MRPR-3 Features and Benefits
Features
Benefits
Applications
• Miniature normally open switch
with 19.69mm x 2.84mm (0.775”
x 0.112”) glass envelope
• Switch contacts capable of
switching up to 1.5 Amps and
will carry up to 3 Amps
• Maximum contact rating 50
Watts
• Insulation resistance 1010 Ohms
• Available sensitivity range 22-43 AT
• Genuine power switching with a
miniature switch
• Hermetically sealed switch
contacts are not effected by and
have no effect on their external
environment
• Low, stable contact resistance
• Low space requirement
• Zero operating power required
for contact closure
• Fit and forget durability
•
•
•
•
•
Limit switching
Telephone line switching
Office equipment
Automotive applications
Light inductive loads
DIMENSIONS (in) mm
Switch Type
MRPR-3
Contact Form
A
Underwriters Laboratories Recognised, File E47258 (see note 1)
ELECTRICAL RATINGS
Contact Rating (2)
Watt - max.
50
Voltage
Switching
Breakdown
Vdc - max.
Vdc - min.
200
300
Current
Switching
Carry
A - max.
A - max.
1.5
3.0
Resistance
Contact, Initial
Insulation
Ω - max.
Ω - min.
0.100
1010
Capacitance
Contact
pF - typ.
Temperature
Operating
Storage (6)
°C
°C
0.2
-40 to +125
-65 to +125
OPERATING CHARACTERISTICS
Operate Time (3)
ms - max.
Release Time (3)
ms - max.
0.3
G - max.
100
Shock
11ms 1⁄2 sine wave
Vibration
50-2000 Hertz
0.75
G - max.
30
Hz - typ.
2100
Pull-In Range (4)
Ampere Turns
22-43
Rating Sensitivity (5)
Ampere Turns
Resonant Frequency
MAGNETIC CHARACTERISTICS
22
Test Coil
Notes
1)
2)
3)
L4989
For details on electrical specifications, contact Hamlin.
Contact rating-Product of the switching voltage and current should never exceed the
wattage rating.
Contact Hamlin for additional load/life information.
Operate (inc. bounce) /Release Time-per EIA/NARM RS421A, diode suppressed coil.
Hamlin USA
Hamlin UK
Hamlin Germany
Hamectrol France
Tel:
Tel:
Tel:
Tel:
4)
5)
6)
Pull in Range-Contact Hamlin for tolerances available within this range.
Rating Sensitivity-The value at which contact ratings and operating characteristics are
determined. Derating may be required below this value.
Storage Temperature-Long time exposure at elevated temperature may degrade
solderability of the leads.
+1 920 648 3000 • Fax: +1 920 648 3001 • Email: [email protected]
+44 (0)1379 649700 • Fax: +44 (0)1379 649702 • Email: [email protected]
+49 (0) 6142 923920 • Fax: +49 (0) 6142 923921 • Email: [email protected]
+33 (0) 1 6047 3000 • Fax: +33 (0) 1 6015 9136 • Email: [email protected]
INFORMATION PROVIDED ON THIS DATA SHEET IS PROVIDED FOR INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED UPON AS BEING ACCURATE FOR ANY
PARTICULAR PURPOSE. Product performance may be affected by the application to which the product is applied. Upon request, HAMLIN will assist purchasers by providing information
specific to any particular application. HAMLIN disclaims any and all liability whatsoever for any purchaser’s reliance upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
ISSUE No: 4 DATE: 1/5/3