EMC2301 RPM-Based PWM Fan Controller PRODUCT FEATURES Datasheet General Description Features The EMC2301 is an SMBus compliant fan controller with a PWM fan driver. The fan driver is controlled by a programmable frequency PWM driver and Fan Speed Control algorithm that operates in either a closed loop fashion or as a directly PWM-controlled device. Each closed loop Fan Speed Control algorithm (FSC) has the capability to detect aging fans and alert the system. It will likewise detect stalled or locked fans and trigger an interrupt. Additionally, the EMC2301 offers a clock output so that multiple devices may be chained and slaved to the same clock source for optimal performance in large distributed systems. — — — — — — Servers Projectors Industrial and Networking Equipment Notebook Computers 4-wire fan compatible High speed PWM (26 kHz) Low speed PWM (9.5Hz - 2240 Hz) Optional detection of aging fans Fan Spin Up Control and Ramp Rate Control Alert on Fan Stall Watchdog Timer RPM-based fan control algorithm — 0.5% accuracy from 500 RPM to 16k RPM (external crystal oscillator) — 1% accuracy from 500 RPM to 16k RPM (internal clock) SMBus 2.0 Compliant CLK Pin can provide a clock source output Available in an 8-pin MSOP Lead-free RoHS Compliant package — SMBus Alert compatible Applications Programmable Fan Control circuit (EMC2301) Block Diagram CLK TACH Tach Measurement Tachometer Limit Registers SMBus Slave Protocol PWM SMSC EMC2301 PWM Drivers SMCLK SMDATA ALERT# Fan Speed Control Algorithm DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet ORDER NUMBER: ORDERING NUMBER EMC2301-1-ACZL-TR PACKAGE FEATURES 8-pin MSOP (Lead-free RoHS compliant) One RPM-based fan speed control algorithm This product meets the halogen maximum concentration values per IEC61249-2-21 For RoHS compliance and environmental information, please visit www.smsc.com/rohs 80 ARKAY DRIVE, HAUPPAUGE, NY 11788 (631) 435-6000, FAX (631) 273-3123 Copyright © 2009 SMSC or its subsidiaries. All rights reserved. Circuit diagrams and other information relating to SMSC products are included as a means of illustrating typical applications. Consequently, complete information sufficient for construction purposes is not necessarily given. Although the information has been checked and is believed to be accurate, no responsibility is assumed for inaccuracies. SMSC reserves the right to make changes to specifications and product descriptions at any time without notice. Contact your local SMSC sales office to obtain the latest specifications before placing your product order. The provision of this information does not convey to the purchaser of the described semiconductor devices any licenses under any patent rights or other intellectual property rights of SMSC or others. All sales are expressly conditional on your agreement to the terms and conditions of the most recently dated version of SMSC's standard Terms of Sale Agreement dated before the date of your order (the "Terms of Sale Agreement"). The product may contain design defects or errors known as anomalies which may cause the product's functions to deviate from published specifications. Anomaly sheets are available upon request. SMSC products are not designed, intended, authorized or warranted for use in any life support or other application where product failure could cause or contribute to personal injury or severe property damage. Any and all such uses without prior written approval of an Officer of SMSC and further testing and/or modification will be fully at the risk of the customer. Copies of this document or other SMSC literature, as well as the Terms of Sale Agreement, may be obtained by visiting SMSC’s website at http://www.smsc.com. SMSC is a registered trademark of Standard Microsystems Corporation (“SMSC”). Product names and company names are the trademarks of their respective holders. SMSC DISCLAIMS AND EXCLUDES ANY AND ALL WARRANTIES, INCLUDING WITHOUT LIMITATION ANY AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, AND AGAINST INFRINGEMENT AND THE LIKE, AND ANY AND ALL WARRANTIES ARISING FROM ANY COURSE OF DEALING OR USAGE OF TRADE. IN NO EVENT SHALL SMSC BE LIABLE FOR ANY DIRECT, INCIDENTAL, INDIRECT, SPECIAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES; OR FOR LOST DATA, PROFITS, SAVINGS OR REVENUES OF ANY KIND; REGARDLESS OF THE FORM OF ACTION, WHETHER BASED ON CONTRACT; TORT; NEGLIGENCE OF SMSC OR OTHERS; STRICT LIABILITY; BREACH OF WARRANTY; OR OTHERWISE; WHETHER OR NOT ANY REMEDY OF BUYER IS HELD TO HAVE FAILED OF ITS ESSENTIAL PURPOSE, AND WHETHER OR NOT SMSC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Revision 1.1 (10-12-09) 2 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet Table of Contents Chapter 1 Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Chapter 2 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.1 2.2 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 SMBus Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Chapter 3 Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 3.1 3.2 System Management Bus Interface Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.1 SMBus Start Bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.2 SMBus Address and RD / WR Bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.3 SMBus Data Bytes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.4 SMBus ACK and