FERROXCUBE DATA SHEET PTS30/19/I PT, PTS, PTS/I cores and accessories Supersedes data of September 2004 2008 Sep 01 Ferroxcube PT, PTS, PTS/I cores and accessories PTS30/19/I CORE SETS 30 ± 0.5 Effective core parameters SYMBOL PARAMETER 25.4 ± 0.4 VALUE UNIT Σ(I/A) core factor (C1) 0.412 mm−1 Ve effective volume 5940 mm3 Ie effective length 49.5 mm Ae effective area 120 mm2 Amin minimum area 111 mm2 m mass of set ≈ 31 g 17.8 min 20.3 ± 0.25 13.3 ± 0.2 13.2 ± 0.2 18.8 ± 0.2 MFP058 Dimensions in mm. Fig.1 PTS30/19/I core set. Core sets for general purpose transformers and power applications Clamping force for AL measurements, 60 ± 20 N. AIR GAP (µm) AL (nH) µe 3C92 3830 ± 25 % ≈ 1260 ≈0 PTS30/19/I-3C92 3C94 5400 ± 25 % ≈ 1770 ≈0 PTS30/19/I-3C94 3C96 4840 ± 25 % ≈ 1590 ≈0 PTS30/19/I-3C96 GRADE TYPE NUMBER Properties of core sets under power conditions B (mT) at CORE LOSS (W) at H = 250 A/m; f = 25 kHz; T = 100 °C f = 100 kHz; ˆ = 100 mT; B T = 100 °C f = 100 kHz; ˆ = 200 mT; B T = 100 °C f = 500 kHz; ˆ = 50 mT; B T = 100 °C ≥ 320 ≤ 0.53 ≤ 3.5 − 3C94 ≥ 320 ≤ 0.53 ≤ 3.5 − 3C96 ≥ 315 ≤ 0.4 ≤ 2.7 ≤ 2.2 GRADE 3C92 BOBBINS AND ACCESSORIES For coil formers, winding data and mounting parts, see data sheet, “P30/19”. 2008 Sep 01 1074 Ferroxcube PT, PTS, PTS/I cores and accessories PTS30/19/I DATA SHEET STATUS DEFINITIONS DATA SHEET STATUS PRODUCT STATUS DEFINITIONS Preliminary specification Development This data sheet contains preliminary data. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. Product specification Production This data sheet contains final specifications. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. DISCLAIMER Life support applications These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube for any damages resulting from such application. PRODUCT STATUS DEFINITIONS STATUS INDICATION DEFINITION Prototype These are products that have been made as development samples for the purposes of technical evaluation only. The data for these types is provisional and is subject to change. Design-in These products are recommended for new designs. Preferred These products are recommended for use in current designs and are available via our sales channels. Support These products are not recommended for new designs and may not be available through all of our sales channels. Customers are advised to check for availability. 2008 Sep 01 1075