NI TBX-1316

SCXI High-Voltage Attenuator Terminal Block
NI TBX-1316
• Cabled terminal block for:
• SCXI-1125 (recommended)
• SCXI-1120/D
• SCXI-1126
• Input voltage range
• 1,000 V Cat I
• 600 V Cat II
• 200:1 attenuation (fixed)
• 8 differential input channels
• Lockable shielded metal enclosure
• Screw-terminal signal connectivity
• Secure strain-relief wire collars
• Flanges for panel mounting
Operating Systems
• Windows 2000/NT/XP
Recommended Software
• LabVIEW
• LabWindows/CVI
• Measurement Studio
Other Compatible Software
• Visual Basic, C, C++
Measurement Services
Software
• NI-DAQmx Driver Software
Overview
Measurement Services Software
The National Instruments TBX-1316 is a high-voltage attenuator
terminal block for the SCXI-1125, SCXI-1120/D, and SCXI-1126
analog input modules. The NI TBX-1316 extends the input voltage
range for AC/DC signals to 1,000 V for Category I installations and
600 V for Category II installations. For voltage measurements, the
TBX-1316 is recommended for use with the SCXI-1125, but can also
be used with the SCXI-1120/D. For frequency measurements, you
can use the TBX-1316 with the SCXI-1126.
NI-DAQmx is the robust driver software included with all
National Instruments data acquisition and signal conditioning
products. This easy-to-use software tightly integrates the full
functionality of your DAQ hardware to NI LabVIEW,
LabWindows/CVI, and Measurement Studio for Visual Basic.
High-performance features include multidevice synchronization,
networked measurements, and DMA data management. Bundled
with NI-DAQmx, Measurement & Automation Explorer (MAX)
simplifies measurement hardware configuration with device test panels,
interactive measurements, and scaled I/O channels. NI-DAQmx also
provides numerous example programs for LabVIEW and other
application development environments to get you started with your
application quickly.
Features
The TBX-1316 provides 200:1 attenuation for eight differential input
channels. Screw terminals provide connectivity for primary, neutral,
and ground connections. Additionally, wire strain-relief collars secure
cables in place. A rigid metal enclosure ensures safety and proper
grounding and also assists in easy panel-mount installation. The
TBX-1316 contains calibration EEPROMs, which when used with the
SCXI-1125, provide calibration information specific to each input
channel. The SH3232 shielded cable should be used to connect the
TBX-1316 to the analog input module.
Ordering Information
NI TBX-1316 ................................................................777207-16
BUY NOW!
For complete product specifications, pricing, and accessory
information, call (800) 813 3693 (U.S. only)
or go to ni.com/signalconditioning.
SCXI High-Voltage Attenuator Terminal Block
Specifications
Input Voltage Range
Input Voltage Range
AC/DC ............................................................
AC/DC ............................................................
Max input current per channel ........................
Impulse overvoltage ........................................
Bandwidth (3 dB)
SCXI-1125 ..................................................
SCXI-1120 ..................................................
Attenuation ratio .......................................
Attenuation-ratio accuracy
Uncalibrated .............................................
Attenuation-ratio temperature drift ..........
Differential input resistance .....................
Safety
1,000 V Category I
600 V Category II
50 µA
4000 V
400 Hz
400 Hz
200:1 (fixed)
1% max
20 ppm/°C max
44 MΩ typ
Physical
NI recommends that the TBX-1316 be permanently connected equipment with an appropriate UL Listed
external breaker for each line. Enclosure protective earth (PE) ground must be installed.
Dimensions....................................................... 30.48 by 25.40 by 15.24 cm (12 by 10 by 6 in.)
Weight ............................................................ 5.8 kg (12.8 lb)
Strain-relief cable diameter............................. 6 to 12 mm signals (0.24 to 0.47 in.)
4 to 8 mm PE ground (0.157 to 0.314 in.)
Note: If your application cable diameter is smaller than what is listed above, replace the supplied strain reliefs
with the following strain reliefs or their equivalents. These strain reliefs are not supplied with the TBX-1316.
Strain-relief cable diameter............................. 5 to 9 mm signals (0.197 to 0.354 in.)
SKINTOP # S2213
2 to 6 mm PE ground (0.079 to 0.236 in.)
SKINTOP # S2209
Strain reliefs available..................................... 8 signals
1 PE ground
Field wire
Diameter .................................................... 6 to 20 AWG
Temperature rating .................................... 90 °C
Connector type ................................................. Screw terminal
The TBX-1316 is designed to meet the requirements of the following standards of safety for electrical
equipment for measurement, control, and laboratory use:
• IEC 61010-1, EN 61010-1
• UL 61010-1
• CAN/CSA-C22.2 No. 61010-1
Note: For UL and other safety certifications, refer to the product label, or visit ni.com/certification, search
by model number or product line, and click the appropriate link in the Certification column.
Electromagnetic Compatibility
Emissions.......................................................... EN 55011 Class A at 10 m
FCC Part 15A above 1 GHz
Immunity .......................................................... EN 61326:1997 + A2:2001,
Table 1
EMC/EMI ......................................................... CE, C-Tick, and FCC Part 15
(Class A) Compliant
Note: For EMC compliance, operate this device with shielded cabling.
CE Compliance
The TBX-1316 meets the essential requirements of applicable European Directives, as amended for CE
marking, as follows:
Low-Voltage Directive (safety)......................... 73/23/EEC
Electromagnetic Compatibility
Directive (EMC) ......................................... 89/336/EEC
Note: Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory
compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model
number or product line, and click the appropriate link in the Certification column.
Environmental
Operating temperature.....................................
Storage temperature .......................................
Relative Humidity ............................................
Maximum altitude ...........................................
Pollution degree (indoor use only) ...................
0 to 55 °C
–20 to 70 °C
10 to 90%, noncondensing
2,000 m
2
National Instruments • Tel: (800) 813 3693 • [email protected] • ni.com
2
NI Services and Support
NI has the services and support to meet your
needs around the globe and through the
application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Local Sales and Technical Support
SERVICE
NEEDS
In offices worldwide, our staff is local to the country, giving you
access to engineers who speak your language. NI delivers industryleading technical support through online knowledge bases, our
applications engineers, and access to 14,000 measurement and
automation professionals within NI Developer Exchange forums.
Find immediate answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of
technical support. Visit ni.com/ssp.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save
development time, and reduce maintenance costs over the
application life cycle. We schedule instructor-led courses in cities
worldwide, or we can hold a course at your facility. We also offer a
professional certification program that identifies individuals who
have high levels of skill and knowledge on using NI products.
Visit ni.com/training.
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and
configure the system to your specifications. NI extends the standard
warranty by one year on hardware components (controllers, chassis,
modules) purchased with FIS. To use FIS, simply configure your
system online with ni.com/pxiadvisor.
Professional Services
Our Professional Services Team is comprised of NI applications
engineers, NI Consulting Services, and a worldwide National Instruments
Alliance Partner program of more than 600 independent consultants
and integrators. Services range
from start-up assistance to
turnkey system integration.
Visit ni.com/alliance.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
We offer design-in consulting and product integration assistance
if you want to use our products for OEM applications. For
information about special pricing and services for OEM customers,
visit ni.com/oem.
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
ni.com • (800) 813 3693
National Instruments • [email protected]
© 2005 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Mesurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com,
NI-DAQ, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies.
A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.
2005_5418_321_101_D
OEM Support