FERROXCUBE DATA SHEET U126/91/20 U, I cores and accessories Supersedes data of September 2004 2008 Sep 01 Ferroxcube U, I cores and accessories U126/91/20 U CORES Effective core parameters SYMBOL PARAMETER VALUE UNIT mm−1 Σ(I/A) core factor (C1) 0.857 Ve effective volume 268 800 mm3 Ie effective length 480 mm Ae effective area 560 mm2 Amin minimum area 560 mm2 m mass of core half ≈ 680 g 126 ± 4 handbook, halfpage 2 70 ± 2 63 ± 2 91 ± 1 20 ± 0.6 MFP073 Dimensions in mm. Fig.1 U126/91/20 core half. Core halves AL measured on a combination of 2 U cores. AL (nH) µe 3C90 3000 ± 25 % ≈ 2050 U126/91/20-3C90 3C94 3000 ± 25 % ≈ 2050 U126/91/20-3C94 GRADE TYPE NUMBER Properties of core sets under power conditions B (mT) at CORE LOSS (W) at H = 250 A/m; f = 25 kHz; T = 100 °C f = 25 kHz; ˆ B = 200 mT; T = 100 °C f = 100 kHz; ˆ = 100 mT; B T = 100 °C 3C90 ≥ 320 ≤ 35 ≤ 40 3C94 ≥ 320 − ≤ 32 GRADE 2008 Sep 01 1367 Ferroxcube U, I cores and accessories U126/91/20 DATA SHEET STATUS DEFINITIONS DATA SHEET STATUS PRODUCT STATUS DEFINITIONS Preliminary specification Development This data sheet contains preliminary data. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. Product specification Production This data sheet contains final specifications. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. DISCLAIMER Life support applications These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube for any damages resulting from such application. PRODUCT STATUS DEFINITIONS STATUS INDICATION DEFINITION Prototype These are products that have been made as development samples for the purposes of technical evaluation only. The data for these types is provisional and is subject to change. Design-in These products are recommended for new designs. Preferred These products are recommended for use in current designs and are available via our sales channels. Support These products are not recommended for new designs and may not be available through all of our sales channels. Customers are advised to check for availability. 2008 Sep 01 1368