COMMOND MODE CHOKE SURFACE MOUNT Improved EMI performance for FCC class B applications. Line to line Isolation: 500 Vrms Maximum common mode attenuation at 1 MHz Well suited for many Telecom applications Electrical Specifications at 25OC Part L Number (mH) + 30% L-583 Common Mode Attenuation @ 100 kHz @1MHz 10 MHz Isolation Voltage dB TYP dB TYP. dB TYP. (Vrms MIN.) 4.7 40 51 38 500 1.0 Physical Dimensions inches (mm) 4 DCR (Ω MAX.) Schematic Diagram 3 1 4 2 3 L-583 XXXX 1 2 White Dot Indicate Pin #1 .250 (6.35) Max. .15 (3.81) .400 (10.16) Max. .300 (7.62) .046 (1.16) DIA. 4 Each .245 (6.22) .345 (8.76) Max. RHOMBUS P/N: L-583 CUST P/N: DATE: 4/28/00 Rhombus Industries Inc. Transformers & Magnetic Products www.rhombus-ind.com NAME: SHEET: 1 OF 1 15801 Chemical Lane, Huntington Beach, CA 92649 Phone: (714) 898-0960 FAX: (714) 896-0971