RS-50 50W Single Output Switching Power Supply series Features : Universal AC input / Full range Protections:Short circuit/Over load/Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105 long life electrolytic capacitors Withstand 300VAC surge input for 5 second High operating temperature up to 70 Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty SPECIFICATION MODEL OUTPUT INPUT RS-50-3.3 RS-50-5 RS-50-12 RS-50-15 RS-50-24 RS-50-48 DC VOLTAGE 3.3V 5V 12V 15V 24V 48V RATED CURRENT 10A 10A 4.2A 3.4A 2.2A 1.1A CURRENT RANGE 0 ~ 10A 0 ~ 10A 0 ~ 4.2A 0 ~ 3.4A 0 ~ 2.2A 0 ~ 1.1A RATED POWER 33W 50W 50.4W 51W 52.8W 52.8W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 2.0% 10.8 ~ 13.2V 1.0% 13.5 ~ 16.5V 1.0% 22 ~ 27.2V 1.0% 42 ~ 54V 1.0% 3V ~ 3.6V VOLTAGE TOLERANCE Note.3 3.0% LINE REGULATION Note.4 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION Note.5 2.0% 1.0% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 500ms, 20ms/230VAC HOLD TIME (Typ.) 60ms/230VAC VOLTAGE RANGE 88 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 72% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.3A/115VAC 0.8A/230VAC COLD START 33A/230VAC LEAKAGE CURRENT 1200ms, 30ms/115VAC at full load 14ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 78% 81% 83% 84% 86% <2mA / 240VAC 110 ~ 150% rated output power OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 55.2 ~ 64.8V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC (Note 6) HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A 228Khrs min. MIL-HDBK-217F (25 99*97*36mm (L*W*H) 0.41Kg; 45pcs/19.5Kg/0.9CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:RS-50-SPEC 2006-04-12 RS-50 50W Single Output Switching Power Supply Mechanical Specification Unit:mm 36 Case No. 905B series 2 3.5 51.5 9.5 1 3 5.5 3 8.2 97 4 55.5 2- M 5 20.5 55 3.5 4.5 89 99 6.5 3 3.5 74 18 36 2-M 28 3.5 17.5 7 87 Terminal Pin. No Assignment Pin No. 1 2 3 Pin No. 4 5 Assignment AC/L AC/N FG Assignment DC OUTPUT -V DC OUTPUT +V Output Derating Output Derating VS Input Voltage Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -25 -25 0 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (VERTICAL) 60 50 40 88 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RS-50-SPEC 2006-04-12