A tognum Group Brand Diesel Engine-Generator Set 50-JS6DT3 50 ekW / 60 Hz / Standby 208 - 600V System Ratings Standby Voltage (L-L) Phase PF Hz kW kVA AMPS skVA@30% Voltage Dip Generator Model Temp Rise Connection 240V** 1 1.0 60 50 50 208 208V** 3 0.8 60 50 62.5 173 240V** 3 0.8 60 50 62.5 150 480V** 3 0.8 60 50 62.5 75 600V** 3 0.8 60 50 62.5 60 91 361CSL1602 130°C/27°C 12 LEAD ZIG-ZAG 105 361CSL1602 130°C/27°C 12 LEAD LOW WYE 105 361CSL1602 130°C/27°C 12 LEAD HI DELTA 140 361CSL1602 130°C/27°C 12 LEAD HI WYE 138 361CSL1633 125°C/40°C 4 LEAD WYE ** UL2200 Offered Facts // // // // // // // // // EPA Tier 3 Certified Engine-Generator Set Tested to ISO 8528-5 for Transient Response UL2200, CSA Listing Offered Accepts Rated Load in One Step Per NFPA 110, Level 1 All engine-generator sets are prototype and factory tested MTU Onsite Energy is a single source supplier Global Product Support 2 Year Standard Warranty 4024HF285 Diesel Engine - 2.4 Liter Displacement - Electronic Unit Pump Injection - 4-Cycle // // // // Complete Range of Accessories Permanent Magnet Generator (PMG) - Optional - Brushless, Rotating Field - 300% Short Circuit Capability - 2/3 Pitch Windings Digital Control Panel(s) - UL Recognized, , NFPA 110 - Complete System Metering - LCD Display Cooling System - Integral Set-Mounted - Engine Driven Fan 2 / // / 50-JS6DT3 STANDARD EQUIPMENT // Engine Air Cleaner Oil Pump Full Flow Oil Filter Jacket Water Pump Closed Crankcase Vent Thermostat Exhaust Manifold – Dry Blower Fan & Fan Drive Radiator - Unit Mounted Electric Starting Motor - 12V Governor – Electric Isochronous Base - Formed Steel SAE Flywheel & Bell Housing Charging Alternator - 12V Battery Box & Cables Flexible Fuel Connectors Flexible Exhaust Connection EPA Certified Engine // Generator NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor starting Sustained short circuit current of up to 300% of the rated current for up to 10 seconds Self-Ventilated and Drip-Proof Superior Voltage Waveform Digital, Solid State, Volts-per-Hertz Regulator No Load to Full Load Regulation Brushless Alternator with Brushless Pilot Exciter 4 Pole, Rotating Field 130°C Standby Temperature Rise 1 Bearing, Sealed Flexible Coupling Full Amortisseur Windings 125% Rotor Balancing 3-Phase Voltage Sensing ±1% Voltage Regulation 100% of Rated Load - One Step 3% Maximum Harmonic Content // Digital Control Panel(s) Digital Metering Engine Parameters Generator Protection Functions Engine Protection SAE J1939 Engine ECU Communications Windows-Based Software Multilingual Capability Remote Communications to our RDP-110 Remote Annunciator 16 Programmable Contact Inputs 7 Contact Outputs UL Recognized, , CE Approved Event Recording IP 54 Front Panel Rating with Integrated Gasket NFPA110 Level Compatible // Additional Features Oil Drain Extension & S/O Valve Flexible Fuel Connector Battery Cables Vibration Isolation Pads Jacket Water Heater: -20° F Mainline Circuit Breaker UL2200 Listed Steel Sub-Base Radiator Duct Flange (OPU) Lube Oil & Antifreeze Operator’s and Owner’s Manual 2 Year/3000 Hour Warranty Factory Tested at 0.8 PF (3 PH) // Optional Features Battery Charger: 6 Amp or 10 Amp Battery: 12 Volt w/ Rack Circuit Breaker: Standard or 100% Muffler (OPU only) Sub-Base Fuel Tank w/ Electrical Stub-Up Area Weatherproof Enclosure Sound Attenuation - 1 1/2” Foam - Sound Scoops Remote Annunciator Isochronous Governor 3 / // / 50-JS6DT3 Application data // Engine Manufacturer Model Type Arrangement Displacement: Cu In (lit) Bore: in (cm) Stroke: in (cm) Compression Ratio Rated RPM Engine Governor Max Power: Standby: bhp (kWm) Speed Regulation Frequency Air Cleaner // John Deere 4024HF285 4-Cycle 4-Inline 146 (2.4) 3.4 (8.6) 4.1 (10.5) 18.2:1 1,800 JDEC 80 (60) ±.25% 60 Hz Dry Liquid Capacity (Lubrication) Total Oil System: gal (lit) Engine Jacket Water Capacity: gal (lit) System Coolant Capacity: gal (lit) // // Electrical Electric Volts DC Cold Cranking Amps