RHOMBUS-IND L

Through hole Self-Leaded Inductor
150 kHz
Electrical Specifications at 25OC.
Part
Number
L (1)
with DC
( µH )
L-20578
250
Operating Temp. Range: -30OC to +130OC
IDC (1)
(Amps)
E-T (1)
Product
( V-µs )
DCR
max.
(Ω)
1.5
72.6
0.23
Schematic Diagram
1) Typical values for a 55OC Temperature rise at 150 kHz and
E-T value above, the core loss is 10 % of copper loss.
Physical Dimensions
inches (mm)
Min.
Typ.
A
Max.
.85 (21.6)
B
.440 (11.18)
.460 (11.68)
C
.820 (20.83)
.840 (21.34)
D
.415 (10.54)
E
.130 (3.30)
F
.300 (7.62)
Leads are #24 AWG
RHOMBUS P/N: L-20578
CUST P/N:
DATE: 01/03/01
NAME:
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com