0.4
2.7 ± 0.1
Ordering information for plates
GRADE
TYPE NUMBER
3C94
PLT30/20/3-3C94
3C95
PLT30/20/3-3C95
3C96
PLT30/20/3-3C96
3F35
PLT30/20/3-3F35
3F4
PLT30/20/3-3F4
3F45
PLT30/20/3-3F45
20 ± 0.3
MFP008
Dimensions in mm.
Fig.2 PLT30/20/3.
2008 Sep 01
2
Ferroxcube
EQ cores and accessories
EQ30
Core halves for use in combination with an EQ core
AL measured in combination with a non-gapped core half, clamping force for AL measurements, 40 ± 20 N.
GRADE
AL
(nH)
AIR GAP
(µm)
µe
TYPE NUMBER
3C94
5400 ± 25 %
≈ 1830
≈0
EQ30-3C94
3C95
6630 ± 25 %
≈ 2250
≈0
EQ30-3C95
3C96
4900 ± 25 %
≈ 1660
≈0
EQ30-3C96
3F35
3600 ± 25 %
≈ 1220
≈0
EQ30-3F35
3F4
2400 ± 25 %
≈ 814
≈0
EQ30-3F4
3F45
2400 ± 25 %
≈ 814
≈0
EQ30-3F45
Core halves for use in combination with a plate (PLT)
AL measured in combination with a plate (PLT), clamping force for AL measurements, 40 ± 20 N.
GRADE
AL
(nH)
AIR GAP
(µm)
µe
TYPE NUMBER
3C94
6550 ± 25 %
≈ 1750
≈0
EQ30-3C94
3C95
7960 ± 25 %
≈ 2120
≈0
EQ30-3C95
3C96
6000 ± 25 %
≈ 1600
≈0
EQ30-3C96
3F35
4600 ± 25 %
≈ 1225
≈0
EQ30-3F35
3F4
3200 ± 25 %
≈ 853
≈0
EQ30-3F4
3F45
3200 ± 25 %
≈ 853
≈0
EQ30-3F45
2008 Sep 01
3
Ferroxcube
EQ cores and accessories
EQ30
Properties of core sets under power conditions
B (mT) at
CORE
COMBINATION
CORE LOSS (W) at
H = 250 A/m;
f = 10 kHz;
T = 100 °C
f = 100 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 25 °C
f = 100 kHz;
ˆ = 200 mT;
B
T = 100 °C
f = 500 kHz;
ˆ = 50 mT;
B
T = 100 °C
EQ+EQ30-3C94
≥ 320
≤ 0.45
−
≤ 3.0
−
EQ+PLT30-3C94
≥ 320
≤ 0.35
−
≤ 2.3
−
EQ+EQ30-3C95
≥ 320
−
≤ 2.93
≤ 2.78
−
EQ+PLT30-3C95
≥ 320
−
≤ 2.3
≤ 2.2
−
EQ+EQ30-3C96
≥ 340
≤ 0.34
−
≤ 2.3
≤ 1.9
EQ+PLT30-3C96
≥ 340
≤ 0.23
−
≤ 1.7
≤ 1.4
EQ+EQ30-3F35
≥ 300
−
−
−
≤ 0.67
EQ+PLT30-3F35
≥ 300
−
−
−
≤ 0.52
Properties of core sets under power conditions (continued)
B (mT) at
CORE
COMBINATION
CORE LOSS (W) at
H = 250 A/m;
f = 10 kHz;
T = 100 °C
f = 500 kHz;
ˆ = 100 mT;
B
T = 100 °C
f = 1 MHz;
ˆ = 30 mT;
B
T = 100 °C
f = 1 MHz;
ˆ = 50 mT;
B
T = 100 °C
f = 3 MHz;
ˆ = 10 mT;
B
T = 100 °C
EQ+EQ30-3F35
≥ 300
≤ 5.2
−
−
−
EQ+PLT30-3F35
≥ 300
≤ 4.1
−
−
−
EQ+EQ30-3F4
≥ 300
−
≤ 1.5
−
≤ 2.4
EQ+PLT30-3F4
≥ 300
−
≤ 1.17
−
≤ 1.9
EQ+EQ30-3F45
≥ 300
−
≤ 1.15
≤ 4.3
≤ 2.0
EQ+PLT30-3F45
≥ 300
−
≤ 0.9
≤ 3.4
≤ 1.55
2008 Sep 01
4
Ferroxcube
EQ cores and accessories
EQ30
COIL FORMERS
General data
PARAMETER
SPECIFICATION
Coil former material
phenolformaldehyde (PF), glass reinforced, flame retardant
in accordance with “UL 94V-0”; UL file number E41429 (M)
Pin material
copper-clad steel, tin (Sn) plated
Maximum operating temperature
180 °C, “IEC 60085”, class H
Resistance to soldering heat
“IEC 60068-2-20” , Part 2, Test Tb, method 1B: 350 °C, 3.5 s
Solderability
“IEC 60068-2-20” , Part 2, Test Ta, method 1: 235 °C, 2 s
20 ±0.15
17.4 ±0.2
5 ±0.1
2.5 ±0.2
handbook, full pagewidth
4.5
±0.3
26.6
±0.15
21.3
±0.2
31
±0.2
25.6 0 20.3 +0.3 12.9
-0.2
0
±0.25
11.3 +0.2
0
5.5
±0.2
8.4
±0.2
16 ±0.3
29 ±0.3
CBW563
10
∅1.3
0
−0.2
Dimensions in mm.
Fig. 3 EQ30 coil former; 10-pins.
Winding data and area product for EQ30 coil former with 10 pins
NUMBER OF
SECTIONS
WINDING
AREA
(mm2)
MINIMUM
WINDING
WIDTH
(mm)
AVERAGE
LENGTH OF
TURN
(mm)
AREA
PRODUCT
Ae x Aw
(mm4)
1
52.0
8.2
60
5620
2008 Sep 01
5
TYPE NUMBER
CSV-EQ30-1S-10P
Ferroxcube
EQ cores and accessories
EQ30
DATA SHEET STATUS DEFINITIONS
DATA SHEET
STATUS
PRODUCT
STATUS
DEFINITIONS
Preliminary
specification
Development
This data sheet contains preliminary data. Ferroxcube reserves the right to
make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Ferroxcube reserves the right
to make changes at any time without notice in order to improve design and
supply the best possible product.
DISCLAIMER
Life support applications  These products are not designed for use in life support appliances, devices, or systems
where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube
for any damages resulting from such application.
PRODUCT STATUS DEFINITIONS
STATUS
INDICATION
DEFINITION
Prototype
These are products that have been made as development samples for the purposes of
technical evaluation only. The data for these types is provisional and is subject to
change.
Design-in
These products are recommended for new designs.
Preferred
These products are recommended for use in current designs and are available via our
sales channels.
Support
These products are not recommended for new designs and may not be available
through all of our sales channels. Customers are advised to check for availability.
2008 Sep 01
6