LAL2014-52 Broadband Access Transformer z z z Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation RoHS Compliant Operating Temperature -40°C to 85°C Electrical Specifications @25℃ OCL: PIN 16-9= 2.0mH ±10% @ 10KHz/0.1V/Ser. (PIN 11-14 Short) Leakage Inductance: PIN 1-4= 3.0uH Max. @ 100KHz/0.1V (PIN 2-3,5-6-7-8,9-11-14-16 Short) PIN 5-8= 20uH Max. @ 100KHz/0.1V (PIN 6-7,1-2-3-4,9-11-14-16 Short) PIN 1-16= 15pF Max. @ 100KHz/0.1V (PIN 2-3,PIN 11-14 Short) Interwinding Capacitance PIN 5-16= 15pF Max. @ 100KHz/0.1V (PIN 6-7,PIN 11-14 Short) PIN 1-8= 60pF Max. @ 100KHz/0.1V (PIN 2-3,PIN 6-7 Short) PIN 16-9 to PIN 1-4 –82dB Max. @ 30KHz/3.162V (PIN 11-14,PIN 2-3 Short) T.H.D PIN 16-9 to PIN 5-8= -82dB Max. @ 30KHz/3.162V (PIN 11-14,PIN 6-7 Short) PIN 16-9 = 1050 mohm Max. (PIN 11-14 Short) PIN 1-4 = 585 mohm Max. (PIN 2-3 Short) D.C.R PIN 5 -8 = 2.2 ohm Max. Hi-POT : (PIN 6-7 Short) PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA Turn Ratio: PIN16-9 : PIN 1-4 = 4.25±2% :1 ( PIN 11-14,PIN 2-3 Short) PIN16-9 : PIN 5-8 = 1±2% :1 ( PIN 11-14,PIN 6-7 Short) Dimensions (Units: mm) Schematic Mark LAL2014 LinkCom 1.LAL****----LAL2014 Date Code -52 G 2. X----PRODUCT LINE 3. DATE CODE----YYWW TOP VIEW Rev.F 4. G----RoHS SUGGESTED PADS LAYOUT