MIC FR806

FAST RECOVERY RECTIFIER
FR801 THRU FR806
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
8.0 Ampere
FEATURES
•
•
•
•
•
•
•
•
TO-220AC
Glass passivated chip junction
Low cost construction
Fast switching for high efficiency
Low reverse leakage
High forward surge current capacity
High temperature soldering guaranteed
260℃/10 second,0.375″(9.5mm)lead length
at 5 lbs (2.3kg) tension
MECHANICAL DATA
•
•
•
•
•
•
Case: Transfer molded plastic
Epoxy: UL94V-0 rate flame retardant
Polarity: Color band denotes cathode end
Lead: Plated axial lead, solderable per MIL-STD-202E method 208C
Mounting position: Any
Weight: 0.064ounce, 1.81 gram
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
•
•
•
Ratings at 25℃ ambient temperature unless otherwise specified
Single Phase, half wave, 60Hz, resistive or inductive load
For capacitive load derate current by 20%
SYMBOLS FR801
FR802
Maximum Repetitive Peak Reverse Voltage
VRRM
50
100
Maximum RMS Voltage
VRMS
35
70
Maximum DC Blocking Voltage
VDC
50
100
Maximum Average Forward Rectified Current
0.375″(9.5mm) lead length at Tc=100℃
Peak Forward Surge Current
8.3ms single half sine wave superimposed on
rated load (JEDEC method)
FR803
200
140
200
FR804
400
280
400
FR805
600
420
600
FR806
800
560
800
UNIT
Volts
Volts
Volts
I(AV)
8.0
Amps
IFSM
200
Amps
Maximum Instantaneous Forward Voltage at 8.0A
VF
IR
1.3
10
500
Volts
Maximum DC Reverse Current at rated TA = 25℃
DC Blocking Voltage per element
TA = 100℃
Maximum Reverse Recovery Time (NOTE 3)Tj=25℃
Typical Junction Capacitance (NOTE 1)
Typical Thermal Resistance (NOTE 2)
Operating and Storage Temperature Range
Storage Temperature Range
trr
CJ
RθJC
TJ
TSTG
150
250
50
3.0
(-55 to +150)
(-55 to +150)
Notes:
1. Measured at 1.0 MHz and applied reverse voltage of 4.0 Volts.
2. Thermal Resistance from Junction to CASE
3. Reverse Recovery Test Conditions: IF =0.5A, IR =1.0A, IRR =0.25A
E-mail: [email protected]
Web Site: www.cnmic.com
µA
500
nS
pF
℃/W
℃
℃
FAST RECOVERY RECTIFIER
FR801 THRU FR806
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
8.0 Ampere
RATING AND CHRACTERISTIC CURVES FR801G THRU FR806
FIG.1-TYPICAL FORWARD CURRENT
FIG.2-MAXIMUM NON-REPETITIVE PEAK
DERATING CURVE
FORWARD SURGE CURRENT
Single Phase
Half Wave 60Hz
Resistive or
Inductive Load
0.375″(9.5mm)
Lead Length
(A)
8.0
4.0
300
CURRENT, (A)
PEAK FORWARD SURGE
AVERAGE FORWARD CURRENT,
12.0
8.3ms Single Half Sine-Wave
(JEDEC Method) T= T jmax
200
100
1 Cycle
0
0
25
50
100
75
125
175
150
0
1
2
AMBIENT TEMPERATURE, (° C)
4
FIG.3-TYPICAL INSTANTANEOUS
0.1
TJ =25° C
Pulse Width=300us
1% Duty Cycle
0.8
1.0
1.2
1.4
1.6
40
20
60 80 100
10
TJ =100° C
1
(μA)
INSTANTANEOUS REVERSE CURRENT,
1.0
(A)
INSTANTANEOUS FORWARD CURRENT,
20
10
0.6
8 10
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
FORWARD CHARACTERISTICS
0.01
0.4
6
NUMBER OF CYCLES AT 60 Hz
TJ =25° C
0.1
0.01
1.8
0
20
INSTANTANEOUS FORWARD VOLTAGE,(V)
40
60
100
80
120
140
PERCENT OF RATED PEAK
REVERSE VOLTAGE,(%)
FIG.5-TYPICAL JUNCTION CAPACITANCE
JUNCTION CAPACITANCE,(pF)
1000
F1G.6-TEST CIRCUIT DIAGRAM AND
REVERSE RECOVERY TIME CHARACTERISTIC
Trr
50Ω
10Ω
NONINDUCTIVE NONINDUCTIVE
+0.5A
(-)
100
(+)
25 Vdc
(approx.)
(-)
T J =25° C
f=1MHz
Vsig=50mVp-p
1.0
1Ω
NON
INDUCTIVE
PULSE
GENERATIOR
(NOTE 2)
0
-0.25A
(+)
OSCILLOSCOPE
(NOTE 1)
-1.0A
10
0.1
D.U.T.
10
100
REVERSE VOLTAGE,(V)
E-mail: [email protected]
NOTES : 1.Rise Time=7ns mas. Input Impedance=
1 magohm. 22pF
2.Rise time=10ns max. Source Impedance=
50 ohms
Web Site: www.cnmic.com
1cm
SET TIME BASE FOR
50/100ns/cm