NACK Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.5 SMBus Stop Bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.6 SMBus Time-out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.7 SMBus and I2C Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SMBus Protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.1 Write Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.2 Read Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.3 Send Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.4 Receive Byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.5 Block Write Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.6 Block Read Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2.7 Alert Response Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 12 12 12 12 13 13 13 13 13 14 14 14 14 15 15 Chapter 4 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 Fan Control Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PWM Fan Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RPM-based Fan Speed Control Algorithm (FSC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.1 Programming the RPM-based Fan Speed Control Algorithm . . . . . . . . . . . . . . . . . . . . . Tachometer Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.1 Stalled Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4.2 Aging Fan or Invalid Drive Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLK Pin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5.1 External Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5.2 Internal Clock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Spin Up Routine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ramp Rate Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Watchdog Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.8.1 Power Up Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.8.2 Continuous Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 17 17 18 18 18 19 19 19 19 19 20 21 21 22 Chapter 5 Register Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 5.1 5.2 5.3 5.4 Register Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.1 Lock Entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Status Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3.1 Fan Status - 24h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3.2 Fan Stall Status - 25h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3.3 Fan Spin Status - 26h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3.4 Fan Drive Fail Status - 27h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Interrupt Enable Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SMSC EMC2301 3 DATASHEET 23 24 25 25 26 26 26 26 27 Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet 5.5 5.6 5.7 5.8 5.9 5.10 5.11 5.12 5.13 5.14 5.15 5.16 5.17 5.18 5.19 5.20 5.21 5.22 PWM Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5.1 PWM Polarity Config - 2Ah . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5.2 PWM Output Config - 2Bh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PWM Base Frequency Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Setting Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PWM Divide Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Configuration 1 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Configuration 2 Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gain Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Spin Up Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Max Step Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Minimum Drive Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Valid TACH Count Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Drive Fail Band Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TACH Target Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TACH Reading Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Software Lock Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product ID Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Manufacturer ID Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Revision Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 27 27 28 28 29 29 30 32 32 34 34 35 35 36 36 37 37 38 38 Chapter 6 Typical Operating Curves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Chapter 7 Package Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 7.1 7.2 EMC2301 Package Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Package Markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Revision 1.1 (10-12-09) 4 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet List of Figures Figure 1.1 Figure 3.1 Figure 4.1 Figure 4.2 Figure 4.3 Figure 7.1 Figure 7.2 EMC2301 Pin Diagram (8 pin MSOP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 SMBus Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 System Diagram of EMC2301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Spin Up Routine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Ramp Rate Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 EMC2301 Package Drawing - 8-Pin MSOP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 EMC2301 Package Markings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 SMSC EMC2301 5 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet List of Tables Table 1.1 Pin Description for EMC2301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Table 1.2 