HB 5VAC9DW6

+HEHL,76KDQJKDL&R/WG
SPECIFICATION
Part No. 9$&':
Features:
z High radiometric power per LED
z Very long operating life
(up to 100K hours)
z Low voltage DC operated
z More Energy Efficient than Incandescent
and most Halogen lamps
z Good color uniformity
z NO UV
z Superior ESD protection
z Easy installation with Screws
z High Heat dissipstion Efficiency
Typical Applications:
z Reading lights(car,bus,aircraft)
z Portable(flashlight,bicycle)
z Automotive Exterior(Stop-Tail-Turn,
CHMSL,Mirror Side Repeat)
z Decorative/Entertainment
z Dental curing lights
z Uplighters/Downlighters
NOTE:
z All dimensions are millimeter.
z Tolerance is ±0.1mm unless otherwise noted.
z It is strongly recommended that the temperature
of lead be not higher than 60℃.
z The appearance and specifications of the product
may be modified for improvement without notice.
z Bollards/Security/Garden
z Cove/Undershelf/Task
z Indoor/Outdoor Commercial and Residential Architectural
z Automotive Ext(stop-Tail-Turn)
z Street Lamp
ZZZOHG]FRP
Page 1 of 3
+HEHL,76KDQJKDL&R/WG
SPECIFICATION
Part No.9$&':
DIRECTIVITY
0°
Relative Luminous
1.0
Ta=25°C
IF=540mA
30°
60°
0.5
0
90°
60°
30°
0°
0.5
90°
1.0
Circuit Diagram:
X27 Row
A(+)
LED
LED
LED
LED
LED
LED
LED
LED
LED
LED
LED
LED
K(-)
ZZZOHG]FRP
Page 2 of 3
+HEHL,76KDQJKDL&R/WG
SPECIFICATION
Part No.:9$&':
Absolute maximum ratings(Ta = 25℃)
Value
Parameter
Symbol
Test
Condition
Unit
Min.
DC Forward Current
Peak Pulse Current
Power Dissipation
LED Junction Temperature
Operating Temperature
Storage Temperature
ESD Sensitivity
Soldering Temperature
IF
Ipeak
Pd
Tj
Topr
Tstr
-------
---Duty=0.1mS,1kHz
------------HBM
----
Max.
---700
mA
---1000
mA
---6.5
W
---120
℃
-25
+80
℃
-40
+100
℃
8000
---V
220℃ for 5 Seconds max
Electrical and optical characteristics (Ta = 25℃)
Value
Parameter
Symbol
Forward Voltage
Luminous Flux
Viewing Angle
VF
Φv
2θ1/2
Color Temperature
CCT
Test
Condition
Unit
Min.
Typ.
Max.
9.0
-------
9.2
410
120
10
-------
V
lm
Deg.
5000
----
8000
K
IF = 540mA
Luminous Flux Bins(Ta = 25℃)
Bin
Min
Max
W
320
360
X
360
400
Unit: lm
Y
400
450
Z
450
500
CCT Bins(Ta = 25℃)
Bin
Min
Max
W6
5000
5600
Unit: K
W7
5600
6300
W8
6300
7000
W9
7000
8000
Note
1. Flux is measured with an accuracy of ±15%
2. CCT is measured with an accuracy of ± 200K
3. Forward Voltage is measured with an accuracy of ± 0.15V
ZZZOHG]FRP
Page 3 of 3