MEANWELL RS-50-48

RS-50
50W Single Output Switching Power Supply
series
Features :
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
SPECIFICATION
MODEL
OUTPUT
INPUT
RS-50-3.3
RS-50-5
RS-50-12
RS-50-15
RS-50-24
RS-50-48
DC VOLTAGE
3.3V
5V
12V
15V
24V
48V
RATED CURRENT
10A
10A
4.2A
3.4A
2.2A
1.1A
CURRENT RANGE
0 ~ 10A
0 ~ 10A
0 ~ 4.2A
0 ~ 3.4A
0 ~ 2.2A
0 ~ 1.1A
RATED POWER
33W
50W
50.4W
51W
52.8W
52.8W
RIPPLE & NOISE (max.) Note.2 80mVp-p
80mVp-p
120mVp-p
120mVp-p
120mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
4.75 ~ 5.5V
2.0%
10.8 ~ 13.2V
1.0%
13.5 ~ 16.5V
1.0%
22 ~ 27.2V
1.0%
42 ~ 54V
1.0%
3V ~ 3.6V
VOLTAGE TOLERANCE Note.3 3.0%
LINE REGULATION
Note.4
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
Note.5
2.0%
1.0%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
500ms, 20ms/230VAC
HOLD TIME (Typ.)
60ms/230VAC
VOLTAGE RANGE
88 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
72%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.3A/115VAC
0.8A/230VAC
COLD START 33A/230VAC
LEAKAGE CURRENT
1200ms, 30ms/115VAC at full load
14ms/115VAC at full load
125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
78%
81%
83%
84%
86%
<2mA / 240VAC
110 ~ 150% rated output power
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.45V
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
55.2 ~ 64.8V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-25 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY & ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
EMC
(Note 6)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A
228Khrs min. MIL-HDBK-217F (25
99*97*36mm (L*W*H)
0.41Kg; 45pcs/19.5Kg/0.9CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:RS-50-SPEC 2006-04-12
RS-50
50W Single Output Switching Power Supply
Mechanical Specification
Unit:mm
36
Case No. 905B
series
2
3.5
51.5
9.5
1
3
5.5
3
8.2
97
4
55.5
2-
M
5
20.5
55
3.5
4.5
89
99
6.5
3
3.5
74
18
36
2-M
28
3.5
17.5
7
87
Terminal Pin. No Assignment
Pin No.
1
2
3
Pin No.
4
5
Assignment
AC/L
AC/N
FG
Assignment
DC OUTPUT -V
DC OUTPUT +V
Output Derating
Output Derating VS Input Voltage
Ta=25
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-25
-25
0
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
70 (VERTICAL)
60
50
40
88
95
100
115
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:RS-50-SPEC 2006-04-12