LITEON LTL2H3HRKL13

LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
+
Features
* Lead (Pb) free product – RoHS compliant.
* High luminous intensity output.
* Low power consumption.
* High efficiency.
* Versatile mounting on P.C. board or panel.
* I.C. Compatible/low current requirements.
* Popular T-13/4 diameter.
Package Dimensions
Part No.
Lens
Source Color
LTL2H3HRKL13
Water Clear
AlInGaP Super Red
Notes:
1. All dimensions are in millimeters (inches).
2. Tolerance is ±0.25mm(.010") unless otherwise noted.
3. Protruded resin under flange is 1.0mm(.04") max.
4. Lead spacing is measured where the leads emerge from the package.
5. Specifications are subject to change without notice.
Part No. : LTL2H3HRKL13 FOR ARROW - TTS
BNS-OD-C131/A4
Page :
1
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
o
Absolute Maximum Ratings at TA=25 C
Parameter
Power Dissipation
Maximum Rating
Unit
125
mW
100
mA
50
mA
0.6
mA/ C
5
V
Peak Forward Current
(1/10 Duty Cycle, 0.1ms Pulse Width)
DC Forward Current
o
Derating Linear From 30 C
Reverse Voltage
Operating Temperature Range
Storage Temperature Range
o
o
o
-40 C to + 80 C
o
o
-55 C to + 100 C
Lead Soldering Temperature
[ 2mm (.0787") From Body]
Part No. : LTL2H3HRKL13 FOR ARROW - TTS
BNS-OD-C131/A4
260°C for 5 Seconds
Page :
2
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
o
Electrical / Optical Characteristics at TA=25 C
Parameter
Symbol
Min.
Typ.
IV
9300
12000
mcd
2θ1/2
15
deg
Peak Emission Wavelength
λP
639
nm
Dominant Wavelength
λd
Spectral Line Half-Width
∆λ
17
Forward Voltage
VF
2.2
Reverse Current
IR
Capacitance
C
Luminous Intensity
Viewing Angle
620
625
40
Max.
630
Unit
nm
Test Condition
IF = 20mA
Note 1,5
Note 2 (Fig.5)
Measurement
@Peak (Fig.1)
Note 4
nm
2.3
V
IF = 20mA
100
µA
VR = 5V
pF
VF = 0 , f = 1MHz
NOTE: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
eye-response curve.
2. θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. The dominant wavelength, λd is derived from the CIE chromaticity diagram and represents the single
wavelength which defines the color of the device.
4. Iv classification code is marked on each packing bag.
5. The Iv guarantee should be added ±15% tolerance.
Part No. : LTL2H3HRKL13 FOR ARROW - TTS
BNS-OD-C131/A4
Page :
3
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Typical Electrical / Optical Characteristics Curves
o
(25 C Ambient Temperature Unless Otherwise Noted)
Part No. : LTL2H3HRKL13 FOR ARROW - TTS
BNS-OD-C131/A4
Page :
4
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Packing Spec
2 reel per inner carton
total 2000pcs per inner carton
6 Inner cartons per outer carton
total 12000 pcs per outer carton
In every shipping lot, only the last pack will be non-full packing.
Part No. : LTL2H3HRKL13 FOR ARROW - TTS
BNS-OD-C131/A4
Page :
5
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Bin Table Specification
Luminous Intensity Iv(mcd)
IF@20mA
Bin Code
Min.
Max.
Y
9300
12000
Z
12000
16000
5A
16000
21000
Note: Tolerance of measurement precision is ±15%
Forward Voltage Vf (Volts)
IF@20mA
Bin Code
Min.
Max.
1
1.8
1.9
2
1.9
2.0
3
2.0
2.1
4
2.1
2.2
5
2.2
2.3
Note: Tolerance of measurement precision is ±0.01 V
Part No. : LTL2H3HRKL13 FOR ARROW - TTS
BNS-OD-C131/A4
Page :
6
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
CAUTIONS
1. Application
The LEDs described here are intended to be used for ordinary electronic equipment (such as office
equipment,
communication equipment and household applications).Consult Liteon’s Sales in advance
for information on applications in which exceptional reliability is required, particularly when the failure or
malfunction of the LEDs may directly jeopardize life or health (such as in aviation, transportation, traffic
control equipment, medical and life support systems and safety devices).
2. Storage
The storage ambient for the LEDs should not exceed 30°C temperature or 70% relative humidity.
It is recommended that LEDs out of their original packaging are used within three months.
For extended storage out of their original packaging, it is recommended that the LEDs be stored
in a sealed container with appropriate desiccant or in desiccators with nitrogen ambient.
3. Cleaning
Use alcohol-based cleaning solvents such as isopropyl alcohol to clean the LEDs if necessary.
4. Lead Forming & Assembly
During lead forming, the leads should be bent at a point at least 3mm from the base of LED lens.
Do not use the base of the lead frame as a fulcrum during forming.
Lead forming must be done before soldering, at normal temperature.
During assembly on PCB, use minimum clinch force possible to avoid excessive mechanical stress.
5. Soldering
When soldering, leave a minimum of 2mm clearance from the base of the lens to the soldering point.
Dipping the lens into the solder must be avoided.
Do not apply any external stress to the lead frame during soldering while the LED is at high temperature.
Recommended soldering conditions :
Soldering iron
Temperature
Soldering time
300°C Max.
