LITEON LTW-006DCG-E2

LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Features
* Package in 12mm tape on 7" diameter reels.
* Compatible with automatic placement equipment.
* Compatible with infrared and vapor phase reflow solder process.
* EIA STD package.
* I.C. compatible.
* Meet green product and Pb-free(According to RoHS)
Package
Dimensions
Anode
Part No.
Lens Color
Source Color
LTW-006DCG-E2
Yellow
InGaN White
Notes:
1. All dimensions are in millimeters (inches).
2. Tolerance is ±0.1 mm (.004") unless otherwise noted.
Part No. : LTW-006DCG-E2
BNS-OD-C131/A4
Page :
1
of
11
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
℃
Absolute Maximum Ratings at Ta=25℃
Parameter
LTW-006DCG-E2
Unit
120
mW
(1/10 Duty Cycle, 0.1ms Pulse Width)
100
mA
DC Forward Current
30
mA
Reverse Voltage
5
V
Power Dissipation
Peak Forward Current
Operating Temperature Range
-30℃ to + 85℃
Storage Temperature Range
-40℃ to + 100℃
Reflow Soldering Condition
260℃ For 10 Seconds
Suggest IR Reflow Condition :
R-Reflow Soldering Profile for lead free soldering (Acc. to J-STD-020B)
Part No. : LTW-006DCG-E2
BNS-OD-C131/A4
Page :
2
of
11
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Electrical
Optical
Characteristics
Parameter
Ta=25℃
℃
Symbol
Part No.
LTW-
Min.
IV
006DCG-E2
1700
2θ1/2
006DCG-E2
Luminous Intensity
Viewing Angle
At
Max.
Unit
Test Condition
2100
mcd
IF = 20mA
Note 1, 2, 5
deg
Fig.6
110
x
Chromaticity Coordinates
Typ.
IF = 20mA
Note 3, 5
Fig.1
0.277
006DCG-E2
y
0.255
Forward Voltage
VF
006DCG-E2
3.0
ESD-Withstand Voltage
ESD
006DCG-E2
200V
3.5
V
IF = 20mA
V
HBM
Note : 1. Luminous intensity is measured with a light sensor and filter combination that approximates the
CIE eye-response curve.
2. Iv classification code is marked on each packing bag.
3. The chromaticity coordinates (x, y) is derived from the 1931 CIE chromaticity diagram.
4. Caution in ESD:
Static Electricity and surge damages the LED. It is recommend to use a wrist band or
anti-E2lectrostatic glove when handling the LED. All devices, equipment and machinery
must be properly grounded.
5. CAS140B-1 is the test standard for the chromaticity coordinates (x, y) & IV.
6. The chromaticity coordinates (x, y) guarantee should be added +/- 0.007 tolerance.
Part
No. : LTW-006DCG-E2
BNS-OD-C131/A4
Page :
3
of
11
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Bin Code List
VF Spec. Table
VF Bin
Forward Voltage (V) at IF = 20mA
Min.
Max.
V0
2.9
3.0
V1
3.0
3.1
V2
3.1
3.2
V3
3.2
3.3
V4
3.3
3.4
V5
3.4
3.5
V6
3.5
3.6
Tolerance on each Forward Voltage bin is +/-0.10 volt
IV Spec. Table
Luminous Intensity (mcd) at IF = 20mA
IV Bin
Min.
Max.
S81
1700
1750
S82
1750
1800
S91
1800
1850
S92
1850
1900
101
1900
1950
102
1950
2000
111
2000
2050
112
2050
2100
Tolerance on each Luminous Intensity bin is +/- 7%.
Part
No. : LTW-006DCG-E2
BNS-OD-C131/A4
Page :
4
of
11
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Color Ranks Table
Color bin limits at IF = 20mA
Ranks
C12
C21
C22
C31
C32
B12
B21
B22
B31
B32
CIE 1931Chromaticity coordinates
x
0.265
0.27
0.27
0.265
y
0.237
0.245
0.258
0.25
x
0.27
0.275
0.275
0.27
y
0.245
0.253
0.266
0.258
x
0.275
0.28
0.28
0.275
y
0.253
0.261
0.274
0.266
x
0.28
0.285
0.285
0.28
y
0.261
0.269
0.282
0.274
x
0.285
0.29
0.29
0.285
y
0.269
0.277
0.29
0.282
x
0.265
0.27
0.27
0.265
y
0.224
0.232
0.245
0.237
x
0.27
0.275
0.275
0.27
y
0.232
0.24
0.253
0.245
x
0.275
0.28
0.28
0.275
y
0.24
0.248
0.261
0.253
x
0.28
0.285
0.285
0.28
y
0.248
0.256
0.269
0.261
x
0.285
0.29
0.29
0.285
y
0.256
0.264
0.277
0.269
Tolerance on each Hue (x, y) bin is +/- 0.007.