Pin Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Table 2.1 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Table 2.2 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Table 2.3 SMBus Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Table 3.1 Protocol Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Table 3.2 Write Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Table 3.3 Read Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Table 3.4 Send Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Table 3.5 Receive Byte Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Table 3.6 Block Write Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Table 3.7 Block Read Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Table 3.8 Alert Response Address Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Table 4.1 Fan Controls Active for Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Table 5.1 EMC2301 Register Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Table 5.2 Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Table 5.3 Fan Status Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Table 5.4 Fan Interrupt Enable Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Table 5.5 PWM Configuration Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Table 5.6 PWM Base Frequency Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Table 5.7 PWM_BASEx[1:0] Bit Decode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Table 5.8 Fan Driver Setting Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Table 5.9 PWM Divide Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Table 5.10 Fan Configuration 1 Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Table 5.11 Range Decode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Table 5.12 Minimum Edges for Fan Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Table 5.13 Update Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Table 5.14 Fan Configuration 2 Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Table 5.15 Derivative Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Table 5.16 Error Range Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Table 5.17 Gain Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 5.18 Gain Decode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 5.19 Fan Spin Up Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Table 5.20 DRIVE_FAIL_CNT[1:0] Bit Decode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Table 5.21 Spin Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Table 5.22 Spin Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Table 5.23 Fan Max Step Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Table 5.24 Minimum Fan Drive Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Table 5.25 Valid TACH Count Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Table 5.26 Fan Drive Fail Band Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Table 5.27 TACH Target Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Table 5.28 TACH Reading Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Table 5.29 Software Lock Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Table 5.30 Product ID Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Table 5.31 Manufacturer ID Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Table 5.32 Revision Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Revision 1.1 (10-12-09) 6 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet Chapter 1 Pin Description SMDATA 1 SMCLK 2 VDD 3 GND 4 8 ALERT# EMC2301 8-MSOP 7 CLK 6 TACH 5 PWM Figure 1.1 EMC2301 Pin Diagram (8 pin MSOP) Table 1.1 Pin Description for EMC2301 PIN NUMBER PIN NAME PIN FUNCTION PIN TYPE 1 SMDATA SMBus data input/output - requires external pull-up resistor DIOD (5V) 2 SMCLK SMBus clock input - requires external pull-up resistor DI (5V) 3 VDD Power Supply Power 4 GND Ground Power Push-Pull PWM output driver for the Fan DO 5 PWM Open Drain PWM output driver for the Fan OD (5V) Open drain tachometer input for the Fan requires pull-up resistor DI (5V) Clock input for tachometer measurement DI (5V) Push-Pull Clock output to other fan controllers to synchronize Fan Speed Control DO Active low interrupt - requires external pull-up resistor. OD (5V) 6 TACH 7 CLK 8 ALERT# The pin types are described in detail below. All pins labeled with (5V) are 5V tolerant. APPLICATION NOTE: For the 5V tolerant pins that have a pull-up resistor, the voltage difference between VDD and the 5V tolerant pad must never be more than 3.6V. SMSC EMC2301 7 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet Table 1.2 Pin Types Revision 1.1 (10-12-09) PIN TYPE DESCRIPTION Power This pin is used to supply power or ground to the device. DI Digital Input - this pin is used as a digital input. This pin is 5V tolerant. DO Push / Pull Digital Output - this pin is used as a digital output. It can both source and sink current. DIOD Digital Input / Open Drain Output this pin is used as a digital I/O. When it is used as an output, it is open drain and requires a pull-up resistor. This pin is 5V tolerant. OD Open Drain Digital Output - this pin is used as a digital output. It is open drain and requires a pull-up resistor. This pin is 5V tolerant. 