3 sec. Max.
(one time only)
Wave soldering
Pre-heat
Pre-heat time
Solder wave
Soldering time
100°C Max.
60 sec. Max.
260°C Max.
5 sec. Max.
Note: Excessive soldering temperature and/or time might result in deformation of the LED lens or catastrophic
failure of the LED. IR reflow is not suitable process for through hole type LED lamp product.
Part No. : LTL2H3HRKL13 FOR ARROW - TTS
BNS-OD-C131/A4
Page :
7
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
6. Drive Method
An LED is a current-operated device. In order to ensure intensity uniformity on multiple LEDs
connected in parallel in an application, it is recommended that a current limiting resistor be
incorporated in the drive circuit, in series with each LED as shown in Circuit A below.
Circuit model A
LED
Circuit model B
LED
(A) Recommended circuit
(B) The brightness of each LED might appear different due to the differences in the I-V characteristics
of those LEDs
7. ESD (Electrostatic Discharge)
Static Electricity or power surge will damage the LED.
Suggestions to prevent ESD damage:
Use a conductive wrist band or anti- electrostatic glove when handling these LEDs
All devices, equipment, and machinery must be properly grounded
Work tables, storage racks, etc. should be properly grounded
Use ion blower to neutralize the static charge which might have built up on surface of the LEDs
plastic lens as a result of friction between LEDs during storage and handing
Part No. : LTL2H3HRKL13 FOR ARROW - TTS
BNS-OD-C131/A4
Page : 8
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Suggested checking list :
Training and Certification
1. Everyone working in a static-safe area is ESD-certified?
2. Training records kept and re-certification dates monitored?
Static-Safe Workstation & Work Areas
1. Static-safe workstation or work-areas have ESD signs?
2. All surfaces and objects at all static-safe workstation and within 1 ft measure less than 100V?
3. All ionizer activated, positioned towards the units?
4. Each work surface mats grounding is good?
Personnel Grounding
1. Every person (including visitors) handling ESD sensitive (ESDS) items wear wrist strap, heel strap or
conductive shoes with conductive flooring?
2. If conductive footwear used, conductive flooring also present where operator stand or walk?
3. Garments, hairs or anything closer than 1 ft to ESD items measure less than 100V*?
4. Every wrist strap or heel strap/conductive shoes checked daily and result recorded for all DLs?
5. All wrist strap or heel strap checkers calibration up to date?
Note: *50V for Blue LED.
Device Handling
1. Every ESDS items identified by EIA-471 labels on item or packaging?
2. All ESDS items completely inside properly closed static-shielding containers when not at static-safe
workstation?
3. No static charge generators (e.g. plastics) inside shielding containers with ESDS items?
4. All flexible conductive and dissipative package materials inspected before reuse or recycle?
Others
1. Audit result reported to entity ESD control coordinator?
2. Corrective action from previous audits completed?
3. Are audit records complete and on file?
Part No. : LTL2H3HRKL13 FOR ARROW - TTS
BNS-OD-C131/A4
Page :
9
of
10
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
8. Reliability Test
Classification
Test Item
Operation Life
Endurance
Test
Test Condition
Reference Standard
Ta= Under Room Temperature As
Per Data Sheet Maximum Rating
*Test Time= 1000HRS (-24HRS,+72HRS)
o
MIL-STD-750D:1026 (1995)
MIL-STD-883D:1005 (1991)
JIS C 7021:B-1 (1982)
High Temperature
High Humidity
Storage
Ta= 65±5 C
RH= 90 ~ 95%
High Temperature
Storage
Ta= 105±5 C
*Test Time= 1000HRS (-24HRS,+72HRS)
Low Temperature
Storage
Ta= -55±5 C
*Test Time=1000HRS (-24HRS,+72HRS)
Temperature
Cycling
105 C ~ 25 C ~ -55 C ~ 25 C
30mins 5mins
30mins 5mins
10 Cycles
Thermal
Shock
105 ± 5 C ~ -55 C ± 5 C
10mins
10mins
10 Cycles
Solder
Resistance
T.sol = 260 C
Dwell Time= 5 secs Max
MIL-STD-202F:210A(1980)
MIL-STD-750D:2031(1995)
JIS C 7021: A-1(1982)
T. sol = 230± 5°C
Dwell Time= 5 secs Max
MIL-STD-202F:208D(1980)
MIL-STD-750D:2026(1995)
MIL-STD-883D:2003(1991)
JIS C 7021: A-2(1982)
Test Time= 240HRS±2HRS
o
o
o
Solderability
MIL-STD-883D:1008 (1991)
JIS C 7021:B-10 (1982)
o
o
Environmental
Test
MIL-STD-202F: 103B(1980)
JIS C 7021 : B-11(1982)
o
o
o
o
o
JIS C 7021:B-12 (1982)
MIL-STD-202F:107D (1980)
MIL-STD-750D:1051(1995)
MIL-STD-883D:1010 (1991)
JIS C 7021: A-4(1982)
MIL-STD-202F:107D(1980)
MIL-STD-750D:1051(1995)
MIL-STD-883D:1011 (1991)
9. Others
The appearance and specifications of the product may be modified for improvement, without prior notice.
Part No. : LTL2H3HRKL13 FOR ARROW - TTS
BNS-OD-C131/A4
Page :
10
of
10