POWER-SYSTEMS PUS-2412-2W

DC-DC Converter UNIT
PU-2W Series ( 2 W UNREGULATED DC-DC CONVERTER)
FEATURES
1000VDC ISOLATION
EFFICIENCY UP TO 85%
INTERNAL SMD TECHNOLOGY
LOW COST
NO HEATSINK REQUIRED
UP TO 2W UNREGULATED
OUTPUT POWER
SINGLE IN LINE PACKAGE
100% BURNED IN
MTBF > 1,800,000 HOURS
z
z
z
z
z
z
z
z
z
z
z
OUTPUT SPECIFICATIONS
Voltage Setpoint Accuracy
+/-2% max
Temperature Coefficient
+/-0.03%/ OC
Ripple & Noise (20MHz
INPUT SPECIFICATIONS
Input Voltage Range
Input Filter
+/-10% max
Capacitor Type
100mVp-p max
BW)
Line Regulation1
Load Regulation
+/-1.2% max
2
+/-8% max
Short Circuit Protection
Momentary
z
GENERAL SPECIFICATIONS
Efficiency
70%-85%
3
z
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Cooling
Isolation Voltage
1000 VDC min
Isolation Resistance
9
10 ohms min
-25 OC to +71 OC
Switching Frequency
100 KHz min
-55 OC to +125 OC
Isolation Capacitance
80pF max
Free-Air Convection
MTBF
Weight
1,800,000 Hours
2.3g Typ
ALL SPECIFICATIONS TYPICAL AT NOMINAL
Case Material
Non-Conductive Plastic
LINE,
Case Size
19.6mm*7.1mm*10.2mm
FULL
LOAD
,
AND
25
O
C
UNLESS
OTHERWISE NOTED.
1
Line Regulation is for a 1.0% change in input Voltage.
2
Load Regulation is for output load current change from 20% to 100%.
3
For 60 seconds
www.Power-Systems.de
Page: 1 / 6
Version: 4-Oct-02
DC-DC Converter UNIT
PU-2W Series ( 2 W UNREGULATED DC-DC CONVERTER)
z SELECTION GUIDE
2W OUTPUT
MODEL
NUMBER
INPUT
OUTPUT
OUTPUT
VOLTAGE
VOLTAGE
CURRENT
(VDC)
(VDC)
(mA)
INPUT
CURRENT(mA)
FULL
NO
LOAD
LOAD
EFF
ISOLATION
(%)
(VDC)
PUS-0503.3-2W
5
3.3
500
452
40
73
1000
PUS-0505-2W
5
5
400
520
40
77
1000
PUS-0509-2W
5
9
222
506
40
79
1000
PUS-0512-2W
5
12
167
500
40
80
1000
PUS-0515-2W
5
15
133
488
40
82
1000
PUD-0505-2W
5
+/-5
+/-200
520
40
77
1000
PUD-0512-2W
5
+/-12
+/-84
500
40
80
1000
PUD-0515-2W
5
+/-15
+/-67
488
40
82
1000
PUS-1203.3-2W
12
3.3
500
185
15
74
1000
PUS-1205-2W
12
5
400
214
15
78
1000
PUS-1209-2W
12
9
222
214
15
78
1000
PUS-1212-2W
12
12
167
200
15
83
1000
PUS-1215-2W
12
15
133
196
15
85
1000
PUD-1205-2W
12
+/-5
+/-200
214
15
78
1000
PUD-1212-2W
12
+/-12
+/-84
200
15
83
1000
PUD-1215-2W
12
+/-15
+/-67
196
15
85
1000
PUS-2403.3-2W
24
3.3
500
92
10
74
1000
PUS-2405-2W
24
5
400
107
10
78
1000
PUS-2409-2W
24
9
222
107
10
78
1000
PUS-2412-2W
24
12
167
103
10
81
1000
PUS-2415-2W
24
15
133
101
10
83
1000
PUD-2405-2W
24
+/-5
+/-200
107
10
78
1000
PUD-2412-2W
24
+/-12
+/-84
103
10
81
1000
PUD-2415-2W
24
+/-15
+/-67
101
10
83
1000
Note: Other input to output voltages may be available. Please contact factory.
