0233H SERIES The H version of the 0233 series filter offers good common and differential mode insertion loss in an extremely small package. This filter is well suited in applications where space is very limited. Operating Voltage = 115/250VAC Operating Current = 1,3, & 6 amperes Operating Frequency = 5060 Hz Operating Temperature = -20 to 50 deg. C Dielectric Withstanding (Line-Ground) = 1500 VDC for 1 minute Dielectric Withstanding (Line to Line) = 1500 VDC for 1 minutes Leakage Current = 0.5 mA @ 250 VAC, 50Hz Residual Voltage (Max after 5 sec.) = 34 Volts Agency Approvals UL, CSA, VDE USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 EUR JMK Inc Glasgow G13 1DN Scotland UK PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884