* Color Coordinates Measurement allowance is ±0.007
Part
No. : LTW-006DCG-E2
BNS-OD-C131/A4
Page :
5
of
11
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Typical Electrical / Optical Characteristics Curves
(25°° C Ambient Temperature Unless Otherwise Noted)
Part No. : LTW-006DCG-E2
BNS-OD-C131/A4
Page :
6
of
11
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
User Guide
Cleaning
Do not use unspecified chemical liquid to clean LED they could harm the package.
If cleaning is necessary, immerse the LED in ethyl alcohol or isopropyl alcohol at
normal temperature for less one minute.
Recommend Printed Circuit Board Attachment Pad
Infrared / vapor phase
Reflow Soldering
Package Dimensions of Tape
Note:
1.All dimensions are in millimeters (inches).
Part No. : LTW-006DCG-E2
BNS-OD-C131/A4
Page :
7
of
11
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Package Dimensions of Reel
Notes:
1. Empty component pockets sealed with top cover tape.
2. 7 inch reel-2000 pieces per reel.
3. The maximum number of consecutive missing lamps is two.
4. In accordance with EIA-481-1-E2 specifications.
Part No. : LTW-006DCG-E2
BNS-OD-C131/A4
Page :
8
of
11
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
CAUTIONS
1. Application
The LEDs described here are intended to be used for ordinary electronic equipment (such as office
equipment, communication equipment and household applications).Consult Liteon’s Sales in advance for
information on applications in which exceptional reliability is required, particularly when the failure or
malfunction of the LEDs may directly jeopardize life or health (such as in aviation, transportation, traffic
control equipment, medical and life support systems and safety devices).
2. Storage
This product is qualified as Moisture sensitive Level 3 per JEDEC J-STD-020 Precaution when handing
this moisture sensitive product is important to ensure the reliability of the product.
The package is sealed:
The LEDs should be stored at 30°C or less and 90%RH or less. And the LEDs are limited to use
within one year, while the LEDs is packed in moisture-proof package with the desiccants inside.
The package is opened:
The LEDs should be stored at 30°C or less and 60%RH or less. Moreover, the LEDs are limited to
solder process within 168hrs. If the Humidity Indicator shows the pink color in 10% even higher or
exceed the storage limiting time since opened, that we recommended to baking LEDs at 60°C at
least 48hrs. To seal the remainder LEDs return to package, it’s recommended to be with workable
desiccants in original package.
3. Cleaning
Use alcohol-based cleaning solvents such as isopropyl alcohol to clean the LED if necessary.
4. Soldering
Recommended soldering conditions:
Reflow soldering
Pre-heat
Pre-heat time
Peak temperature
Soldering time
120~150°C
120 sec. Max.
260°C Max.
30 sec. Max.
Soldering iron
Temperature
300°C Max.
Soldering time 3 sec. Max.
(one time only)
5. Drive Method
An LED is a current-operated device. In order to ensure intensity uniformity on multiple LEDs connected
in parallel in an application, it is recommended that a current limiting resistor be incorporated in the drive
circuit, in series with each LED as shown in Circuit A below.
Circuit model A
LED
Circuit model B
LED
(A) Recommended circuit.
(B) The brightness of each LED might appear different due to the differences in the I-V characteristics
of those LEDs.
Part
No. : LTW-006DCG-E2
BNS-OD-C131/A4
Page :
9
of
11
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
6. ESD (Electrostatic Discharge)
Static Electricity or power surge will damage the LED. Suggestions to prevent ESD damage:
Use of a conductive wrist band or anti-E2lectrostatic glove when handling these LEDs.
All devices, equipment, and machinery must be properly grounded.
