EA-0380-10A Operating Voltage = 115/250VAC Operating Current = 10 amperes Operating Frequency = 50/60 Hz Operating Temperature = -20 to 40 deg. C Dielectric Withstanding (Line-Ground) = 1500 VDC for 1 minute Dielectric Withstanding (Line to Line) = 1500 VDC for 1 minutes Leakage Current = 30uA @ 250 VAC, 50Hz Residual Voltage (Max after 5 sec.) = 32 Volts Agency Approvals UL, CSA The EF-0380-10A filter is a 10 amp single phase filter that can be used for both commercial and military applications where a LISN will be used to determine emission levels. The inlet connector is a standard IEC receptacle. USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 FX: 44-(0) 141 589 1884 EUR JMK Inc Glasgow G13 1DN Scotland UK