RFE FRH180-250F

Radial Leaded PPTC
FRH Series
RoHS
ü
FEATURES
AGENCY RECOGNITION
•Low hold current, Solid state Radial-leaded product ideal for
•UL (E211981)
•C-UL (E211981)
•TÜV (R50004084)
up to 60V/250V/600V
•Application: Telecommunication and Data transmitting
•Operation Current: 0.08A ~ 0.18A
•Maximum Voltage: 60V/250V/600V
•Temperature Range: -40°C to 85°C
ELECTRICAL CHARACTERISTICS (23°C)
Part Number
Hold
Current
Trip
Current
Max. Time Maximum
to Trip
Current
Max. Oper.
Voltage
Max. Int.
Voltage
Resistance Tolerance
RMIN
R1MAX
IH, A
IT, A
A
Sec
IMAX, A
VMAX, VDC
VI-MAX, V
OHMS
OHMS
FRH080-250UF
0.08
0.16
0.35
4.0
3.0
60
250
14.0
33.0
FRH080-250F
0.08
0.16
0.35
4.0
3.0
60
250
14.0
33.0
FRH110-250UF
0.11
0.22
1.0
2.0
3.0
60
250
5.0
16.0
FRH110-250F
0.11
0.22
1.0
2.0
3.0
60
250
5.0
16.0
FRH120-250UF
0.12
0.24
1.0
2.0
3.0
60
250
6.0
16.0
FRH120-250F
0.12
0.24
1.0
2.0
3.0
60
250
4.0
16.0
FRH145-250UF
0.15
0.29
1.0
2.5
3.0
60
250
3.5
12.0
FRH145-250F
0.15
0.29
1.0
2.5
3.0
60
250
3.0
12.0
FRH180-250UF
0.18
0.65
1.5
10.0
10.0
60
250
0.8
4.0
FRH180-250F
0.18
0.65
1.5
11.0
10.0
60
250
0.8
4.0
FRH150-600F
0.15
0.30
1.0
5.0
3.0
60
600
6.0
22.0
FRH160-600F
0.16
0.32
1.0
7.0
3.0
60
600
4.0
18.0
IH=Hold current-maximum current at which the device will not trip at 23°C still air.
IT=Trip current-maximum current at which the device will always trip at 23°C still air.
V MAX=Maximum voltage device can withstand without damage at its rated current.
VI-MAX=Maximum interrupt voltage device can withstand for short period of time. (Not for long term.)
I MAX=Maximum fault current device can withstand without damage at rated voltage (V MAX).
Pd=Typical power dissipated from device when in the tripped state in 23°C still air environment.
R MIN=Minimum device resistance at 23°C.
R1MAX=Maximum device resistance at 23°C, 1 hour after tripping.
Physical specifications:
Lead material: FRH080-250~FRH180-250 Tin plated copper, 22 AWG.
FRH150-600~FRH160-600 Tin plated copper, 22 AWG.
Soldering characteristics: MIL-STD-202, Method 208E.
Insulating coating: Flame retardant epoxy, meet UL-94V-0 requirement.
Figure 1
FRH PRODUCT DIMENSIONS (MILLIMETERS)
NOTE: All FRH products are designed to assist equipment to pass ITU,
UL1950 or GR1089 specification.
Part
A
Number
B
C
D
E
Maximum Maximum Typical Minimum Maximum
FRH080-250UF
4.8
9.1
5
4.7
3.8
FRH080-250F
5.3
9.6
5
4.7
4.6
FRH110-250UF
5.3
9.4
5
4.7
3.8
FRH110-250F
5.8
9.9
5
4.7
4.6
FRH120-250UF
6.0
10.0
5
4.7
3.8
FRH120-250F
6.5
11.0
5
4.7
4.6
FRH145-250UF
6.0
10.0
5
4.7
3.8
FRH145-250F
6.5
11.0
5
4.7
4.6
FRH180-250UF
10.4
12.6
5
4.7
3.8
FRH180-250F
10.9
13.6
5
4.7
4.6
FRH150-600F
13.5
12.6
5
4.7
6
FRH160-600F
16.0
12.6
5
4.7
6
Lead Size: 22AWG (0.65mm)
Figure 2
Lead Size: 22AWG (0.65mm)
CAUTION: FRH devices are not intended for continous use of Line Voltage such as 120 VAC`600VAC and above.
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected]
C5EB08
REV 2007.03.1
Radial Leaded PPTC
FRH Series
RoHS
ü
THERMAL DERATING CURVE
Percent of Rated Hold and Trip
Current
Thermal Derating Curve - FRH Series
200%
150%
100%
50%
0%
-40
-20
0
20
40
60
80
Ambient Temperature (C)
TYPICAL TIME-TO-TRIP AT 23°C
1000
Time-to-trip (S)
100
10
G
E
F
D
C
B
A
1
0.1
A=
B=
C=
D=
E=
F=
G=
FRH080(U)-250
FRH110(U)-250
FRH120(U)-250
FRH145(U)-250
FRH180(U)-250
FRH150-600
FRH160-600
0.01
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2
2.4
2.6
2.8
3
Fault current (A )
CAUTION: FRH devices are not intended for continous use of Line Voltage such as 120 VAC`600VAC and above.
NOTE: All Specification subject to change without notice.
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected]
C5EB08
REV 2007.03.1