POWER-SYSTEMS CXA-0323

DC-AC INVERTER UNIT
CXA-0323 SERIES (3.0W SINGLE OUTPUT)
(PRELIMNARY, Custom Design)
DESCRIPTION :
This DC-to-AC inverter is developed for Sharp Display LQ038Q5DR01. The output current of the
inverter is reduced to prolong CCFL life time. The inverter is equipped with a dimming input which
permits CCFL brightness control by applying an external PWM signal.
APPLICATION:
FEATURES :
Single lamp type
Lamp Voltage 530V
Lamp Current typ. 4 mA
High Efficiency (typ. 85%)
Fuse protection
Ext. PWM Dimming with internal Pull-Up 1,5 kohm
Low noise with voltage resonant circuit
CXA-0323
1
4 mm diameter 2.2±0.2
16±0.2
3
1 max
2
8 max
1
CN2
1
(2)
80.5 max
60±0.2
(8)
CN1
20.5max
14±0.2
(3)
TEMPERATURE
& HUMDITY :
Operating Temperature Range
0 °C ~ +60°C
Storage Temperature Range
-40 °C ~ +85°C
Humidity
95 %RH max
MAX. RATING: Input Voltage: min. 9,6 Vdc; max. 14,4 VDC (the output current is different)
Output Power: max. 3,5 Watt
DIMENSIONS :
No. Part Description Qty.
1
1
PWB
Connector
CN1
1
2
Connector
CN2
1
3
Note
UL94V-0
53261-0590
Symbol
Vin
GND
Ext. PWM
N.C.
N.C.
t=1mm
(Molex)
SM02(8.0)B-BHS
CN1 : 53261-0590 (Molex)
Pin
CN1-1
CN1-2
CN1-3
CN1-4
CN1-5
Item
(JST)
CN2 : SM02(8.0)B-BHS (JST)
Note
+ 12 Vdc
0 Vdc
Typ. 120 Hz
Pin
CN2-1
CN2-2
CN2-3
Symbol
Iout
N.C.
Iout-ret
Note
Typ. 4 mArms
(2V)
Power Systems – The Power Solution
Web:
http://www.Power-Systems.de
Email Europe:
[email protected]
Email UK: [email protected]
All specification are subject to change without notice.
Adress: Dörnet 8; 74360 Ilsfeld-Auenstein / Germany
Tel. Europe: ++ 49 / 7062 / 6759 - 6
Tel. UK: ++ 44 / 1234 / 215811
Fax: ++ 49 / 7062 / 6759 - 80
Page ( 1 / 2 )
VER, 22/08/2001
DC-AC INVERTER UNIT
CXA-0323 SERIES (3.0W SINGLE OUTPUT)
(PRELIMNARY, Custom Design)
ELECTRICAL CHARACTERISTICS :
Parameter
Symbol
Conditions
Specification
Vin (V)
Ta (°C)
RL (kohm)
Min.
Typ.
Max.
Unit
Note
Output Current
Iout
12 +/-1%
23 +/-5
120
3,5
4,0
4,5
mArms
Input Current
Iin
12 +/-5%
0 ~ +60
110 ~ 130
-
0,3
0,5
Adc
Frequency
FL
12 +/-5%
0 ~ +60
110 ~ 130
33
40
47
kHz
Open Voltage
Vopen
12 +/-5%
0 ~ +60
110 ~ 130
1.300
1.500
-
Vrms
PWM Frequency
F
12 +/-5%
0 ~ +60
110 ~ 130
100
120
200
Hz
PWM Duty Circle
%
12 +/-5%
0 ~ +60
110 ~ 130
0
-
100
%
1
PWM Off Voltage
Voff
12 +/-5%
0 ~ +60
110 ~ 130
0,5
-
-
Vdc
2
Note 1: PWM Duty Cycle 0% without device degradation
Note 2: External switch to ground. The Inverter has an internal Pull-Up-Resistor inside.
+ 12 VDC
1,5 kohm
HV out
PWM in
GND
APPLICATION (for example)
Ext. PWM Type
HV low
CN1-1(Vin)
CN2-1(Iout)
CN1-2(GND)
CN1-3 (ext. PWM)
CN1-4(NC)
CN1-5(NC)
CXA-0323
SM02(8.0)B-BHS
(JST)
Vin
CCFL
RL
CN2-3(Iout-ret)
Power Systems – The Power Solution
Web:
http://www.Power-Systems.de
Email Europe:
[email protected]
Email UK: [email protected]
All specification are subject to change without notice.
Adress: Dörnet 8; 74360 Ilsfeld-Auenstein / Germany
Tel. Europe: ++ 49 / 7062 / 6759 - 6
Tel. UK: ++ 44 / 1234 / 215811
Fax: ++ 49 / 7062 / 6759 - 80
Page ( 2 / 2 )
VER, 22/08/2001