JMK FF-0221-5

0221 SERIES
The 221 Series is designed to provide commonmode and differential mode filtering for power
supply inputs ofcomputer peripheral and other
electronic hardware.
Operating voltage = 115/250 Vac
Operating current = 1, 2, 3, 5, 10 Amp
Operating frequency = 50/60Hz
Operating temperature = -20 to 50o C
Diel. withstanding (line - case) = 1500 Vac
Diel. withstanding (line - line) = 1500 Vdc
Leakage current = 0.5 ma at 250 Vac, 60 Hz
Max residual voltage after 1 sec. = 30 Volts
Agency approvals = UL, CSA
Ordering Information
AA-0221-X FF-0221-X ( X = Current required)
Use AA for (0.25) tab terms
Use FF for leads
DIMENSIONS (INCHES)
1, 2 AMP
3, 5 AMP
10 AMP
A
2.00
2.00
2.00
B
2.38
2.38
2.38
C
D
2.78 .87
2.78 1.13
2.78 1.13
E
1.75
1.75
2.00
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
EUR
JMK Inc Glasgow G13 1DN Scotland UK
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884