8 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet Chapter 2 Electrical Specifications Table 2.1 Absolute Maximum Ratings Voltage on 5V tolerant pins (V5VT_pin) -0.3 to 5.5 V Voltage on 5V tolerant pins (|V5VT_pin - VDD|) (see Note 2.1) 0 to 3.6 V Voltage on VDD pin -0.3 to 4 V Voltage on any other pin to GND -0.3 to VDD + 0.3 V Package Thermal Resistance - Junction to Ambient (θJA) 141 °C/W Operating Ambient Temperature Range -40 to 125 °C Storage Temperature Range -55 to 150 °C ESD Rating, All Pins, HBM 2000 V Note: Stresses above those listed could cause permanent damage to the device. This is a stress rating only and functional operation of the device at any other condition above those indicated in the operation sections of this specification is not implied. Note 2.1 2.1 For the 5V tolerant pins that have a pull-up resistor, the pull-up voltage must not exceed 3.6V when the EMC2301 is unpowered. Electrical Specifications Table 2.2 Electrical Specifications VDD = 3V to 3.6V, TA = -40°C to 125°C, all Typical values at TA = 27°C unless otherwise noted. CHARACTERISTIC SYMBOL MIN TYP MAX UNIT 3.3 3.6 V 350 475 uA CONDITIONS DC Power Supply Voltage VDD Supply Current IDD 3 PWM Fan Driver PWM Resolution PWM PWM Duty Cycle DUTY 256 Steps 0 100 % RPM-based Fan Controller Tachometer Range Tachometer Setting Accuracy TACH 16000 RPM ΔTACH ±0.5 ±1 % External oscillator 32.768kHz ΔTACH ±1 ±2 % Internal Oscillator Input High Voltage VIH Input Low Voltage VIL SMSC EMC2301 480 2.0 V 0.8 9 DATASHEET V Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet Table 2.2 Electrical Specifications (continued) VDD = 3V to 3.6V, TA = -40°C to 125°C, all Typical values at TA = 27°C unless otherwise noted. CHARACTERISTIC Output High Voltage Output Low Voltage SYMBOL MIN VOH VDD 0.4 TYP MAX UNIT 8 mA current drive V VOL 0.4 V 8 mA current sink ILEAK ±5 uA ALERT# pin Powered and unpowered 0°C < TA < 85°C pull-up voltage < 3.6V Leakage current Note 2.2 2.2 CONDITIONS All voltages are relative to ground. SMBus Electrical Specifications Table 2.3 SMBus Electrical Specifications VDD= 3V to 3.6V, TA = -40°C to 125°C Typical values are at TA = 27°C unless otherwise noted. CHARACTERISTIC SYMBOL MIN TYP MAX UNITS CONDITIONS SMBus Interface Input High Voltage VIH Input Low Voltage VIL Output High Voltage Output Low Voltage Input High/Low Current Input Capacitance VOH 2.0 V 0.8 VDD - 0.4 V V VOL 0.4 V 4 mA current sink IIH / IIL ±5 uA Powered and unpowered 0°C < TA < 85°C CIN 5 pF SMBus Timing Clock Frequency fSMB 10 400 kHz 50 ns Spike Suppression tSP Bus free time Start to Stop tBUF 1.3 us Setup Time: Start tSU:STA 0.6 us Setup Time: Stop tSU:STP 0.6 us Data Hold Time tHD:DAT 0.6 6 us Data Setup Time tSU:DAT 0.6 72 us Revision 1.1 (10-12-09) 10 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet Table 2.3 SMBus Electrical Specifications (continued) VDD= 3V to 3.6V, TA = -40°C to 125°C Typical values are at TA = 27°C unless otherwise noted. CHARACTERISTIC SYMBOL MIN Clock Low Period tLOW 1.3 us Clock High Period tHIGH 0.6 us Clock/Data Fall time tFALL 300 ns Min = 20+0.1CLOAD ns Clock/Data Rise time tRISE 300 ns Min = 20+0.1CLOAD ns CLOAD 400 pF per bus line Capacitive Load SMSC EMC2301 TYP MAX 11 DATASHEET UNITS CONDITIONS Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet Chapter 3 Communications 3.1 System Management Bus Interface Protocol The EMC2301 communicates with a host controller, such as an SMSC SIO, through the SMBus. The SMBus is a two-wire serial communication protocol between a computer host and its peripheral devices. A detailed timing diagram is shown in Figure 3.1. Stretching of the SMCLK signal is supported; however, the EMC2301 will not stretch the clock signal. TLOW THIGH THD:STA TSU:STO TRISE SMCLK THD:STA TFALL THD:DAT TSU:STA TSU:DAT SMDATA TBUF P S S S - Start Condition P - Stop Condition P Figure 3.1 SMBus Timing Diagram 3.1.1 SMBus Start Bit The SMBus Start bit is defined as a transition of the SMBus Data line from a logic ‘1’ state to a logic ‘0’ state while the SMBus Clock line is in a logic ‘1’ state. 3.1.2 SMBus Address and RD / WR Bit The SMBus Address Byte consists of the 7-bit client address followed by a RD / WR indicator bit. If this RD / WR bit is a logic ‘0’, then the SMBus Host is writing data to the client device. If this RD / WR bit is a logic ‘1’, then the SMBus Host is reading data from the client device. The SMBus address is set at 0101_111(r/w)b. 3.1.3 SMBus Data Bytes All SMBus Data bytes are sent most significant bit first and composed of 8-bits of information. 3.1.4 SMBus ACK and NACK Bits The SMBus client will acknowledge all data bytes that it receives (as well as the client address if it matches and the ARA address if the ALERT# pin is asserted). This is done by the client device pulling the SMBus Data line low after the 8th bit of each byte that is transmitted. The Host will NACK (not acknowledge) the data received from the client by holding the SMBus data line high after the 8th data bit has been sent. Revision 1.1 (10-12-09) 12 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet 3.1.5 SMBus Stop Bit The SMBus Stop bit is defined as a transition of the SMBus Data line from a logic ‘0’ state to a logic ‘1’ state while the SMBus clock line is in a logic ‘1’ state. When the EMC2301 detects an SMBus Stop bit has been communicating with the SMBus protocol, it will reset its client interface and prepare to receive further communications. 