RSG CHB75

E
R
I
E
S
Specifications
CHB75
37.5 TO 75 WATT WIDE INPUT
DC-DC CONVERTERS
SINGLE OUTPUT
Features
37.5W-75W Isolated Output
Efficiency to 85%
300KHz Switching Frequency
2 : 1 Input Range
•
•
•
•
GENERAL SPECIFICATIONS:
Input Voltage Range........................................................ 12V............9-18V
24V............18-36V
48V............ 36-75V
Undervoltage lockout .............................. 12Vin power up ...............8.8V
power down .................8V
24Vin power up ............... 17V
power down ............. 16V
48Vin power up ............... 34V
power down ............. 32.5V
Positive Logic Remote ON/OFF ( see note 3 & 4 )
Input Filter ......................................................................................... PI Type
Efficiency....................................................................................See Table
Isolation Voltage ...........................Input/Output............. 1500VDC min.
Input/Case................ 1500VDC min.
Output/Case............. 1500VDC min.
Isolation Resistance ............................................................ 107 ohm min.
Switching Frequency .................(12/24)Vin......................... 400KHz ,Typ.
48Vin................................. 300KHz ,Typ.
Operating case Temperature ....................................... -40˚C to 100˚C
Storage Temperature ................................................... -55˚C to +105˚C
Thermal Shutdown, Case Temp. .............................................100˚C Typ.
Dimensions ............................................................2.28x2.40x0.50 inches
(57.9x61.0x12.7 mm)
Case Material ......................................................................... Aluminum
OUTPUT SPECIFICATIONS:
Only for Nominal Input Voltage 24 & 48 VDC
•
•
•
•
INPUT SPECIFICATIONS:
Regulated Outputs
Continuous Short Circuit Protection
Five-Sided Metal Case
Industry Standard Half-Brick Package
Voltage Accuracy : ..................................................................... ±1% max.
Transient Response :25% Step Load Change ..........................<500µ sec.
External Trim Adj. Range ......................................................................±10%
Ripple & Noise, 20MHz BW, 2.5V & 3.3V & 5V .............. 20mV RMS., max.
75mV pk-pk, max.
12V & 15V .......................... 30mV RMS., max.
100mV pk-pk, max.
24V .......................... 100mV RMS., max.
240mV pk-pk, max.
Temperature Coefficient............................................................ ±0.03%/˚C
Short Circuit Protection..............................................................Continuous
Line Regulation1 ..........................................................................±0.2% max.
Load Regulation2 .......................................................................±0.2% max.
Over Voltage Protect trip Range, % Vo nom.............................115-140%
Current Limit .................................................110% ~150% Nominal Output
CHB75
S
NOTE:
1. Measured From High Line to Low Line.
2. Measured From Full Load to Zero Load.
3. Logic Compatibility ............... Open Collector ref to -Input
Module ON ............. Open Circuit
Module OFF ............... < 0.8Vdc
4. Suffix "N" to the Model Number with Negative Logic Remote
ON/OFF.
CASE HB
MODEL
NUMBER
INPUT
VOLTAGE
OUTPUT
VOLTAGE
2.5 VDC
CHB75-12S25
CHB75-12S33
CHB75-12S05
OUTPUT
CURRENT
INPUT CURRENT
NO LOAD
FULL LOAD
15A
3.3 VDC
15A
5 VDC
15A
4110 mA
%EFF
All Dimensions In Inches(mm)
Tolerances
76
5290 mA
78
7715 mA
81
50 mA
9-18 VDC
CASE
Inches
Millimeters
Mounting Inserts
M3*0.5 Through 4pl.
HB
CHB75-12S12
12 VDC
6.25A
7440 mA
84
CHB75-12S15
15 VDC
5A
7440 mA
84
CHB75-12S24
24 VDC
3.13A
7440 mA
84
CHB75-24S25
2.5 VDC
15A
2029 mA
77
.XX±.02
.X±.5
1.40
(35.56)
2.00
(50.8)
CHB75-24S05
3.3 VDC
15A
5 VDC
15A
79
3810 mA
82
50 mA
18-36 VDC
4
5
3
6
0.60
(15.24)
7
8
2
9
12 VDC
6.25A
3675 mA
85
CHB75-24S15
15 VDC
5A
3675 mA
85
CHB75-24S24
24 VDC
3.13A
3640 mA
86
CHB75-48S25
2.5 VDC
15A
1015 mA
77
CHB75-48S05
3.3 VDC
15A
5 VDC
15A
36-75 VDC
CHB75-48S12
12 VDC
6.25A
CHB75-48S15
15 VDC
CHB75-48S24
24 VDC
50 mA
1305 mA
79
1883 mA
83
1838 mA
85
5A
1838 mA
85
3.13A
1820 mA
86
2.40
(61.00)
PIN CONNECTION
Pin
Ø0.08
(2.03)
2pl.
2.28
(57.90)
0.50
(12.70)
SIDE VIEW
External Output Trim
+SENSE (8)
ELECTRONIC COMPONENTS
+SENSE (8)
Remote ON/OFF Control
TRIM DOWN
ON/OFF (2)
TRIM (7)
HB
TRIM (7)
10K ohms
TRIMPOT
TRIM UP
HIGH SIGNAL HERE
DISABLE OUTPUT
-SENSE (6)
-SENSE (6)
-VIN (4)
74
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de
■
■
+Vin
ON/OFF
CASE
-Vin
-Vout
-Sense
Trim
+Sense
+Vout
Ø0.04
(1.02)
7pl.
NOTE : 1. Nominal Input Voltage 12, 24 & 48 VDC
RSG
Function
1.
2.
3.
4.
5.
6.
7.
8.
9.
1.90
(48.25)
HB
CHB75-24S12
CHB75-48S33
73
2610 mA
0.18 min.
