MERRIMAC FBGI

FBGI-3.84G
FILTER
PRELIMINARY
REV: 003, 05/27/04
TECHNICAL DESCRIPTION / APPLICATION
MULTI-MIX® FILTERS
Merrimac’s FBGI Series bandpass filters combine the features of Merrimac’s
patented Multi-Mix® multilayer fabrication technology with the ability to operate to
three times their center frequency without reentrant spurious passbands. They typically offer better overall performance than filters designed to the same specification
with conventional filter fabrication techniques.
GENERAL SPECIFICATIONS
FILTER TYPE
CENTER
FREQUENCY
1 dB OPERATING
BANDWIDTH
(MHz MIN)
BANDPASS
3.84 GHz Nominal
400
SIZE
(INCHES)
WEIGHT
(GRAMS/OZ.)
RF
INTERFACE/CONNECTIONS
OPERATING
TEMPERATURE
0.5 x 0.5 x 0.05
0.6 / 0.02
SMT or 50 Ohm, co-planar waveguide
launch with gold pads
-55° - +85° C
INSERTION LOSS @
CENTER FREQUENCY
0.8 dB (MAX)
REJECTION
VSWR
(MAX)
-30 dB MIN. @ 2.0 GHz
-20 dB MIN. @ 5.4 GHz
-30 dB MIN. @ 7.2 GHz
1.5:1 @ 3.84±0.1 GHz
PACKAGE OUTLINE
NOTES:
1. ALL DIMENSIONS ARE IN INCHES.
2. TOLERANCES: -3 PLACE DECIMALS; ±.005.
THE MULTI-MIX MICROTECHNOLOGY® GROUP IS ISO 9001:2000 REGISTERED
U.S. patent 6,099,677 and other patents pending.
Merrimac Industries / 41 Fairfield Place, West Caldwell, NJ 07006
Tel: 1.888.434.MMFM / Fax: 973.882.5990 / Email: [email protected] / www.Multi-Mix.com
FBGI-3.84G
TYPICAL PERFORMANCE
Transmission vs. Frequency
0
-10
-20
Magnitude (dB)
-30
-40
-50
-60
-70
-80
2.00
2.50
3.00
3.50
4.00
4.50
5.00
5.50
6.00
6.50
7.00
Frequency (GHz)
Return Loss and Transmission vs. Frequency
0
-10
Magnitude (dB)
-20
Return Loss (dB)
Transmission (dB)
-30
-40
-50
-60
2
2.5
3
3.5
4
4.5
5
5.5
6
4.1
4.2
6.5
7
Frequency (GHz)
Near In Transmission vs. Frequency
0
Magnitude (dB)
-1
-2
-3
-4
-5
3.3
3.4
3.5
3.6
3.7
3.8
3.9
4
4.3
4.4
4.5
Frequency (GHz)
THE MULTI-MIX MICROTECHNOLOGY® GROUP IS ISO 9001:2000 REGISTERED