LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only Features * Package in 12mm tape on 7" diameter reels. * Compatible with automatic placement equipment. * Compatible with infrared and vapor phase reflow solder process. * EIA STD package. * I.C. compatible. * Meet green product and Pb-free(According to RoHS) Package Dimensions Anode Part No. Lens Color Source Color LTW-006DCG-E2 Yellow InGaN White Notes: 1. All dimensions are in millimeters (inches). 2. Tolerance is ±0.1 mm (.004") unless otherwise noted. Part No. : LTW-006DCG-E2 BNS-OD-C131/A4 Page : 1 of 11 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only ℃ Absolute Maximum Ratings at Ta=25℃ Parameter LTW-006DCG-E2 Unit 120 mW (1/10 Duty Cycle, 0.1ms Pulse Width) 100 mA DC Forward Current 30 mA Reverse Voltage 5 V Power Dissipation Peak Forward Current Operating Temperature Range -30℃ to + 85℃ Storage Temperature Range -40℃ to + 100℃ Reflow Soldering Condition 260℃ For 10 Seconds Suggest IR Reflow Condition : R-Reflow Soldering Profile for lead free soldering (Acc. to J-STD-020B) Part No. : LTW-006DCG-E2 BNS-OD-C131/A4 Page : 2 of 11 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only Electrical Optical Characteristics Parameter Ta=25℃ ℃ Symbol Part No. LTW- Min. IV 006DCG-E2 1700 2θ1/2 006DCG-E2 Luminous Intensity Viewing Angle At Max. Unit Test Condition 2100 mcd IF = 20mA Note 1, 2, 5 deg Fig.6 110 x Chromaticity Coordinates Typ. IF = 20mA Note 3, 5 Fig.1 0.277 006DCG-E2 y 0.255 Forward Voltage VF 006DCG-E2 3.0 ESD-Withstand Voltage ESD 006DCG-E2 200V 3.5 V IF = 20mA V HBM Note : 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE eye-response curve. 2. Iv classification code is marked on each packing bag. 3. The chromaticity coordinates (x, y) is derived from the 1931 CIE chromaticity diagram. 4. Caution in ESD: Static Electricity and surge damages the LED. It is recommend to use a wrist band or anti-E2lectrostatic glove when handling the LED. All devices, equipment and machinery must be properly grounded. 5. CAS140B-1 is the test standard for the chromaticity coordinates (x, y) & IV. 6. The chromaticity coordinates (x, y) guarantee should be added +/- 0.007 tolerance. Part No. : LTW-006DCG-E2 BNS-OD-C131/A4 Page : 3 of 11 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only Bin Code List VF Spec. Table VF Bin Forward Voltage (V) at IF = 20mA Min. Max. V0 2.9 3.0 V1 3.0 3.1 V2 3.1 3.2 V3 3.2 3.3 V4 3.3 3.4 V5 3.4 3.5 V6 3.5 3.6 Tolerance on each Forward Voltage bin is +/-0.10 volt IV Spec. Table Luminous Intensity (mcd) at IF = 20mA IV Bin Min. Max. S81 1700 1750 S82 1750 1800 S91 1800 1850 S92 1850 1900 101 1900 1950 102 1950 2000 111 2000 2050 112 2050 2100 Tolerance on each Luminous Intensity bin is +/- 7%. Part No. : LTW-006DCG-E2 BNS-OD-C131/A4 Page : 4 of 11 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only Color Ranks Table Color bin limits at IF = 20mA Ranks C12 C21 C22 C31 C32 B12 B21 B22 B31 B32 CIE 1931Chromaticity coordinates x 0.265 0.27 0.27 0.265 y 0.237 0.245 0.258 0.25 x 0.27 0.275 0.275 0.27 y 0.245 0.253 0.266 0.258 x 0.275 0.28 0.28 0.275 y 0.253 0.261 0.274 0.266 x 0.28 0.285 0.285 0.28 y 0.261 0.269 0.282 0.274 x 0.285 0.29 0.29 0.285 y 0.269 0.277 0.29 0.282 x 0.265 0.27 0.27 0.265 y 0.224 0.232 0.245 0.237 x 0.27 0.275 0.275 0.27 y 0.232 0.24 0.253 0.245 x 0.275 0.28 0.28 0.275 y 0.24 0.248 0.261 0.253 x 0.28 0.285 0.285 0.28 y 0.248 0.256 0.269 0.261 x 0.285 0.29 0.29 0.285 y 0.256 0.264 0.277 0.269 Tolerance on each Hue (x, y) bin is +/- 0.007. * Color Coordinates Measurement allowance is ±0.007 Part No. : LTW-006DCG-E2 BNS-OD-C131/A4 Page : 5 of 11 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only