RHOMBUS-IND T-1324

PARAMETER
T-1324
UNITS
Power Rating
Secondary Rating
With Load (pins 5-8)
(Input 120V Primary @60 Hz)
2.4
VA
12.0 + 5%
200
V
mA
EI PC Power
Transformer
85 %
Typ.
Schematic Diagram
Efficiency
DCR Primary (pins 1-4)
330 Typ.
Ω
DCR Secondary (pins 5-8)
5.8 Typ.
Ω
Isolation
1,4 to 5,8
4000 min.
1
5
PRI
SEC
VRMS
4
8
Manufactured with UL Listed materials.
Split Bobbin Construction, Non-Concentric
Winding Eliminates the need for Electrostatic
Sheilding.
Center Flange Insulation Barrier provides High
Insulation and low capacitive coupling, thereby
minimizing line noise and false triggering.
C
B
D
4
8
E
A
Physical Dimensions
inches (mm)
1
5
F
Lead Length .200" typ.
Size
(VA)
2.4
A
1.375
B
1.187
Dimensions in Inches
C
D
E
1.125
1.87
0.7505
12/3/99
Rhombus
Industries Inc.
Transformers & Magnetic Products
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 z FAX: (714) 896-0971