FREQUENCYDEVICES D45

D45 Series
Fixed Frequency
Sinewave Oscillator
Description
The D45 Series are fixed frequency sinewave oscillators that deliver a single phase, high purity sinusoidal output. These fully finished devices can be
user specified to operate to any frequency between
100 Hz and 50.0 kHz.
Each D45 model includes provisions for the user to
adjust the output amplitude over a 1 to 20 Vp-p
range by external resistive or voltage programming.
Over the full output range, total harmonic distortion
is 0.1% to 0.3% based on frequency, while the
peak-to-peak amplitude stability of any fixed level
selected is 0.002 dB/°C.
Features/Benefits:
• Stable high purity sinewave output.
• Compact 1.8"L x 0.8"W x 0.3"H minimizes board
space requirements.
• Adjustable output amplitude for applications
requiring discrete or continuous output control.
• Plug-in ready-to-use, reducing engineering
design and manufacturing cycle time.
Applications
• Reference oscillator
• Airborne equipment
• Mobile equipment
• Test Apparatus
• Telemetry Systems
• Distortion Testing
1
1784 Chessie Lane, Ottawa, IL 61350 • Tel: 800/252-7074, 815/434-7800 • FAX: 815/434-8176
e-mail: [email protected] • Web Address: http://www.freqdev.com
D45 Series
Fixed Frequency
Sinewave Oscillator
FIXED FREQUENCY OPERATION
The output signal frequency of each D45 Series
sinewave oscillator is factory calibrated to within
±1% of the user-specified value. Independent of
frequency setting, the output amplitude is preset to
20V p-p.
Discrete Resistive Programming: The method
shown in Fig. 2(A) provides continuous control of
the output amplitude. For both methods, Equation
1 defines the value of R1 for the specific set of conditions.
T3
T3
METAL
FILM
To put the oscillator into operation, simply connect
the power supply common, voltages (±Vs), and
ground pin T2. Pin T2 must be connected to
ground in this mode of operation.
CERMET
R1
FINE FREQUENCY ADJUSTMENT (±5%)
For applications requiring a more accurate frequency setting, disconnect Pin T2 from ground. Connect
a Cermet potentiometer as shown in Fig. 1 for a
±5% frequency adjustment range.
GND
GND
(A)
(B)
Figure 2
R1(kΩ)=
T1
450VO
4VS-3VO
Equation 1
CERMET
500 ohm
VO = Output Voltage in V p-p
VS = Supply Voltage
Continuous Resistive Programming: To determine
the value of potentiometer R1 in Fig. 2(B), simply insert
the appropriate values into Equation 1.
GND
Suppose for example, the required output amplitude range is 1 to 10Vp-p and the positive power
supply is +Vs = 15 Vdc. At maximum output voltage
(10V p-p) equation 1 becomes
450 (10)
R1(kΩ)=
4(15)-3(10)
for potentiometer R1 = 150kΩ.
Voltage Programmable Amplitude: The output
amplitude of the D45 can be voltage controlled by
applying dc programming voltage VT3 to Pin T3. The
output response is found from Equation 2, below:
Figure 1
AMPLITUDE ADJUSTMENT (1 to 20V p-p)
For applications requiring either variable or lower
level output signals, a single resistor or a dc control
voltage can externally program the D45 output
amplitude to any value between 1 and 20V p-p.
Warning: Adjusting for outputs below 1Vp-p will
cause loss of the output signal.
VT3=
VO
2
Equation 2
2
where Vo is the output voltage expressed in Vp-p, and
VT3 is the dc control voltage applied to pin T3.
1784 Chessie Lane, Ottawa, IL 61350 • Tel: 800/252-7074, 815/434-7800 • FAX: 815/434-8176
e-mail: [email protected] • Web Address: http://www.freqdev.com
D45 Series
Pin-Out and Package Data
Ordering Information
Specifications
(25°C and Vs ± 15 Vdc)
Temperature
Operating
Storage
D45 Package OUTLINE
100 Hz to 50.0 kHz
±1%
±5%
0.80"(max)
Side View
0.30"(max)
0.15" (min)
0.025" (dia)
0.02%/°C
0.01%/%
1.80"(max)
Front View
20V p-p ± 1%
1 to 20V p-p
0.002 dB/°C
0.1 dB/%
All dimensions are in inches
All case dimensions ± 0.01"
0.80"
0.70"
T3
0.10"(typ)
T1
T2
GND
Bottom View
TERMINAL
±15 Vdc
±12 Vdc to ± 18 Vdc
±18 Vdc
±8 mA typ
±12 mA max.
V OUT
T1
T2
T3
+V s
GND
-V s
1.80"
1.30"
1.10"
0.40"
0.20"
0.1% (-60 dB)
0.2% (-53 dB)
0.3% (-50.4 dB)
50µV rms
OUT
+Vs
1.50"
1.60"
-Vs
0.10"
0.00"
0.80"
±5mA pk
<10 W
0.00"
Oscillation Frequency (fo)
Range
Tolerance 1
External Adjustment Range
Frequency Stability
Temperature
Supply/Output Amplitude Variation
Output Characteristics
Amplitude
Preset
Adjustment Range 2
Stability vs. Temperature 3
Stability vs. Supply Voltage 4
Drive Capacity
Output current @ 20V p-p 5
Output Resistance @ 20V p-p
Distortion 6
Harmonic
100 Hz to 10.0 kHz:
10.1 kHz to 25.0 kHz:
25.1 kHz to 50.0 kHz:
Noise
DC Power Supply (±Vs)
Rated Voltage
Operating Voltage Range
Maximum Safe Voltage
Quiescent Current
KEY
Signal Output
Fine Frequency Adjust
Frequency Adjust Enable*
Output Amplitude Adjust
Power Supply Voltage, Positive
Ground
Supply Voltage, Negative
*Must be connected to ground when fine frequency
adjustment is not required.
-20 to +70°C
-25 to +85°C
Notes:
1. Externally adjusted to zero.
2. All models can deliver 6V p-p into a 600 W load.
3. The amplitude stability of a resistively programmed unit is directly proportional to the external programming resistor temperature coef ficient.
4. The amplitude stability of a voltage programmed unit having the programming dc voltage applied to pin T3 is 0.1dB/%V T3.
5. The output is short circuit protected.
6. Distortion is primarily third harmonic. Specification is for resistive loading.
7. How to Specify Oscillation Frequency:
Oscillation frequencies are specified by attaching a three-digit frequency
designator to the basic model number. Oscillation frequencies can range
from 100 Hz to 50.0 kHz.
Ordering Information
D45-849 Hz
Oscillation Frequency 7
e.g., 849 Hz
25.0 kHz
50.0 kHz
We hope the information given here will be helpful. The information is based on data and our best knowledge, and we consider the information to be true and accurate. Please read all statements,
recommendations or suggestions herein in conjunction with our conditions of sale which apply to all goods supplied by us. W e assume no responsibility for the use of these statements,
recommendations or suggestions, nor do we intend them as a recommendation for any use which would infringe any patent or copyri ght.
PR-00D45-04
3
1784 Chessie Lane, Ottawa, IL 61350 • Tel: 800/252-7074, 815/434-7800 • FAX: 815/434-8176
e-mail: [email protected] • Web Address: http://www.freqdev.com