NEWHAVEN NHD-C12864HZ-FN-FBW

 NHD‐C12864HZ‐FN‐FBW COG (Chip‐On‐Glass) Liquid Crystal Display Module NHD‐ C12864‐ HZ‐ F‐ N‐ F‐ B‐ W‐ Newhaven Display 128 x 64 pixels Model Transflective No backlight FSTN (+) 6:00 view Wide Temp (‐20°C ~ +70°C) RoHS Compliant Newhaven Display International, Inc. 2511 Technology Drive, Suite 101 Elgin IL, 60124 Ph: 847‐844‐8795 Fax: 847‐844‐8796 www.newhavendisplay.com [email protected] [email protected] [1] Document Revision History Revision 0 1 2 3 4 Date 1/29/2008 9/29/2009 10/13/2009 12/4/2009 3/10/2010 Description Initial Release User guide reformat Updated Electrical Characteristic Corrected Storage Temperature Corrected Pin 28 to “Active LOW chip select” Functions and Features •
•
•
•
•
•
128 x 64 Pixels Built‐in TL0324S controller 3.0V Power Supply 1/65 duty cycle; 1/9 bias Parallel Interface RoHS Compliant [2] Changed by ‐ BE MC MC MC 2/12/2007
NHD-C12864HZ-FN-FBW
8
9/24/09
Newhaven Display
Pin Description and Wiring Diagram Pin No. Symbol 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16‐23 24 25 26 27 28 A K VDD C86 VSS V0 V4 V3 V2 V1 C2‐ C2+ C1+ C1‐ C3+ Vout VSS DB7‐DB0 E RW RS /RESET /CS External Connection Power Supply MPU Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply MPU MPU MPU MPU MPU MPU Power Supply Power Supply Function Description
Power supply for logic (+3.0V)
Select MPU interface pin. C86=H: 6800; C86=L: 8080 Ground
1.0uF‐2.2uF cap to VSS
1.0uF‐2.2uF cap to VSS
1.0uF‐2.2uF cap to VSS
1.0uF‐2.2uF cap to VSS
1.0uF‐2.2uF cap to VSS
Connect to 1uF cap to CAP2+ (PIN 10 ) Connect to 1uF cap to CAP2‐ (PIN 9 ) Connect to 1uF cap to CAP1‐(PIN 12) Connect to 1uF cap to CAP1+(PIN 11) and CAP3+(PIN 13) Connect to 1uF cap to CAP1‐ (PIN 12)
Connect to 1uF cap to Vss
Ground
8 bi‐directional three‐state data bus lines.
Operation enable signal. Falling edge triggered. Read/write select signal. R/W=1: Read R/W=0: Write Register select signal. RS=0: Command, RS=1: Data Active LOW Reset signal Active LOW chip select Power supply for LED Backlight (+3.0V)
Ground for Backlight
Recommended LCD connector: 0.8mm pitch pins. Backlight connector: ‐‐ Mates with: ‐‐ [4] Electrical Characteristics Item Operating Temperature Range Storage Temperature Range Supply Voltage Supply Current Supply for LCD (contrast) “H” Level input “L” Level input “H” Level output “L” Level output Symbol TOP TST VDD IDD VDD‐V0 Vih Vil Voh Vol Condition
Absolute Max
Absolute Max
Ta=25⁰C VDD=3.0V
Ta=25⁰C
Min.
‐20
‐30
2.9
‐
‐
0.2VDD
Vss
0.2VDD
Vss
Typ.
‐
‐
3.0
0.42
8.8
‐
‐
‐
‐
Max. +70 +80 ‐ 0.62 9.1 VDD 0.2VDD VDD 0.2VDD Unit
⁰C
⁰C
V
mA
V
V
V
V
V
Optical Characteristics Item Viewing Angle ‐ Vertical Viewing Angle ‐ Horizontal Contrast Ratio Response Time (rise) Response Time (fall) Symbol θ Φ CR Tr Tf Condition
CR ≥2
CR ≥2
Min.
‐60
‐40
‐
‐
‐
Typ.
‐
‐
6
150
150
Max. +35 +40 ‐ 250 250 Unit
⁰ ⁰ ‐ ms
ms
Controller Information Built‐in TL0324S. Download specification at http://www.newhavendisplay.com/app_notes/TL0324S.pdf [5] Write Timing: Read Timing:
[6] Table of Commands [7] Quality Information Test Item Content of Test High Temperature storage Endurance test applying the high storage temperature for a long time. Endurance test applying the low storage temperature for a long time. Endurance test applying the electric stress (voltage & current) and the high thermal stress for a long time. Endurance test applying the electric stress (voltage & current) and the low thermal stress for a long time. Endurance test applying the electric stress (voltage & current) and the high thermal with high humidity stress for a long time. Endurance test applying the electric stress (voltage & current) during a cycle of low and high thermal stress. Endurance test applying vibration to simulate transportation and use. Low Temperature storage High Temperature Operation Low Temperature Operation High Temperature / Humidity Operation Thermal Shock resistance Vibration test Static electricity test Test Condition Endurance test applying electric static discharge. 2 ‐10⁰C , 48hrs
1,2
+70⁰C 48hrs
2 ‐20⁰C , 48hrs
1,2
+40⁰C , 90% RH , 48hrs 1,2
‐0⁰C,30min ‐> 25⁰C,5min ‐> 50⁰C,30min = 1 cycle 10 cycles 10‐55Hz , 15mm amplitude. 60 sec in each of 3 directions X,Y,Z For 15 minutes VS=800V, RS=1.5kΩ, CS=100pF One time Note 1: No condensation to be observed. Note 2: Conducted after 4 hours of storage at 25⁰C, 0%RH. Note 3: Test performed on product itself, not inside a container. Precautions for using LCDs/LCMs See Precautions at www.newhavendisplay.com/specs/precautions.pdf Warranty Information and Terms & Conditions http://www.newhavendisplay.com/index.php?main_page=terms [8] Note
+60⁰C , 48hrs
3