Under 0°F (-17.8°C) At 100% of Power Rating: gal/hr (lit/hr) At 75% of Power Rating: gal/hr( lit/hr) At 50% of Power Rating: gal/hr (lit/hr) // 12 750 Fuel System Fuel Supply Connection Size Fuel Return Connection Size Maximum Fuel Lift: ft (m) Recommended Fuel Total Fuel Flow: gal/hr (lit/hr) 3/8” NPT 3/8” NPT 10 (3) Diesel #2 21.7 (82) 122 (50) 0.5 (0.12) 26 (100) 1,988 (34.9) 608 (10.7) 503 (9) Air Requirements Aspirating: *SCFM (m3/min) Air Flow Required for Rad. Cooled Unit: *SCFM (m3/min) Air Flow Required for Heat Exchanger/Remote Rad. based on 25°F Rise: *SCFM (m3/min) 151 (4.3) 4,511 (128) 1,134 (32) * Air density = 0.0739 lbm/ft3 (1.184 kg/m3) // // 4.3 (16.3) 3.2 (12.1) 2.2 (8.3) Cooling - Radiator System Ambient Capacity of Radiator: °F (°C) Max. Restriction of Cooling Air, Intake, and Discharge Side of Rad.: in. H20 (kPa) Water Pump Capacity: gpm (lit/min) Heat Rejection to Coolant: BTUM (kW) Heat Rejection to Air to Air: BTUM (kW) Heat Radiated to Ambient: BTUM (kW) // 2.1 (7.9) 0.68 (2.6) 3 (11.4) Fuel Consumption Exhaust System Gas Temp. (Stack): °F (°C) Gas Volume at Stack Temp: CFM (m3/min) Maximum Allowable Back Pressure: in. H20 (kPa) Minimum Allowable Back Pressure: in. H20 (kPa) 1,062 (572) 419 (11.9) 30 (7.5) 16 (4) 4 / // / 50-JS6DT3 Weights and dimensions Drawing above for illustration purposes only, based on standard open power 480 volt generator. Lengths may vary with other voltages. Do not use for installation design. SystemDimensions (L x W x H) OPU 85 x 38 x 51 in (2,160 x 970 x 1,300 mm) EPU 85 x 38 x 60 in (2,160 x 970 x 1,520 mm) Weight (less tank) 1,598 lb (725 kg) 1,918 lb (870 kg) Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set. Sound data Standby Full Load 85.3 77.3 Standby No Load 80 72 Measurements for sound data are taken at 23 ft (7m). Emissions data NOx + NMHC 3.5 COPM 0.86 0.12 All units are in g/hp-hr and are EPA D2 cycle values. Emission levels of the engine may vary as a function of ambient temperature, barometric pressure, humidity, fuel type and quality, installation parameters, measuring instrumentation, etc. The data provided are laboratory results from one engine representing this rating. The data was obtained under controlled environmental conditions with calibrated instrumentation traceable to the United States National Bureau of Standards and in compliance with US EPA regulations found within 40 CFR Part 89. The weighted cycle value from each engine is guaranteed to be below the US EPA Standards at the US EPA defined conditions. Rating Definitions and conditions Ambient capability factor at 984 ft (300 m). Consult your local MTU Onsite Energy Power Generation Distributor for other altitudes. // Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. No overload capability for this rating. Ratings are in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. // Deration Factor: Altitude: 0.5% per 1,000 ft (305 m) above sea level and 4% per 1,000 ft (305 m) above 10,000 ft (3,050 m). Temperature: 0.5% per 10°F (5.5°C) above 77°F (25°C). // Materials and specifications subject to change without notice. // Tognum Group Companies: Europe / Middle East / Africa / Latin America / MTU Onsite Energy / 88040 Friedrichshafen / Germany / Phone + 49 7541 90 7060 / Fax +49 7541 90 7084 / [email protected] // Asia / Australia / Pacific / MTU Onsite Energy / 1, Benoi Place / Singapore 629923 / Republic of Singapore / Phone + 65 6861 5922 / Fax + 65 6861 3615 / [email protected] // USA / Canada / Mexico / MTU Onsite Energy / 100 Power Drive / Mankato, Minnesota 56001 / USA / Phone + 1 507 625 7973 / Fax + 1 507 625 2968 / [email protected] // Worldwide for HotModule / MTU Onsite Energy / 81663 Munich / Germany / Phone + 49 89 203042 800 / Fax +49 89 203042 900 / [email protected] // www.mtu-online.com © MTU Onsite Energy. Subject to alteration due to technological advances. 2009-05 Unit Type OPU w/ Critical Grade Muffler (dBA) Sound Attenuated Enclosure (dBA)