(4.60)
2*R1.50
BOTTOM VIEW
1
CHB75-24S33
Pin
±0.02
±0.5
.XXX±.010
.XX±.25
■
Änderungen vorbehalten / subject to change without notice
■
■
■
All Specifications Typical At Nominal Line, Full Load and 25˚C Unless Otherwise Noted.
Application Note
Remote ON/OFF Control
Derating
The CHB75 series allows the user to switch the module on and off electronically with remote on/off feature. The CHB75 series
are available with "positive logic" or "negative logic" (option).
The operating case temperature range of the CHB75 series is -40˚C to +100˚C. When operating the CHB75 , proper derating
or cooling is needed .
ON/OFF (2)
Logic State
(PIN 2)
Power Disspated, Pd (Watts)
25
Natural Convection
20 ft./min. (0.1 m/s)
20
Logic Low -
HIGH SIGNAL HERE
DISABLE OUTPUT
Power Dissipated vs Ambient Temperature and Air Flow
Switch Closed
-VIN (4)
Logic High Switch Open
100 ft./min. (0.5 m/s)
15
Negative Logic
Positive Logic
Module on
Module off
Module off
Module on
CHB75
Logic Table
Following is the derating curve of CHB75 without heat sink
200 ft./min. (1.0 m/s)
10
300 ft./min. (1.5 m/s)
5
External Output Trimming
400 ft./min. (2.0 m/s)
Output may optionally be externally trimmed
0
0
10
20
40
30
50
60
70
80
90
100
+SENSE (8)
+SENSE (8)
(±10%) with a fixed resistor or an external trimpot as shown.
TRIM DOWN
Ambient Temperature, Ta(Deg. C)
TRIM (7)
TRIM (7)
10K ohms
TRIMPOT
Forced Convection Power Derating with No Heat Sink
TRIM UP
-SENSE (6)
-SENSE (6)
Where:
The power dissipation (Pd):
Pd = Pi - Po = Po (1-
)/
Output Noise
The thermal resistance are list below:
Chart of Thermal Resistance vs Air Flow:
The output noise is measured with 10µF tantalum capacitor and 1.0µF ceramic capacitor across output.
AIR FLOW RATE
TYPICAL Rca
Natural Convection
7.12 ˚C/W
100 ft./min.
6.21 ˚C/W
200 ft./min.
5.17 ˚C/W
300 ft./min.
4.29 ˚C/W
400 ft./min.
3.64 ˚C/W
+Vout (9)
Ceramic
1.0µF
Resistor
Load
The temperature rise (
T ):
Solid tantalum
10µF
T = Pd * Rca
To
Scope
-Vout (5)
Output Noise Test Circuit schematic
75
76
All Specifications Typical At Nominal Line, Full Load and 25˚C Unless Otherwise Noted.
75 WATT WIDE INPUT DC-DC
CONVERTERS DUAL OUTPUT
●
●
●
●
●
●
●
●
75W Isolated Output
Efficiency to 84%
400KHz Switching Frequency
2 : 1 Input Range
Regulated Outputs
Continuous Short Circuit Protection
Industrial Standard Half-Brick Package
Total power 75W with 15A Maximum Per
Channel
VIn
Model Num
CHB75-48D05- 36-75 VDC
2V5
CHB75-48D05- 36-75 VDC
3V3
Note:
VOut
5.0
2.5
5.0
3.3
VDC
VDC
VDC
VDC
IOut Min
1
0
1
0
IOut Max
INo Load
A 15000.0 mA
A
A 15000.0 mA
A
IFull Load
30.0 mA
1.86 A
Eff Case
84% HB
30.0 mA
1.86 A
84%
1. Nominal Input Voltage : 48 VDC
2. Measured with 15A load on VO1
SPECIFICATIONS
Input Specifications
Input Voltage Range
Under voltage lockout
Positive Logic Remote ON/OFF ( see note 3 & 4 )
Input Filter
48V----------36-75V
48Vin power up----------34V
48Vin power down----------32.5V
PI Type
Output Specifications
Voltage Accuracy
Transient Response:25% Step Load Change
External Trim Adj. Range
Ripple & Noise, 20MHz BW
2.5V & 3.3V & 5V
Temperature Coefficient
Short Circuit Protection
Line Regulation1, Single/Dual
Load Regulation2, Single/Dual
Over Voltage Protection trip Range ,% Vo nom
Current Limit3
+/-2.0% max.
<500us
+/- 5.0%
40mV RMS, max.
100mV pk-pk, max.
+/- 0.03%/ oC
Continuous
+/-0.2% max.
+/-0.5% max.
115-140%
110% ~140% Nominal Output
General Specifications
Efficiency
Isolation Voltage Input/Output
Input/Case
Output/Case
Isolation Resistance
Switching Frequency
Operating Case Temperature
Storage Tempterature
Thermal Shutdown, Case Temp
Dimensions
See Table
1500VDC min.
1500VDC min.
1500VDC min.
107 ohms min.
400KHz ,Typ.
-40oC to +100oC
-55oC to +105oC
100oC Typ
2.28X2.40X0.50 inches
(57.9X61.0X12.7mm)
HB
Case Material
Aluminum baseplate with plastic
case
Notes
1.
2.
3.
4.
5.
6.
Measured From High Line to Low
Line
Measured From Full Load to Min.
Load
Measured with Output Current on
Output1 (VO1)
Logic Compatibility ---------- Open
Collector ref to -Input
Module ON ---------- Open Circuit
Module OFF --------- < 0.8Vdc
Suffix "N" to the Model Number
with Negative Logic Remote
ON/OFF
The output noise is measured with
10uf tantalum and
1uf ceramic capacitor across
output.
All specifications typical at nominal line, full load, and 25oC unless otherwise noted.