3.1.6 SMBus Time-out The EMC2301 includes an SMBus timeout feature. Following a 30ms period of inactivity on the SMBus, the device will time-out and reset the SMBus interface. The SMBus timeout feature is disabled by default and can be enabled via clearing the DIS_TO bit in the Configuration register (20h). 3.1.7 SMBus and I2C Compliance The major difference between SMBus and I2C devices is highlighted here. For complete compliance information refer to the SMBus 2.0 specification. 1. Minimum frequency for SMBus communications is 10kHz (I2C has no minimum frequency). 2. The slave protocol will reset if the clock is held low for longer than 30ms (I2C has no timeout). 3. The slave protocol will reset if both the clock and data lines are held high for longer than 150us. 4. I2C devices do not support the Alert Response Address functionality (which is optional for SMBus). 5. The Block Read and Block Write protocols are only compliant with I2C data formatting. They do not support SMBus formatting for Block Read and Block Write protocols. 3.2 SMBus Protocols The EMC2301 is SMBus 2.0 compatible and supports Send Byte, Read Byte, Receive Byte and Write Byte as valid protocols as shown below. It will respond to the Alert Response Address protocol but is not in full compliance. All of the below protocols use the convention in Table 3.1. When reading the protocol blocks, the value of YYYY_YYYb should be replaced with the respective SMBus addresses. Table 3.1 Protocol Format DATA SENT TO DEVICE # of bits sent 3.2.1 DATA SENT TO THE HOST # of bits sent Write Byte The Write Byte is used to write one byte of data to the registers as shown below Table 3.2. Table 3.2 Write Byte Protocol START SLAVE ADDRESS WR ACK REGISTER ADDRESS ACK REGISTER DATA ACK STOP 1 -> 0 YYYY_YYYb 0 0 XXh 0 XXh 0 0 -> 1 SMSC EMC2301 13 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet 3.2.2 Read Byte The Read Byte protocol is used to read one byte of data from the registers as shown in Table 3.3. Table 3.3 Read Byte Protocol START SLAVE ADDRESS WR ACK Register Address ACK START Slave Address RD ACK Register Data NACK STOP 1 -> 0 YYYY_YYYb 0 0 XXh 0 0 -> 1 YYYY_YYYb 1 0 XXh 1 0 -> 1 3.2.3 Send Byte The Send Byte protocol is used to set the internal address register pointer to the correct address location. No data is transferred during the Send Byte protocol as shown in Table 3.4. Table 3.4 Send Byte Protocol START SLAVE ADDRESS WR ACK REGISTER ADDRESS ACK STOP 1 -> 0 YYYY_YYYb 0 0 XXh 0 0 -> 1 3.2.4 Receive Byte The Receive Byte protocol is used to read data from a register when the internal register address pointer is known to be at the right location (e.g. set via Send Byte). This is used for consecutive reads of the same register as shown in Table 3.5. Table 3.5 Receive Byte Protocol START SLAVE ADDRESS RD ACK REGISTER DATA NACK STOP 1 -> 0 YYYY_YYYb 1 0 XXh 1 0 -> 1 3.2.5 Block Write Protocol The Block Write is used to write multiple data bytes to a group of contiguous registers as shown in Table 3.6. It is an extension of the Write Byte Protocol. Table 3.6 Block Write Protocol START SLAVE ADDRESS WR ACK REGISTER ADDRESS ACK REGISTER DATA ACK 1 ->0 YYYY_YYYb 0 0 XXh 0 XXh 0 REGISTER DATA ACK REGISTER DATA ACK ... REGISTER DATA ACK STOP XXh 0 XXh 0 ... XXh 0 0 -> 1 Revision 1.1 (10-12-09) 14 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet 3.2.6 Block Read Protocol The Block Read is used to read multiple data bytes from a group of contiguous registers as shown in Table 3.7. It is an extension of the Read Byte Protocol. Table 3.7 Block Read Protocol START SLAVE ADDRESS WR ACK REGISTER ADDRESS ACK START SLAVE ADDRESS RD ACK REGISTER DATA 1->0 YYYY_YYYb 0 0 XXh 0 1 ->0 YYYY_YYYb 1 0 XXh ACK REGISTER DATA ACK REGISTER DATA ACK REGISTER DATA ACK ... REGISTER DATA NACK STOP 0 XXh 0 XXh 0 XXh 0 ... XXh 1 0 -> 1 3.2.7 Alert Response Address The ALERT# output can be used as a processor interrupt or as an SMBus Alert when configured to operate as an interrupt. When it detects that the ALERT# pin is asserted, the host will send the Alert Response Address (ARA) to the general address of 0001_100xb. All devices with active interrupts will respond with their client address as shown in Table 3.8. Table 3.8 Alert Response Address Protocol START ALERT RESPONSE ADDRESS RD ACK DEVICE ADDRESS NACK STOP 1 -> 0 0001_100b 1 0 YYYY_YYYb 1 0 -> 1 The EMC2301 will respond to the ARA in the following way if the ALERT# pin is asserted. 1. Send Slave Address and verify that full slave address was sent (i.e. the SMBus communication from the device was not prematurely stopped due to a bus contention event). 2. Set the MASK bit to clear the ALERT# pin. SMSC EMC2301 15 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet Chapter 4 Product Description The EMC2301 is an SMBus compliant fan controller with a programmable frequency PWM fan driver. The fan driver can be operated using two modes: the RPM-based Fan Speed Control Algorithm or the direct fan drive setting. Figure 4.1 shows a system diagram of the EMC2301. 3.3V VDD MCU tachometer TACH SMCLK Drive Circuit SMDATA PWM ALERT# 32.768KHz Clock Input or Output GND CLK EMC2301 Figure 4.1 System Diagram of EMC2301 4.1 Fan Control Modes of Operation The EMC2301 has two modes of operation for the fan driver. Each mode of operation uses the Ramp Rate control and Spin Up Routine. 