RFHIC 2F1G27P

CATV Line Amplifier 2F1G27P
Product Features
Application
• GaAs Push Pull
• Extremely Low Distortion
• Guaranteed Broadband Power Gain
• Heat Sink 99.9% Copper, & Gold Plated
• Excellent Thermal Conductivity
• Single Supply Voltage @ 24V
• Low DC Power Consumption
• Optimal Reliability
• CATV Trunk Amplifier
• Optical Drive Amplifier
Package Type: SOT-115J
Description
Hybrid Push Pull amplifier for CATV Systems up to 1000MHz in frequency.
This hybrid amplifier module operates with a single voltage supply of 24V(DC), and use GaAs MMIC technology.
Quick Reference Data
SYMBOL
PARAMETER
Gp
Power Gain
Itot
Total Current Consumption (DC)
CONDITIONS
MIN.
MAX.
UNIT
F = 45 MHz
26.5
27.5
dB
F = 1000 MHz
27
28.5
dB
330
mA
Vcc = 24V
Limiting Values
SYMBOL
PARAMETER
MIN.
MAX.
UNIT
Vi
RF Input Voltage (Single Tone)
-
+70
dBmV
V
DC Supply Over Voltage (5 minutes)
28
V
Tstg
Storage Temperature
-40
+100
℃
Tmb
Operating Mounting Base Temperature
-20
+100
℃
Functional Diagram
▪ Tel : 82-31-250-5011
▪ All specifications may change without notice.
▪ [email protected]
▪ Document Version 1.3
CATV Line Amplifier 2F1G27P
CHARACTERISTICS
SYMBOL
PARAMETER
Gp
Power Gain
Bandwidth 45 to 1000MHz; VCC = 24V; Tcase = 25℃; ZS = ZL = 75Ω
CONDITIONS
MIN
TYP
MAX
UNIT
f = 45 MHz
26.5
-
-
dB
f = 1000 MHz
27
-
-
dB
SL
Slope Cable Equivalent
f = 45 to 1000 MHz
-
0.5
-
dB
FL
Flatness of Frequency Response
f = 45 to 1000 MHz
-
-
0.5
dB
-
-
dB
S11
Input Return Loss
S22
Output Return Loss
F
Noise Figure
Itot
Total Current Consumption (DC)
DISTORTION
f = 45 to 80 MHz
18.0
f = 80 to 160 MHz
17.0
-
-
dB
f = 160 to 320 MHz
17.0
-
-
dB
f = 320 to 640 MHz
16.0
-
-
dB
f = 640 to 1000 MHz
16.0
-
-
dB
f = 45 to 80 MHz
18.0
-
-
dB
f = 80 to 160 MHz
17.0
-
-
dB
f = 160 to 320 MHz
17.0
-
-
dB
f = 320 to 640 MHz
16.0
-
-
dB
f = 640 to 1000 MHz
16.0
-
-
dB
f = 45 to 1000 MHz
3.0
-
4.5
dB
290
310
330
mA
Bandwidth 45 to 870MHz; VCC = 24V; Tcase = 25℃; ZS = ZL = 75Ω
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNIT
CTB
Composite Triple Beat
135 channel flat; Vo = 40dBmV
-
-66
-61
dBc
XMOD
Cross Modulation
135 channel flat; Vo = 40dBmV
-
-66
-59
dBc
CSO
Composite Second Order Distortion
135 channel flat; Vo = 40dBmV
-
-70
-60
dBc
Notes;
135 Channels, NTSC frequency raster: 55.25MHz to 859.25MHz, +40dBmV flat output level.
CTB, XMOD, CSO definitions follow NCTA definition
ESD PROTECTION
Gallium Arsenide Integrated Circuits are sensitive to electrostatic discharge (ESD) and can be damaged by static electricity.
Proper ESD control techniques should be used when handling these devices. Some of the precautions recommended are;
- Person at a workbench should be earthed via a wrist strap and a resistor.
- All mains-powered equipment should be connected to the mains via an earth-leakage switch.
- Equipment cases should be grounded.
- Relative humidity should be maintained between 40% and 50%.
- An ionizer is recommended.
- Keep static materials, such as plastic envelopes and plastic trays etc. away from the workbench.
▪ Tel : 82-31-250-5011
▪ All specifications may change without notice.
▪ [email protected]
▪ Document Version 1.3
CATV Line Amplifier 2F1G27P
NOTES FOR CORRECT USE
1.
47㎌
+24V
+
On the power input port (Pin#5), 47uF/35V capacitor GND is
recommended.
2. The heat sink of CATV Hybrids is to be mounted in direct contact
with the metal case of the equipment. Heat conducting grease should
be applied to the module/equipment interface and the unit tightly
secured.
3. Put the power off before adjusting in/output matching of the system.
4. The unit must have a common ground with the equipment and the
analyzer.
5. Pay close attention to the input voltage not to over power the hybrid.
6. The space between bottom of socket and the tip of the lead is
recommended to have space of 2mm+ to protect the pin
7. Do not open the plastic cover to change the matching inside the
hybrid. Once opened, RFHIC will not be responsible for the hybrid.
8. This CATV Hybrid amplifier is designed with GaAs technology and
can be damaged by electrical shock. To protect the device from
excessive AC input, user should use a high pass filter(Note 1) at the
in/output port of the hybrid amp or use a diplexer filter at the in/output
port of the system/equipment to be on the safe side.
Note 1. Recommend High Pass Filter
Recommended Filter
Specification @ 25℃
Cutoff Frequency
45 MHz
Bandwidth
45 ~ 1000 MHz
Return Loss
15 dB Min.
Attenuation
@ DC ~ 20 MHz
In/Out Impedance
25 dBc Min
75 ohm
▪ Tel : 82-31-250-5011
▪ All specifications may change without notice.
▪ [email protected]
▪ Document Version 1.3
CATV Line Amplifier 2F1G27P
Package Dimensions (Type: SOT-115J)
Pin No.
Function
1
2, 3, 7, 8
5
9
RF Input
Ground
Vcc
RF Output
RFHIC Corporation (RFHIC) reserves the right to make changes to any products herein or to discontinue any product at any time without notice. RFHIC do not
assume any liability for the suitability of its products for any particular purpose, and disclaims any and all liability, including without limitation consequential or
incidental damages. The product specifications herein expressed have been carefully checked and are assumed to be reliable. However, RFHIC disclaims liability for
inaccuracies and strongly recommends buyers to verify that the information they are using is current before placing purchase orders. RFHIC products are not
intended for use in life support equipment or application where malfunction of the product can be expected to result in personal injury or death. Buyer uses or sells
such products for any such unintended or unauthorized application, buyer shall indemnify, protect and hold RFHIC and its directors, officers, stockholders,
employees, representatives and distributors harmless against any and all claims arising out of such use. RFHIC’s liability under or arising out of damages, claims of
whatsoever kind and nature which RFHIC products could cause shall be limited in amount to the net purchase price of the products sold to buyer by RFHIC.
▪ Tel : 82-31-250-5011
▪ All specifications may change without notice.
▪ [email protected]
▪ Document Version 1.3