SCHURTER 6762-H-ABCN-D-EGOP

6762
Power entry modules without line filter
www.schurter.com/pg05
IEC Appliance Inlet C14 or C18 with Line Switch 2 pole and Fuseholder 2-pole
C14
C18
70° C
70° C
Description
Characteristics
-Panel Mount:
Snap-in or screw-on mounting, from front side Appliance Inlet, protection class I or II, Fuseholder for fuse-links 5 x 20 mm, Line Switch 1‑ or
2‑pole
-Solder terminals or quick connect terminals
-Line switch non-illuminated or illuminated
References
General Product Information
Weblinks
Approvals, RoHS, CHINA-RoHS, Mating Connectors, Distributor-StockCheck, Accessories
Approvals
-VDE License Number: 40013344
-UL License Number: E88880
-CSA License Number: 1084381
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
10 A / 250 VAC; 50 Hz
10 A / 250 VAC; 60 Hz
> 3 kVAC between L-N
> 1.5 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
from front side IP 20 acc. to IEC 60529
Suitable for appliances with protection
class 1 or 2 acc. to IEC 61140
Solder terminals or quick connect terminals
Screw
Mounting screw torque max 0.5 Nm
Snap-in1.0 - 1.5/2.0 - 2.5 mm
black, UL 94V-0
Appliance Inlet
Fuseholder
Power Acceptance @ Ta >
23°C
Line Switch
Dimensions
C14 acc. to IEC/EN 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1 or 2
1-pole, acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
Admissible power acceptance at higher ambient temperature see derating
curves
Rocker switch 1 or 2 pole, non-illuminated or illuminated black, acc. to IEC
61058-1
Technical details
50 mm
25.5
+0.2
27.4 - 0
27.2
ø
58.9 - 0
58.7
63
65
+0.2
50
2
3.
R
40
3
3
R
28
3
40
5
Lenght of the terminal please find at the order code configuration table Connectors
6762
Power entry modules without line filter
www.schurter.com/pg05
Config. Code
Product Configurator
6762|-|H|-|A|B|C|N|-|D|-|E|G|O|P|
The characters are placeholders for the correspondingly keys of selections from the key tables. 6762|-| H |-|A|B|C|N|-|D|-|E|G|O|P| = Type
Type
6762|-|H|-|A|B|C|N|-| D |-|E|G|O|P| = Color
Configuration
key
protection class 2
B
protection class 1
X
Color
Configuration
key
jet black; RAL9005
A
standard color: black
6762|-|H|-| A |B|C|N|-|D|-|E|G|O|P| = Terminals
Terminal L
6762|-|H|-|A|B|C|N|-|D|-| E |G|O|P| = Style
Configuration
key
solder terminal
long solder terminal (L=8,5mm)
Style
Configuration
key
1
flange with countersunk holes
1
3
flange with through holes
2
snap-in standard type
3
insert type
5
blade terminal (2,8x0,8mm)
7
blade terminal (4,8x0,8mm)
8
blade terminal (6,3x0,8mm)
9
6762|-|H|-|A|B|C|N|-|D|-|E| G |O|P| = Dimension X
Dimension "X"
6762|-|H|-|A| B |C|N|-|D|-|E|G|O|P| = Terminals
Configuration
key
00
Terminal N
Configuration
key
solder terminal
1
long solder terminal (L=8,5mm)
3
blade terminal (2,8x0,8mm)
7
blade terminal (4,8x0,8mm)
8
blade terminal (6,3x0,8mm)
9
The dimension "X" is dispalyed in (1/10 mm). This information is also valid for the
order code
6762|-|H|-|A|B|C|N|-|D|-|E|G| O |P| = Features
Features
Symbols similar as in table A
6762|-|H|-|A|B| C |N|-|D|-|E|G|O|P| = Terminals
Terminal Ground
dead cover
1
holder for 1 fuse (text legible, when inlet on top)
2
holder for 1 fuse (text legible, when inlet on bottom)
3
6762|-|H|-|A|B|C|N|-|D|-|E|G|O| P | = Latching Action Switch
Configuration
key
without terminal
0
solder terminal
1
long solder terminal (L=8,5mm)
3
dead cover
1
blade terminal (2,8x0,8mm)
7
unipolar switch, 4,8mm blade terminal, black rocker
2
blade terminal (4,8x0,8mm)
8
unipolar switch, solder terminal, black rocker
3
blade terminal (6,3x0,8mm)
9
bipolar switch, 4,8mm blade terminal, black rocker
4
bipolar switch, solder terminals, black rocker
5
bipolar switch, 4,8mm blade terminal, rocker red illuminated
6
bipolar switch, solder terminal, rocker red illuminated
7
bipolar switch, 4,8mm blade terminals, rocker green illuminated
8
bipolar switch, solder terminals, rocker green illuminated
9
Latching Action Switch
Symbols similar as in table A
6762|-|H|-|A|B|C| N |-|D|-|E|G|O|P| = Terminal Fuseholder
Terminal Fuseholder
Configuration
key
solder terminal
1
blade terminal (4,8x0,8mm)
8
Configuration
key
Connectors
Configuration
key
6762
Power entry modules without line filter
www.schurter.com/pg05
Variants
Config. Code
Description
Order Number
6762-B-8808-A-10024 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground:
without terminal, fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: flange with countersunk holes, dimension X: 00, features: holder for 1 fuse (text legible, when inlet on top), bipolar switch, 4,8mm blade terminal, black rocker
4304.6049
6762-B-8808-A-30022 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground:
without terminal, fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: snap-in standard type, dimension X:
00, features: holder for 1 fuse (text legible, when inlet on top), unipolar switch, 4,8mm blade terminal, black rocker