1. Direct Setting Mode - in this mode of operation, the user directly controls the fan drive setting. Updating the Fan Driver Setting Register (see Section 5.7) will instantly update the PWM fan drive. Ramp Rate control is optional and enabled via the EN_RRC bits. Whenever the Direct Setting Mode is enabled, the current drive will be changed to what was last written into the Fan Driver Setting Register. 2. Fan Speed Control Mode (FSC) - in this mode of operation, the user determines a target tachometer count and the PWM drive setting is automatically updated to achieve this target speed. The algorithm uses the Spin Up Routine and has user definable ramp rate controls. This mode is enabled setting the EN_ALGO bit in the Fan Configuration Register. Table 4.1 Fan Controls Active for Operating Mode DIRECT SETTING MODE FSC MODE Fan Driver Setting (read / write) Fan Driver Setting (read only) EDGES[1:0] EDGES[1:0] (Fan Configuration) Revision 1.1 (10-12-09) 16 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet Table 4.1 Fan Controls Active for Operating Mode (continued) DIRECT SETTING MODE FSC MODE - RANGE[1:0] (Fan Configuration) UPDATE[2:0] (Fan Configuration) UPDATE[2:0] (Fan Configuration) LEVEL (Spin Up Configuration) LEVEL (Spin Up Configuration) SPINUP_TIME[1:0] (Spin Up Configuration) SPINUP_TIME[1:0] (Spin Up Configuration) Fan Step Fan Step - Fan Minimum Drive Valid TACH Count Valid TACH Count - TACH Target (read / write) TACH Reading TACH Reading - DRIVE_FAIL_CNT[1:0] and Drive Band Fail Registers 4.2 PWM Fan Driver The EMC2301 supports a PWM output driver. The output driver can be configured to operate as an open-drain (default) or push-pull driver and the driver can be configured with normal or inverse polarity. Additionally, the PWM frequencies is programmable with ranges from 9.5Hz to 26kHz in four programmable frequency bands. 4.3 RPM-based Fan Speed Control Algorithm (FSC) The EMC2301 includes an RPM-based Fan Speed Control Algorithm. The algorithm is controlled manually (by setting the target fan speed). This fan control algorithm uses Proportional, Integral, and Derivative terms to automatically approach and maintain the system’s desired fan speed to an accuracy directly proportional to the accuracy of the clock source. The desired tachometer count is set by the user inputting the desired number of 32.768kHz cycles that occur per fan revolution. This is done by manually setting the TACH Target Register. The user may change the target count at any time. The user may also set the target count to FFh in order to disable the fan driver for lower current operation. For example, if a desired RPM rate for a 2-pole fan is 3000 RPMs, then the user would input the hexidecimal equivalent of 1296 (51h in the TACH Target Register). This number represents the number of 32.768KHz cycles that would occur during the time it takes the fan to complete a single revolution when it is spinning at 3000RPMs. The EMC2301’s RPM-based Fan Speed Control Algorithm has programmable configuration settings for parameters such as ramp-rate control and spin up conditions. The fan driver automatically detects and attempts to alleviate a stalled/stuck fan condition while also asserting the ALERT# pin. The EMC2301 works with fans that operate up to 16,000 RPMs and provide a valid tachometer signal. The fan controller will function either with an externally supplied 32.768kHz clock source or with it’s own internal 32kHz oscillator depending on the required accuracy. The EMC2301 offers a clock output that enables additional devices to be slaved to the same clock source. SMSC EMC2301 17 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet 4.3.1 Programming the RPM-based Fan Speed Control Algorithm The RPM-based Fan Speed Control Algorithm is disabled upon device power up. The following registers control the algorithm. The EMC2301 fan control registers are pre-loaded with defaults that will work for a wide variety of fans so only the TACH Target Register is required to set a fan speed. The other fan control registers can be used to fine-tune the algorithm behavior based on application requirements. Note that steps 1 - 6 are optional and need only be performed if the default settings do not provide the desired fan response. 1. Set the Spin Up Configuration Register to the Spin Up Level and Spin Time desired. 2. Set the Fan Step Register to the desired step size. 3. Set the Fan Minimum Drive Register to the minimum drive value that will maintain fan operation. 4. Set the Update Time and Edges options in the Fan Configuration Register. 5. Set the Valid TACH Count Register to the highest tach count that indicates the fan is spinning. Refer to AN17.4 RPM to TACH Counts Conversion for examples and tables for supported RPM ranges (500, 1k, 2k, 4k). 6. Set the TACH Target Register to the desired tachometer count. 7. Enable the RPM-based Fan Speed Control Algorithm by setting the EN_ALGO bit. 4.4 Tachometer Measurement The tachometer measurement circuitry is used in conjunction with the RPM-based Fan Speed Control Algorithm to update the fan driver output. Additionally, it can be used in Direct Setting mode as a diagnostic for host based fan control. This method monitors the TACHx signal in real time. It constantly updates the tachometer measurement by reporting the number of clocks between a user programmed number of edges on the TACHx signal (see Table 5.12). The tachometer measurement provides fast response times for the RPM-based Fan Speed Control Algorithm and the data is presented as a count value that represents the fan RPM period. APPLICATION NOTE: The tachometer measurement method works independently of the drive settings. If the device is put into Direct Setting and the fan drive is set at a level that is lower than the fan can operate (including zero drive), then the tachometer measurement may signal a Stalled Fan condition and assert an interrupt. 