Typical Electrical / Optical Characteristics Curves (25°° C Ambient Temperature Unless Otherwise Noted) Part No. : LTW-006DCG-E2 BNS-OD-C131/A4 Page : 6 of 11 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only User Guide Cleaning Do not use unspecified chemical liquid to clean LED they could harm the package. If cleaning is necessary, immerse the LED in ethyl alcohol or isopropyl alcohol at normal temperature for less one minute. Recommend Printed Circuit Board Attachment Pad Infrared / vapor phase Reflow Soldering Package Dimensions of Tape Note: 1.All dimensions are in millimeters (inches). Part No. : LTW-006DCG-E2 BNS-OD-C131/A4 Page : 7 of 11 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only Package Dimensions of Reel Notes: 1. Empty component pockets sealed with top cover tape. 2. 7 inch reel-2000 pieces per reel. 3. The maximum number of consecutive missing lamps is two. 4. In accordance with EIA-481-1-E2 specifications. Part No. : LTW-006DCG-E2 BNS-OD-C131/A4 Page : 8 of 11 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only CAUTIONS 1. Application The LEDs described here are intended to be used for ordinary electronic equipment (such as office equipment, communication equipment and household applications).Consult Liteon’s Sales in advance for information on applications in which exceptional reliability is required, particularly when the failure or malfunction of the LEDs may directly jeopardize life or health (such as in aviation, transportation, traffic control equipment, medical and life support systems and safety devices). 2. Storage This product is qualified as Moisture sensitive Level 3 per JEDEC J-STD-020 Precaution when handing this moisture sensitive product is important to ensure the reliability of the product. The package is sealed: The LEDs should be stored at 30°C or less and 90%RH or less. And the LEDs are limited to use within one year, while the LEDs is packed in moisture-proof package with the desiccants inside. The package is opened: The LEDs should be stored at 30°C or less and 60%RH or less. Moreover, the LEDs are limited to solder process within 168hrs. If the Humidity Indicator shows the pink color in 10% even higher or exceed the storage limiting time since opened, that we recommended to baking LEDs at 60°C at least 48hrs. To seal the remainder LEDs return to package, it’s recommended to be with workable desiccants in original package. 3. Cleaning Use alcohol-based cleaning solvents such as isopropyl alcohol to clean the LED if necessary. 4. Soldering Recommended soldering conditions: Reflow soldering Pre-heat Pre-heat time Peak temperature Soldering time 120~150°C 120 sec. Max. 260°C Max. 30 sec. Max. Soldering iron Temperature 300°C Max. Soldering time 3 sec. Max. (one time only) 5. Drive Method An LED is a current-operated device. In order to ensure intensity uniformity on multiple LEDs connected in parallel in an application, it is recommended that a current limiting resistor be incorporated in the drive circuit, in series with each LED as shown in Circuit A below. Circuit model A LED Circuit model B LED (A) Recommended circuit. (B) The brightness of each LED might appear different due to the differences in the I-V characteristics of those LEDs. Part No. : LTW-006DCG-E2 BNS-OD-C131/A4 Page : 9 of 11 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only 6. ESD (Electrostatic Discharge) Static Electricity or power surge will damage the LED. Suggestions to prevent ESD damage: Use of a conductive wrist band or anti-E2lectrostatic glove when handling these LEDs. All devices, equipment, and machinery must be properly grounded. Work