Transformer Turns Ratio 1 : 1 +1% Parameter Min. Inductance 1-5 1 Typ. Max. 1.6 Units mH 11 µH DC Resistance (1-4) 1.26 Ω DC Resistance (2-5) 1.25 Ω 60 mA Insertion Loss @28kHz 0.50 dB Frequency Response @10kHz-300kHz, 28kHz Ref. +0.5 dB Leakage Inductance 2 Current Hi-Pot Primary to Secondary Schematic Diagram 1500 1 10 5 6 Designed to meet UL1950 (Double Insulation) VRMS Materials used in construction of this component meet or exceed UL Class B and can be operated up to 130oC 1..Tested at 20 kHz and 100 mV 2..Pins 1-5, and 10-6 Shorted. Tested at 100kHz - 100 mV. Dimensions in Inches (mm) .522 (13.26) MAX. .715 (18.15) .532 (13.51) MAX. 1 10 2 .516 (13.1) MAX. Suggested Pad Layout 3 4 .100 (2.54) .028 (0.70) .025 (0.64) 8 7 5 .050 (1.27) TYP. 6 .100 (2.54) TYP. .516 (13.1) 9 .100 (2.54) TYP. .675 (17.15) .663 (16.85) RHOMBUS P/N: T-1417 CUST P/N: DATE: 10/27/99 Rhombus Industries Inc. Transformers & Magnetic Products NAME: SHEET: 15801 Chemical Lane, Huntington Beach, CA 92649 Phone: (714) 898-0960 www.rhombus-ind.com FAX: (714) 896-0971