HITRON HSU300

H HiTRON
DUAL SELECTABLE AC INPUT AC-DC 19" COMPATIBLE
DOUBLE EUROCARD MULTI-OUTPUT 300 WATTS
SWITCHING MODE POWER SUPPLIES HSU300 SERIES
FEATURES:
DUAL INPUT RANGE USER SELECTABLE
DOUBLE OR TRIPLE CONVERTER
ARCHITECTURE
19" COMPATIBLE EUROCARD FORMAT
MEET THE SAFETY STANDARDS
EMI MEET CISPR PUB. 22 & FCC CLASS A
CE MARKING COMPLIANCE
6U X 12HP X 160MM DOUBLE EUROCARD
VMEbus STANDARD
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: 115Vac/230Vac dual selectable.
Input Connector: DIN 41612.
Input Frequency: 47-63Hz
Inrush Current: Typ. 65A @230Vac.
Input Current: 1.2A@115Vac/0.7A@230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB. 22 & FCC Class A.
Power Fail/OK: Option.
Remote (Logic) Inhibit: Available.
Hold-up Time: Typ. 20mS.
Earth leakage: Typ. 0.3mA @230Vac.
Over Temperature Protection (OTP): Option.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ. 300 Watts.
Output Connector: DIN 41612 at rear.
Line Regulation: Typ. 0.4%.
Load Regulation: VO1 typ. ±1.0%(Main).
VO2 typ. ±1.0%(Main).
VO3 typ. ±1.0%(Main).
Noise & Ripple: Typ. 1% peak to peak.
OVP: Built-in at main VO1/VO2/VO3 (Latch).
Adjustability: Available at main output VO1,VO2,VO3.
Remote Sense: Installed at main VO1.
Overload Protection (OLP): Fully protected against
output overload and short circuit.
Consult factory for OLP setting.
GENERAL SPECIFICATION
Operating Temperature: 0 to +50°C at full load. Derates
linearly to +70°C at half load.
Switching Frequency: Typ. 100K Hz.
Storage Temperature: -20 to +85°C.
Circuit Topology: Forward circuit. Triple converter.
Temperature Coefficient: Typ. 0.04%/°C.
Transient Response: Typ. 3mS following a 25% load change. Cooling: At least 60cfm forced air flow is required
for full load.
Power Density: 1.90 Watts / Cubic Inch.
Construction format: 12HP(TE)x6Ux160mm
Safety Standard: IEC 60950-1/UL 60950-1 Class I.
19” compatible double Eurocard VMEbus standard.
Efficiency: Typ. 75-80.0%.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
In application
-57-
OUTPUT VOLTAGE / CURRENT RATINGS CHART
TRIPLE OUTPUT
MAIN VO1
Typ.
Volt.
MODEL NO.
HSU300-T050II
@#
Max.
Typ.
MAIN VO2 @
Max.
Volt.
MAIN VO3
Typ.
Volt.
@
Max.
36.0A
5.0V
40A
6.0A
12.0V
12A
6.0A
12.0V
12A
HSU300-T050KK
36.0A
5.0V
40A
5.0A
15.0V
10A
5.0A
15.0V
10A
HSU300-T050MI
36.0A
5.0V
40A
3.0A
24.0V
6A
6.0A
12.0V
12A
HSU300-T033II
50.0A
3.3V
55A
6.0A
12.0V
12A
6.0A
12.0V
12A
HSU300-T033EI
50.0A
3.3V
55A
15.0A
5.0V
--
6.0A
12.0V
12A
HSU300-T050DI
36.0A
5.0V
40A
18.0A
3.3V
--
6.0A
12.0V
12A
(HSU300-32)
Symbol: " " OVP built-in. "@" Adjustable. "#" Remote sensing.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 2.75kg (6.06 lb.)
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENTS
AC INPUT
ASSIGNMENT AC-L AC-N AC-G
TRIPLE OUTPUT
+VO1
+VO2
-VO3 DC COM
NC
P2-18,20,22 P1-8,10,12,24,16,18
CNTR &PIN# P1-28 P1-30 P1-32 P2-4,6,8,10,12 P2-28,30 P2-16
24,26
20,22,24,26
Mating connector: DIN41612-H15 Female
-58-
ASSORTED SIGNAL
SYS
S(+)
S(-)
AC Fail
Reset
P2-14
P2-32
P1-6
P1-4