RHOMBUS-IND L

Common Mode Inductor
Parameter
Min.
Inductance*
Typ.
Max.
16.00
Designed to prevent noise
emission in switching power
supplies at input.
Units
mH
DCR
Current
0.500
Ω
0.8
Amps
Leakage Inductance*
90
µH
SRF
391
kHz
Windings balanced to 1%
Rated Voltage
250 VAC
Hipot (Isolation) 2500 VAC
Insulation Resistance 100MΩ
*Inductance tested at 100mVRMS and 10 kHz
400C Temp. Rise
2mm center flange.
3mm Creepage and Clearance
from terminations to core for
International Safety Compliance.
Operating Temperature: These parts are
made with UL Class B rated materials
and can be safely operated up to 130OC.
Physical Dimensions
inches (mm)
Schematic
Diagram
1
10
5
6
RHOMBUS P/N: L-14014
CUST P/N:
DATE: 5/05/01
Rhombus
Industries Inc.
Transformers & Magnetic Products
NAME:
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971