4304.6050
6762-B-8808-A-30024 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground:
without terminal, fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: snap-in standard type, dimension X:
00, features: holder for 1 fuse (text legible, when inlet on top), bipolar switch, 4,8mm blade terminal, black rocker
4304.6051
6762-X-1111-A-10021 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: solder terminal, N: solder terminal, ground: solder terminal, fuseholder: solder terminal, color: jet black; RAL9005, design: flange with countersunk holes, dimension X: 00, features: holder for 1 fuse
(text legible, when inlet on top), dead cover
4304.6052
6762-X-1111-A-10024 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: solder terminal, N: solder terminal, ground: solder terminal, fuseholder: solder terminal, color: jet black; RAL9005, design: flange with countersunk holes, dimension X: 00, features: holder for 1 fuse
(text legible, when inlet on top), bipolar switch, 4,8mm blade terminal, black rocker
4304.6053
6762-X-1111-A-10025 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: solder terminal, N: solder terminal, ground: solder terminal, fuseholder: solder terminal, color: jet black; RAL9005, design: flange with countersunk holes, dimension X: 00, features: holder for 1 fuse
(text legible, when inlet on top), bipolar switch, solder terminals, black rocker
4304.6054
6762-X-1111-A-10034 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: solder terminal, N: solder terminal, ground: solder terminal, fuseholder: solder terminal, color: jet black; RAL9005, design: flange with countersunk holes, dimension X: 00, features: holder for 1 fuse
(text legible, when inlet on bottom), bipolar switch, 4,8mm blade terminal, black rocker
4304.6055
6762-X-3331-A-30025 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: long solder terminal (L=8,5mm), N: long solder terminal (L=8,5mm),
ground: long solder terminal (L=8,5mm), fuseholder: solder terminal, color: jet black; RAL9005, design: snap-in standard type,
dimension X: 00, features: holder for 1 fuse (text legible, when inlet on top), bipolar switch, solder terminals, black rocker
4304.6056
6762-X-8888-A-10021 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground:
blade terminal (4,8x0,8mm), fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: flange with countersunk
holes, dimension X: 00, features: holder for 1 fuse (text legible, when inlet on top), dead cover
4304.6057
6762-X-8888-A-10024 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground:
blade terminal (4,8x0,8mm), fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: flange with countersunk
holes, dimension X: 00, features: holder for 1 fuse (text legible, when inlet on top), bipolar switch, 4,8mm blade terminal, black
rocker
4304.6058
6762-X-8888-A-10026 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground:
blade terminal (4,8x0,8mm), fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: flange with countersunk
holes, dimension X: 00, features: holder for 1 fuse (text legible, when inlet on top), bipolar switch, 4,8mm blade terminal, rocker
red illuminated
4304.6059
6762-X-8888-A-10028 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground:
blade terminal (4,8x0,8mm), fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: flange with countersunk
holes, dimension X: 00, features: holder for 1 fuse (text legible, when inlet on top), bipolar switch, 4,8mm blade terminals, rocker
green illuminated
4304.6060
6762-X-8888-A-10034 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground: 4304.6061
blade terminal (4,8x0,8mm), fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: flange with countersunk
holes, dimension X: 00, features: holder for 1 fuse (text legible, when inlet on bottom), bipolar switch, 4,8mm blade terminal, black
rocker
6762-X-8888-A-30021 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground:
blade terminal (4,8x0,8mm), fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: snap-in standard type,
dimension X: 00, features: holder for 1 fuse (text legible, when inlet on top), dead cover
4304.6062
6762-X-8888-A-30022 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground:
blade terminal (4,8x0,8mm), fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: snap-in standard type,
dimension X: 00, features: holder for 1 fuse (text legible, when inlet on top), unipolar switch, 4,8mm blade terminal, black rocker
4304.6063
6762-X-8888-A-30024 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground:
blade terminal (4,8x0,8mm), fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: snap-in standard type,
dimension X: 00, features: holder for 1 fuse (text legible, when inlet on top), bipolar switch, 4,8mm blade terminal, black rocker
4304.6064
