RHOMBUS-IND L-1012

Common Mode Inductor
Parameter
Min.
Inductance 1
3.3
Max.
mH
DCR (Per winding)
2.0
ARMS
Leakage Inductance1
40
µH
Interwinding capacitance1
20
pF
250 VAC, 50/60 Hz.
Hipot (Isolation) 2000 VAC.
Ω
0.3
Current2
SRF
Rated Voltage
Units
Insulation Resistance
100MΩ @ 500V
0
Temperature Rise 55 C Max.
Operating
Temperature Range -250C to +600C.
500 kHz Typ.
1. Inductance tested at 100mVRMS and 10 kHz
2. Rated current: Specified at max. temp. rise.
Schematic Diagram
Physical Dimensions
inches (mm)
.709
(18.0)
TYP
1
4
2
3
.886
(22.5)
TYP
.846
(21.5)
MAX.
.16
(4.0)
TYP.
.03
(0.7)
TYP.
.394
(10.0)
TYP.
.519
(13.0)
TYP.
2
3
1
4
RHOMBUS P/N: L-1012
CUST P/N:
NAME:
DATE: 5/05/01
SHEET:
Rhombus
Industries Inc.
Transformers & Magnetic Products
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971