Work tables, storage racks, etc. should be properly grounded.
Use ion blower to neutralize the static charge which might have built up on surface of the LED’s plastic
lens as a result of friction between LEDs during storage and handling.
ESD-damaged LEDs will exhibit abnormal characteristics such as high reverse leakage current, low forward
voltage, or “ no lightup ” at low currents.
To verify for ESD damage, check for “ lightup ” and Vf of the suspect LEDs at low currents.
The Vf of “ good ” LEDs should be >[email protected] for InGaN product
7.1 Reliability Test
Test Item
Test Condition
Reference Standard
Note
Number of
Damaged
Resistance to Soldering
Heat (Reflow Soldering)
Tsld=260℃, 10sec.
JEITA ED-4701
300 301
2 times
0/50
Solderability
(Reflow Soldering)
Tsld=245±5℃, 3sec.
(Lead Free Solder)
JEITA ED-4701
300 303
1 time
Over 95%
0/50
Thermal Shock
-30℃ ~ 85℃
30min. 30min.
JEITA ED-4701
300 307
100 cycles
0/50
Temperature Cycle
-40℃ ~ 25℃ ~ 100℃ ~ 25℃
30min. 5min. 30min. 5min.
JEITA ED-4701
100 105
100 cycles
0/50
High Temperature Storage
Ta=100℃
JEITA ED-4701
200 201
1000 hrs.
0/50
Temperature Humidity
Storage
Ta=60℃, RH=90%
JEITA ED-4701
100 103
1000 hrs.
0/50
Low Temperature Storage
Ta=-40℃
JEITA ED-4701
200 202
1000 hrs.
0/50
Steady State
Operating Life Condition 1
Ta=25℃, IF=20mA
1000 hrs.
0/50
Steady State
Operating Life Condition 2
Ta=25℃, IF=30mA
500 hrs.
0/50
Steady State
Operating Life of High
Temperature
Ta=85℃, IF=5mA
1000 hrs.
0/50
Steady State
Operating Life of High
Humidity Heat
60℃, RH=90% , IF=15mA
500 hrs.
0/50
Steady State
Operating Life of low
Temperature
Ta=-30℃, IF=20mA
1000 hrs.
0/50
Part
No. : LTW-006DCG-E2
BNS-OD-C131/A4
Page :
10
of
11
LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
7.2 Criteria for Judging the Damage
Criteria for Judgment
Min.
Max.
Item
Symbol
Test Conditions
Forward Voltage
VF
IF=20mA
-
U.S.L.*) ╳ 1.1
Luminous Intensity
IV
IF=20mA
U.S.L.**) ╳ 0.7
-
8. Others
The appearance and specifications of the product may be modified for improvement without prior notice.
9. Suggested Checking List
Training and Certification
1. Everyone working in a static-safe area is ESD-certified?
2. Training records kept and re-certification dates monitored?
Static-Safe Workstation & Work Areas
1. Static-safe workstation or work-E2reas have ESD signs?
2. All surfaces and objects at all static-safe workstation and within 1 ft measure less than 100V?
3. All ionizer activated, positioned towards the units?
4. Each work surface mats grounding is good?
Personnel Grounding
1. Every person (including visitors) handling ESD sensitive (ESDS) items wear wrist strap, heel strap or
conductive shoes with conductive flooring?
2. If conductive footwear used, conductive flooring also present where operator stand or walk?
3. Garments, hairs or anything closer than 1 ft to ESD items measure less than 100V*?
4. Every wrist strap or heel strap/conductive shoes checked daily and result recorded for all DLs?
5. All wrist strap or heel strap checkers calibration up to date?
Note: *50V for Blue LED.
Device Handling
1. Every ESDS items identified by EIA-471 labels on item or packaging?
2. All ESDS items completely inside properly closed static-shielding containers when not at static-safe
workstation?
3. No static charge generators (e.g. plastics) inside shielding containers with ESDS items?
4. All flexible conductive and dissipative package materials inspected before reuse or recycle?
Others
1. Audit result reported to entity ESD control coordinator?
2. Corrective action from previous audits completed?
3. Are audit records complete and on file?
Part No. : LTW-006DCG-E2
BNS-OD-C131/A4
Page :
11
of
11