4.4.1 Stalled Fan A Stalled fan is detected if the tach counter exceeds the user-programmable Valid TACH Count setting. If a stall is detected, the device will flag the fan as stalled and trigger an interrupt. If the RPM-based Fan Speed Control Algorithm is enabled, the algorithm will automatically attempt to restart the fan until it detects a valid tachometer level or is disabled. The FAN_STALL Status bit indicates that a stalled fan was detected. This bit is checked conditionally depending on the mode of operation. Whenever the Direct Setting Mode or the Spin Up Routine is enabled, the FAN_STALL interrupt will be masked for the duration of the programmed Spin Up Time (see Table 5.22) to allow the fan to reach a valid speed without generating unnecessary interrupts. In Direct Setting Mode, whenever the TACH Reading Register value exceeds the Valid TACH Count Register setting, the FAN_STALL status bit will be set. When using the RPM-based Fan Speed Control Algorithm, the stalled fan condition is checked whenever the Update Time is met and the fan drive setting is updated. It is not a continuous check. Revision 1.1 (10-12-09) 18 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet 4.4.2 Aging Fan or Invalid Drive Detection This is useful to detect aging fan conditions (where the fan’s natural maximum speed degrades over time) or a speed setting that is faster than the fan is capable of. The EMC2301 contains circuitry that detects that the programmed fan speed can be reached by the fan. If the target fan speed cannot be reached within a user defined band of tach counts at maximum drive, the DRIVE_FAIL status bits are set and the ALERT# pin is asserted. 4.5 CLK Pin The CLK pin has multiple functionality as determined by the settings of the Configuration register. 4.5.1 External Clock The EMC2301 allows the user to choose between supplying an external 32.768kHz clock or use of the internal 32kHz oscillator to measure the tachometer signal. This clock source is used by the RPMbased Fan Speed Control Algorithm to calculate the current fan speed. This fan controller accuracy is directly proportional to the accuracy of the clock source. When this function is used, the external clock is driven into the device via the CLK pin. 4.5.2 Internal Clock Alternately, the EMC2301 may be configured to use its internal clock as a clock output to drive other fan driver devices. When configured to operate in this mode, the device uses its internal clock for tachometer reading and drives the CLK pin using a push-pull driver. 4.6 Spin Up Routine The EMC2301 also contains programmable circuitry to control the spin up behavior of the fan driver to ensure proper fan operation. The Spin Up Routine is initiated in Direct Setting mode when the setting value changes from 00h to anything else. When the Fan Speed Control Algorithm is enabled, the Spin Up Routine is initiated under the following conditions: 1. The TACH Target Register value changes from a value of FFh to a value that is less than the Valid TACH Count (see Section 5.15). 2. The RPM-based Fan Speed Control Algorithm’s measured TACH Reading Register value is greater than the Valid TACH Count setting. When the Spin Up Routine is operating, the fan driver is set to full scale (optional) for one quarter of the total user defined spin up time. For the remaining spin up time, the fan driver output is set at a user defined level (30% through 65% drive). After the Spin Up Routine has finished, the EMC2301 measures the TACHx signal. If the measured TACH Reading Register value is higher than the Valid TACH Count Register setting, the FAN_SPIN status bit is set and the Spin Up Routine will automatically attempt to restart the fan. Figure 4.2 shows an example of the Spin Up Routine in response to a programmed fan speed change based on the first condition above. SMSC EMC2301 19 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet 100% (optional) 30% through 65% Fan Step New Target Count Algorithm controlled drive Prev Target Count = FFh ¼ of Spin Up Time Update Time Spin Up Time Check TACH Target Count Changed Target Count Reached Figure 4.2 Spin Up Routine 4.7 Ramp Rate Control The Fan Driver can be configured with automatic ramp rate control. Ramp rate control is accomplished by adjusting the drive output settings based on the Maximum Fan Step Register settings and the Update Time settings. If the RPM-based Fan Speed Control Algorithm is used, then this ramp rate control is automatically used. The user programs a maximum step size for the fan drive setting and an update time. The update time varies from 100ms to 1.6s while the fan drive maximum step can vary from 1 count to 31 counts. When a new fan drive setting is entered, the delta from the next fan drive setting and the previous fan drive setting is determined. If this delta is greater than the Max Step settings, then the fan drive setting is incrementally