6762-X-8888-A-30025 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground:
blade terminal (4,8x0,8mm), fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: snap-in standard type,
dimension X: 00, features: holder for 1 fuse (text legible, when inlet on top), bipolar switch, solder terminals, black rocker
4304.6065
6762-X-8888-A-30026 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground:
blade terminal (4,8x0,8mm), fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: snap-in standard type,
dimension X: 00, features: holder for 1 fuse (text legible, when inlet on top), bipolar switch, 4,8mm blade terminal, rocker red
illuminated
4304.6066
6762-X-8888-A-30028 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground:
blade terminal (4,8x0,8mm), fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: snap-in standard type,
dimension X: 00, features: holder for 1 fuse (text legible, when inlet on top), bipolar switch, 4,8mm blade terminals, rocker green
illuminated
4304.6067
6762-X-8888-A-30036 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground:
blade terminal (4,8x0,8mm), fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: snap-in standard type,
dimension X: 00, features: holder for 1 fuse (text legible, when inlet on bottom), bipolar switch, 4,8mm blade terminal, rocker red
illuminated
4304.6068
6762-X-9991-A-30022 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (6,3x0,8mm), N: blade terminal (6,3x0,8mm), ground:
blade terminal (6,3x0,8mm), fuseholder: solder terminal, color: jet black; RAL9005, design: snap-in standard type, dimension X:
00, features: holder for 1 fuse (text legible, when inlet on top), unipolar switch, 4,8mm blade terminal, black rocker
4304.6069
The listet variants should be available from stock Other versions on request www.schurter.com/contact
Connectors
6762
Power entry modules without line filter
www.schurter.com/pg05
Config. Code
Description
Order Number
6762-X-9998-A-10024 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (6,3x0,8mm), N: blade terminal (6,3x0,8mm), ground:
blade terminal (6,3x0,8mm), fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: flange with countersunk
holes, dimension X: 00, features: holder for 1 fuse (text legible, when inlet on top), bipolar switch, 4,8mm blade terminal, black
rocker
4304.6070
6762-X-9998-A-10026 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (6,3x0,8mm), N: blade terminal (6,3x0,8mm), ground:
blade terminal (6,3x0,8mm), fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: flange with countersunk
holes, dimension X: 00, features: holder for 1 fuse (text legible, when inlet on top), bipolar switch, 4,8mm blade terminal, rocker
red illuminated
4304.6071
6762-X-9998-A-30024 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (6,3x0,8mm), N: blade terminal (6,3x0,8mm), ground:
blade terminal (6,3x0,8mm), fuseholder: blade terminal (4,8x0,8mm), color: jet black; RAL9005, design: snap-in standard type,
dimension X: 00, features: holder for 1 fuse (text legible, when inlet on top), bipolar switch, 4,8mm blade terminal, black rocker
4304.6072
6762-X-8881-A-30024 6762, IEC Power Entry Module C14, 70°C, version: 1 or 2, L: blade terminal (4,8x0,8mm), N: blade terminal (4,8x0,8mm), ground:
blade terminal (4,8x0,8mm), fuseholder: solder terminal, color: jet black; RAL9005, design: snap-in standard type, dimension X:
00, features: holder for 1 fuse (text legible, when inlet on top), bipolar switch, 4,8mm blade terminal, black rocker
4304.6120
The listet variants should be available from stock Other versions on request www.schurter.com/contact
Packaging unit 50 Pcs Mating Outlets/Connectors
Category / Description
Connector Overview complete
IEC Connector C15, Rewireable, Straight
0101
IEC Connector C15A, Rewireable, Straight
0102
IEC Connector C15A, Rewireable, Straight
0102-G
IEC Connector C15A, Rewireable, Angled
0112
IEC Connector C13, Rewireable, Angled
4012
Connector further types to 6762
...
Power Cord Overview complete
Power Cord with IEC Connector C13, Angled
0311
Power Cord with IEC Connector C13, Angled
3011
Power Cord with IEC Connector C13, Angled
3012
Power Cord with IEC Connector C13, Angled
3013
Power Cord with IEC Connector C13
3020
Power Cord further types to 6762
...
Power Supply or Interconnection Cord Overview complete
Divers Power Supply and Interconnection Cords 10 A
6000.0214
Divers Power Supply and Interconnection Cords 10 A
6000.0224
Divers Power Supply and Interconnection Cords 10 A
6003.0204
Divers Power Supply and Interconnection Cords 10 A
6003.0205
Divers Power Supply and Interconnection Cords 10 A
6003.0215
Power Supply or Interconnection Cord further types to 6762
...
The
specifications, descriptions and illustrations indicated in this document are based on
Connectors
current information. All content is subject to modifications and amendments.