LINKCOM LAN1164-70

LAN1164-70
10/100BASE-Tx Magnetics Module
Meets IEEE 802.3 standard
RoHS Compliant
Quad port configuration
Design for 100base-Tx transmission over UTP-5 cable
Operating Temperature: 0℃~70℃
Electrical Specification @25℃
OCL:
Hi-POT :
31 TX3+
30 TX2+
29 TX228 CMGND
27 RX2+
26 RX2-
25 RX1-
24 RX1+
23 CMGND
22 TX1-
21 TX1+
TD2+ 11
TD2- 12
CT2 13
RD2+ 14
RD2- 15
RD1- 16
RD1+ 17
CT1 18
TD1- 19
TD1+ 20
36 RX4RD4- 5
TD3+ 10
39 TX438 CMGND
37 RX4+
TD4- 2
CT4 3
RD4+ 4
34 RX3+
33 CMGND
32 TX3-
40 TX4+
TD4+ 1
Schematic
RD3+ 7
CT3 8
TD3- 9
C.M.R.R.
Cross Talk :
35 RX3-
D.C.M.R. :
1:1±3%
0.9 ohm Max. @25°C
0.1-100MHz: -1.0dB Max.
2-30MHz
40MHz
50MHz
60-80MHz
-18dB Min.
-14.4dB Min.
-13.1dB Min.
-12 dB Min.
1-60MHz
60-200MHz
-40dB Min.
-30dB Min.
0.1~60MHz:-30dB Typ.
1MHz
30MHz
60MHz
100MHz
-55dB Min.
-45dB Min.
-40dB Min.
-33dB Min.
RD3- 6
Turn Ratio:
D.C.R:
Insertion Loss
Return Loss:
350uH Min.@100KHz/0.1V with 8mA DC Bias
1500Vrms
Dimensions
16.4
28.0±0.25
SUGGESTED LAND PATTERN
Units: mm
i
Unless otherwise specified, all tolerances are ±0.25
Ver. A