RHOMBUS-IND T

10BASE T ISOLATION TRANSFORMER
Turns Ratio
+2%
Designed to meet or exceed IEEE
802.3, 10 Base-T specifications
1CT : 2CT & 1CT : 1CT
PARAMETER
MIN.
Open Circuit Inductance
Oscillation Voltage = 20mV
Oscillation Frequency = 100.0 KHz
MAX.
µHy
112
Leakage Inductance
Oscillation Level = 100mV
Oscillation Frequency = 100.0 KHz
0.3
µHy
Interwinding Capacitance (CW/W)
Oscillation Frequency = 100.0 KHz
8
pF
DC Resistance
0.8
ohms
Hi-Pot
Surface mount, IC grade, transfermolded package withstands 235oC
peak temperature profile
UNITS
1500
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
VRMS
Parts shipped in anti-static
tubes. 33 pieces per tube
Primary Pins 1-3 & 6-8
PHYSICAL DIMENSIONS
All dimensions in inches (mm):
SCHEMATIC DIAGRAM
1
16
2
15
3
14
13
6
11
7
10
8
9
12
RHOMBUS P/N: T-14951
CUST P/N:
DATE: 10/27/99
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
NAME:
SHEET: 1 OF 1
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971