RHOMBUS-IND T-1417

Transformer
Turns Ratio
1 : 1 +1%
Parameter
Min.
Inductance 1-5
1
Typ.
Max.
1.6
Units
mH
11
µH
DC Resistance (1-4)
1.26
Ω
DC Resistance (2-5)
1.25
Ω
60
mA
Insertion Loss @28kHz
0.50
dB
Frequency Response
@10kHz-300kHz, 28kHz Ref.
+0.5
dB
Leakage Inductance
2
Current
Hi-Pot Primary to Secondary
Schematic Diagram
1500
1
10
5
6
Designed to meet UL1950
(Double Insulation)
VRMS
Materials used in construction of this
component meet or exceed UL Class B
and can be operated up to 130oC
1..Tested at 20 kHz and 100 mV
2..Pins 1-5, and 10-6 Shorted.
Tested at 100kHz - 100 mV.
Dimensions in Inches (mm)
.522
(13.26)
MAX.
.715
(18.15)
.532
(13.51)
MAX.
1
10
2
.516
(13.1)
MAX.
Suggested
Pad Layout
3
4
.100
(2.54)
.028
(0.70)
.025
(0.64)
8
7
5
.050
(1.27)
TYP.
6
.100
(2.54)
TYP.
.516
(13.1)
9
.100
(2.54)
TYP.
.675 (17.15)
.663 (16.85)
RHOMBUS P/N: T-1417
CUST P/N:
DATE:
10/27/99
Rhombus
Industries Inc.
Transformers & Magnetic Products
NAME:
SHEET:
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
www.rhombus-ind.com
FAX: (714) 896-0971