JINANJINGHENG FR601

FR601 THRU FR607
R
FAST RECOVERY RECTIFIER
Reverse Voltage: 50 to 1000 Volts
Forward Current:6.0Amperes
S E M I C O N D U C T O R
R-6
FEATURES
Low leakage
Low forward voltage drop
JJF
High current capability
1.0(25.4)
MIN
High current surge
High reliability
High temperature soldering guaranteed:260°C/10 seconds at terminals
Component in accordance to RoHS 2002/95/EC and WEEE 2002/96/EC
0.360(9.1)
0.340(8.6)
DIA
0.360(9.1)
0.340(8.6)
MECHANICAL DATA
1.0(25.4)
MIN
Case: R-6 molded plastic body
Terminals: Plated axial leads, solderable per
MIL-STD-750,Method 2026
0.052(1.32)
0.048(1.22)
DIA
Polarity: Color band denotes cathode end
Mounting Position: Any
Dimensions in inches and (millimeters)
Weight: 0.074 OUNCE,2.08 grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating at 25 C ambient temperature unless otherwise specified.Single phase ,half wave ,60HZ,resistive or inductive
load. For capacitive load,derate current by 20%.)
Symbols
Maximum DC Blocking Voltage
VRRM
VRMS
VDC
Maximum Average Forward Rectified Current
0.375"(9.5mm)lead length at TA=55°C
Peak Forward Surge Current 8.3ms single half
sine-wave superimposed on rated load
(JEDEC method)
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum Instantaneous Forward Voltage
at 6.0A
Maximum DC Reverse Current
at rated DC blocking voltage
TA=25°C
FR
601
FR
602
FR
603
FR
604
FR
605
FR
606
FR
607
50
100
200
400
600
800
1000
35
70
140
280
420
560
700
50
100
200
400
600
800
1000
Typical junction capacitance(Note2)
Operating junction and storage temperature
range
Volts
Volts
Volts
I(AV)
6.0
Amps
IFSM
200
Amps
VF
1.2
Volts
10.0
IR
A
200
TA=100°C
Maximum reverse recovery time(Note1)
Units
trr
CJ
150
TJ TSTG
250
500
ns
100
pF
-65 to+150
C
Note: 1.Test conditions: IF=0.5A,IR=1.0A,IRR=0.25A.
2.Measured at 1MHZ and applied reverse voltage of 4.0 Volts D.C.
7-40
JINAN JINGHENG CO., LTD.
NO.51 HEPING ROAD JINAN P.R. CHINA TEL:86-531-86943657 FAX:86-531-86947096
WWW.JIFUSEMICON.COM
RATINGS AND CHARACTERISTIC CURVES FR601 THRU FR607
FIG.2-MAXIMUM NON-REPETITIVE
FORWARD SURGE CURRENT
8
SINGIE PHASE HAIF WAVE 60HZ
PEAK FORWARD SURGE CURRENT(AMPERES)
AVERAGE FORWARD CURRENT (A)
FIG.1-TYPICAL FORWARD CURRENT
DERATING CURVE
RESISTIVE OR INDUCTIVE LOAD
6
4
2
0
0
25
50
75
100
125
150
175
AMBIENT TEMPERATURE ( C)
FIG.3-TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
300
8.3ms SINGLE HALF SINE-WAVE
(JEDEC Method)
250
200
150
100
50
0
1
5
10
50
100
NUMBER OF CYCLES AT 60Hz
500
700
600
500
40
JUNCTION CAPACITANCE(pF)
INSTANTANEOUS FORWARD CURRENT(A)
FIG.4-TYPICAL JUNCTION CAPACITANCE
100
10
Tj=25°C
Pulse Width=300µs
1% Duty Cycle
1
400
300
200
100
60
40
1
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2
4
6
10
20
40
60
100
REVERSE VOLTAGE (V)
2.0
FORWARD VOLTAGE (V)
FIG.5-TEST CIRCUIT DIAGRAM AND REVERSE RECOVERY TIME CHARACTERISTIC
NONINDUCTIVE
NONINDUCTIVE
trr
+0.5A
(+)
D.U.T.
0
PULSE
GENERATOR
(NOTE2)
50Vdc
-0.25A
(ADJUSTABLE)
(-)
1
NONINDUCTIVE
OSCILLOSCOPE
(NOTE1)
-1.0A
1cm
SET TIME BASE FOR 50/100 ns/cm
NOTES:1.Rise Time=7ns max. input lmpedance=1
megohm 22pF
2.Rise Time=10ns max. source lmpedance=
50 ohms
7-41
JINAN JINGHENG CO., LTD.
NO.51 HEPING ROAD JINAN P.R. CHINA TEL:86-531-86943657 FAX:86-531-86947096