MICROSEMI BAS40-04

BAS40
and
8700 E. Thomas Road
Scottsdale, AZ 85251
Tel: (480) 941-6300
Fax: (480) 947-1503
BAS70
SCHOTTKYarray™ SERIES
DESCRIPTION
Various configurations of Schottky barrier's diodes in SOT-23 packages are
provided for general-purpose use in high-speed switching, mixers and
detector applications. They may also be used for signal terminations at the
board level. This helps maintain signal integrity and counteract the
transmission-line effects with (PC) board traces by clamping over/and
undershoot from signal reflections with the schottky-low-threshold voltages.
This type of termination also does not depend on matching the transmission
line characteristic impedance, making it particularly useful where line
impedance is unknown or a variable. This method of termination can
control distortions of clock, data, address, and control lines as well as
provides a stabilizing effect on signal jitter. It can also significantly reduce
power consumption compared to standard resistor- based termination methods.
FEATURES
•
•
•
•
•
Protects from line to VCC and line to ground
Clamps within one forward diode threshold voltage
Low forward voltage and reverse recovery
characteristics
Bidirectional-low-forward available with “-04” suffix (Figure 2)
SOT-23 Surface Mount packaging for small foot print
•
•
•
Tape & Reel EIA Standard 481
7 inch reel 3,000 pieces
13 inch reel 10,000 pieces
MECHANICAL
MAXIMUM RATINGS
•
•
•
•
•
PACKAGING
•
•
•
Operating Temperatures: -550C to +1250C
Storage Temperature: -550C to +1500C
Power dissipation at Tamb = 250C is 200 mW
Forward Continuous Current at Tamb = 250C is 200 mA
Surge Forward Current At tp < 1 s, Tamb = 250C is 600 mA
Molded SOT-23 Surface Mount
Weight: .008 grams (approximate)
Body Marked with device number
ELECTRICAL CHARACTERISTICS PER DIODE @ 250C Unless otherwise specified
Repetitive
Peak Reverse
Voltage
DEVICE
TYPE
Reverse
Breakdown
Voltage
Tested with
10µA Pulse
DEVICE
FIGURE
MARKING
VRRM
(VOLTS)
V(BR)R
(VOLTS)
Leakage Current
Pulse test
tp < 300µs @
For BAS40
VR = 30 V
Forward Voltage Pulse Test
tp < 300µs
at IF = 1 mA
at IF = 40 mA
For BAS70
VR = 50 V
Reverse
Recovery
Time from
IF = 10 mA
through
IR=10mA to
IR=1mA
Thermal
Resistance
Junction to
Ambient Air
Capacitance
At VR = 0V
F = 1 MHz
Ctot
trr (ns)
RthJA (K/W)
pF
VF (mV)
IR (nA)
TYP
MIN
TYP
MAX
IF=1mA
MAX
MAX
MAX
BAS40
43
1
40
40
20
100
380
1000
5
430
5
BAS40-04
44
2
40
40
20
100
380
1000
5
430
5
BAS40-05
45
3
40
40
20
100
380
1000
5
430
5
BAS40-06
46
4
40
40
20
100
380
1000
5
430
5
BAS70
73
1
70
70
20
100
410
1000
5
430
2
BAS70-04
74
2
70
70
20
100
410
1000
5
430
2
BAS70-05
75
3
70
70
20
100
410
1000
5
430
2
BAS70-06
76
4
70
70
20
100
410
1000
5
430
2
MSC1380.PDF
IF=15mA IF=40mA
ISO 9001 CERTIFIED
REV C 2/02/2000
BAS40 and BAS70
Figure 1
Figure 2
Figure 3
Figure 4
PACKAGE OUTLINE
PAD DIMENSIONS
MSC1380.PDF ISO 9001 CERTIFIED
REV C 2/02/2000