tables, storage racks, etc. should be properly grounded. Use ion blower to neutralize the static charge which might have built up on surface of the LED’s plastic lens as a result of friction between LEDs during storage and handling. ESD-damaged LEDs will exhibit abnormal characteristics such as high reverse leakage current, low forward voltage, or “ no lightup ” at low currents. To verify for ESD damage, check for “ lightup ” and Vf of the suspect LEDs at low currents. The Vf of “ good ” LEDs should be >[email protected] for InGaN product 7.1 Reliability Test Test Item Test Condition Reference Standard Note Number of Damaged Resistance to Soldering Heat (Reflow Soldering) Tsld=260℃, 10sec. JEITA ED-4701 300 301 2 times 0/50 Solderability (Reflow Soldering) Tsld=245±5℃, 3sec. (Lead Free Solder) JEITA ED-4701 300 303 1 time Over 95% 0/50 Thermal Shock -30℃ ~ 85℃ 30min. 30min. JEITA ED-4701 300 307 100 cycles 0/50 Temperature Cycle -40℃ ~ 25℃ ~ 100℃ ~ 25℃ 30min. 5min. 30min. 5min. JEITA ED-4701 100 105 100 cycles 0/50 High Temperature Storage Ta=100℃ JEITA ED-4701 200 201 1000 hrs. 0/50 Temperature Humidity Storage Ta=60℃, RH=90% JEITA ED-4701 100 103 1000 hrs. 0/50 Low Temperature Storage Ta=-40℃ JEITA ED-4701 200 202 1000 hrs. 0/50 Steady State Operating Life Condition 1 Ta=25℃, IF=20mA 1000 hrs. 0/50 Steady State Operating Life Condition 2 Ta=25℃, IF=30mA 500 hrs. 0/50 Steady State Operating Life of High Temperature Ta=85℃, IF=5mA 1000 hrs. 0/50 Steady State Operating Life of High Humidity Heat 60℃, RH=90% , IF=15mA 500 hrs. 0/50 Steady State Operating Life of low Temperature Ta=-30℃, IF=20mA 1000 hrs. 0/50 Part No. : LTW-006DCG-E2 BNS-OD-C131/A4 Page : 10 of 11 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only 7.2 Criteria for Judging the Damage Criteria for Judgment Min. Max. Item Symbol Test Conditions Forward Voltage VF IF=20mA - U.S.L.*) ╳ 1.1 Luminous Intensity IV IF=20mA U.S.L.**) ╳ 0.7 - 8. Others The appearance and specifications of the product may be modified for improvement without prior notice. 9. Suggested Checking List Training and Certification 1. Everyone working in a static-safe area is ESD-certified? 2. Training records kept and re-certification dates monitored? Static-Safe Workstation & Work Areas 1. Static-safe workstation or work-E2reas have ESD signs? 2. All surfaces and objects at all static-safe workstation and within 1 ft measure less than 100V? 3. All ionizer activated, positioned towards the units? 4. Each work surface mats grounding is good? Personnel Grounding 1. Every person (including visitors) handling ESD sensitive (ESDS) items wear wrist strap, heel strap or conductive shoes with conductive flooring? 2. If conductive footwear used, conductive flooring also present where operator stand or walk? 3. Garments, hairs or anything closer than 1 ft to ESD items measure less than 100V*? 4. Every wrist strap or heel strap/conductive shoes checked daily and result recorded for all DLs? 5. All wrist strap or heel strap checkers calibration up to date? Note: *50V for Blue LED. Device Handling 1. Every ESDS items identified by EIA-471 labels on item or packaging? 2. All ESDS items completely inside properly closed static-shielding containers when not at static-safe workstation? 3. No static charge generators (e.g. plastics) inside shielding containers with ESDS items? 4. All flexible conductive and dissipative package materials inspected before reuse or recycle? Others 1. Audit result reported to entity ESD control coordinator? 2. Corrective action from previous audits completed? 3. Are audit records complete and on file? Part No. : LTW-006DCG-E2 BNS-OD-C131/A4 Page : 11 of 11