ORDERING INFORMATION:
FOR EXAMPLE:
PUS-****-2W(2W SINGLE OUTPUT)
PUD-****-2W(2W DUAL OUTPUT)
www.Power-Systems.de
Page: 2 / 6
Version: 4-Oct-02
DC-DC Converter UNIT
PU-2W Series ( 2 W UNREGULATED DC-DC CONVERTER)
z MECHANICAL DIMENSIONS &
RECOMMENDED FOOTPRINT DETAILS
PIN
SINGLE
DUAL
1
+Vin
+Vin
2
-Vin
-Vin
4
-Vout
-Vout
5
NP
COMMON
6
+Vout
+Vout
z SIMPLIFIED SCHEMATIC
SINGLE OUTPUT
+Vin
DUAL OUTPUT
+Vout
OSCILLATOR
DRIVER
-Vin
+Vin
OSCILLATOR
DRIVER
-Vout
+Vout
COMMON
-Vin
-Vout
www.Power-Systems.de
Page: 3 / 6
Version: 4-Oct-02
DC-DC Converter UNIT
PU-2W Series ( 2 W UNREGULATED DC-DC CONVERTER)
z TYPICAL APPLICATIONS
SINGLE OUTPUT
INPUT
OUTPUT
DUAL OUTPUT
INPUT
+Vout
+Vin
OUTPUT
+Vin
+Vout
LOAD1
LOAD
DC-DC
CONVERTER
-Vin
Common
DC-DC
CONVERTER
-Vin
-Vout
LOAD2
-Vout
z TYPICAL PERFORMANCE CUREVES
Specifications typical at TA=25 OC,nominal input voltage , rated output current unless otherwise specified.
VOUT VS LOAD(+/- 5Vout Models)
6.4
6.4
6.0
6.0
Vout(V)
Vout(V)
VOUT VS LOAD(5Vout Models)
5.6
5.2
4.8
5.6
5.2
4.8
0
100
200
300
400
0
Output Current(mA)
+/-50
+/-100
+/-150
+/-200
Output Current(mA)
VOUT VS LOAD(9Vout Models)
Vout(V)
10.4
10.0
9.6
9.2
8.8
0
56
111
167
222
Output Current(mA)
www.Power-Systems.de
Page: 4 / 6
Version: 4-Oct-02
DC-DC Converter UNIT
PU-2W Series ( 2 W UNREGULATED DC-DC CONVERTER)
VOUT VS LOAD(+/- 12Vout Models)
13.5
13.5
13.0
13.0
Vout(V)
Vout(V)
VOUT VS LOAD(12Vout Models)
12.5
12.0
11.5
SAFE
OPERATING
AREA
12.5
12.0
11.5
0
42
84
126
167
0
Output Current(mA)
+/-63
+/-84
VOUT VS LOAD(+/- 15Vout Models)
16.5
16.5
16.0
16.0
Vout(V)
Vout(V)
+/-42
Output Current(mA)
VOUT VS LOAD(15Vout Models)
15.5
15.0
14.5
15.5
15.0
14.5
0
34
67
101
133
0
Output Current(mA)
+/-17
+/-34
+/-52
+/-67
Output Current(mA)
EFFICIENCY VS LOAD
DERATING CURVE
2.5
80.0
60.0
40.0
20.0
0.0
0
20
40
60
80
100
OUTPUT POWER(W)
EFFICIENCY(%)
+/-21
1.5
1.0
0.5
0.0
-25
0
25
50
70
100
TA(degree C)
% OF RATED LOAD(%)
www.Power-Systems.de
2.0
Page: 5 / 6
Version: 4-Oct-02
DC-DC Converter UNIT
PU-2W Series ( 2 W UNREGULATED DC-DC CONVERTER)
PU-2W SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
Output filtering is required for operation. A minimum of 10uF is needed. Output
capacitance may be increased for additional filtering, not to exceed 220uF.
To meet the reflected ripple requirements of the converter, an input impedance of
less than 0.5ohm from DC to 250KHz is required.
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground
and connecting –OUT as the negative output.
FOR MORE INFORMATION CALL:
Power Systems – The Power Solution
74360 Ilsfeld-Auenstein ( Germany ) Dörnet 8
Tel: + 49 / 70 62 / 67 59 – 6
E-mail: [email protected]
Home Page: www.Power-Systems.de
www.Power-Systems.de
Page: 6 / 6
Fax: + 49 / 70 62 / 67 59 -80
Version: 4-Oct-02