adjusted every 100ms to 1.6s as determined by the Update Time until the target fan drive setting is reached. See Figure 4.3. Revision 1.1 (10-12-09) 20 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet Next Desired Setting Max Step Max Step Previous Setting Update Time Update Time Setting Changed Figure 4.3 Ramp Rate Control 4.8 Watchdog Timer The EMC2301 contains an internal Watchdog Timer for the fan driver. The Watchdog timer monitors the SMBus traffic for signs of activity and works in two different modes based upon device operation. These modes are Power Up Operation and Continuous Operation as described below. For either mode of operation, if four (4) seconds elapse without activity detected by the host, then the watchdog will be triggered and the following will occur: 1. The WATCH status bit will be set. 2. The fan driver will be set to full scale drive. It will remain at full scale drive until it is disabled. APPLICATION NOTE: When the Watchdog timer is activated, the Fan Speed Control Algorithm is automatically disabled. Disabling the Watchdog will not automatically set the fan drive nor re-activate the Fan Speed Control Algorithm. This must be done manually. 4.8.1 Power Up Operation The Watchdog Timer only starts immediately after power-up. Once it has been triggered or deactivated, it will not restart although it can be configured to operate in Continuous operation. While the Watchdog timer is active, the device will not check for a Stalled Fan condition. In the Power Up Operation, the Watchdog Timer is disabled by any of the following actions: 1. Writing the Fan Setting Register will disable the Watchdog Timer. 2. Enabling the RPM-based Fan Speed Control Algorithm by setting the EN_ALGO bit will disable the Watchdog Timer. The fan driver will be set based on the RPM-based Fan Speed Control Algorithm. Writing any other configuration registers will not disable the Watchdog Timer upon power up. SMSC EMC2301 21 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet 4.8.2 Continuous Operation When configured to operate in Continuous Operation, the Watchdog timer will start immediately. The timer will be reset by any access (read or write) to the SMBus register set. The four second Watchdog timer will restart upon completion of SMBus activity. Revision 1.1 (10-12-09) 22 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet Chapter 5 Register Set 5.1 Register Map The following registers are accessible through the SMBus Interface. All register bits marked as ‘-’ will always read ‘0’. A write to these bits will have no effect. Table 5.1 EMC2301 Register Set ADDR R/W REGISTER NAME FUNCTION DEFAULT VALUE LOCK PAGE Configuration and control 20h R/W Configuration Configures the clocking and watchdog functionality 40h SWL Page 25 24h R-C Fan Status Stores the status bits for the RPMbased Fan Speed Control Algorithm 00h No Page 25 25h R-C Fan Stall Status Stores status bits associated with a stalled fan 00h No Page 25 26h R-C Fan Spin Status Stores status bits associated with a spin-up failure 00h No Page 25 27h R-C Drive Fail Status Stores status bits associated with drive failure 00h No Page 25 29h R/W Fan Interrupt Enable Register Controls the masking of interrupts on all fan related channels 00h No Page 27 2Ah R/W PWM Polarity Config Configures Polarity of the PWM driver 00h No Page 27 2Bh R/W PWM Output Config Configures Output type of the PWM driver 00h No Page 27 2Dh R/W PWM Base Frequency Selects the base frequency for the PWM output 00h No Page 28 00h No Page 28 Fan Control Registers 30h R/W Fan Setting Always displays the most recent fan driver input setting for the Fan. If the RPM-based Fan Speed Control Algorithm is disabled, allows direct user control of the fan driver. 31h R/W PWM Divide Stores the divide ratio to set the frequency for the Fan 01h No Page 29 32h R/W Fan Configuration 1 Sets configuration values for the RPMbased Fan Speed Control Algorithm for the Fan driver 2Bh No Page 29 33h R/W Fan Configuration 2 Sets additional configuration values for the Fan driver 28h SWL Page 30 35h R/W Gain Holds the gain terms used by the RPMbased Fan Speed Control Algorithm for the Fan driver 2Ah SWL Page 32 SMSC EMC2301 23 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet Table 5.1 EMC2301 Register Set (continued) REGISTER NAME FUNCTION DEFAULT VALUE LOCK PAGE R/W Fan Spin Up Configuration Sets the configuration values for Spin Up Routine of the Fan driver 19h SWL Page 32 37h R/W Fan Max Step Sets the maximum change per update for the Fan driver 10h SWL Page 34 38h R/W Fan Minimum Drive Sets the minimum drive value for the Fan driver 66h (40%) SWL Page 34 39h R/W Fan Valid TACH Count Holds the tachometer reading that indicates Fan is spinning properly F5h SWL Page 35 3Ah R/W Fan Drive Fail Band Low Byte 00h SWL 3Bh R/W Fan Drive Fail Band High Byte Stores the number of Tach counts used to determine how the actual fan speed must match the target fan speed at full scale drive 00h SWL 3Ch R/W TACH Target Low Byte Holds the target tachometer reading low byte for the Fan F8h No Page 36 3Dh R/W TACH Target High Byte Holds the target tachometer reading high byte for the Fan FFh No Page 36 3Eh R TACH Reading High Byte Holds the tachometer reading high byte for the Fan FFh No Page 36 3Fh R TACH Reading Low Byte Holds the tachometer reading low byte for the Fan F8h No Page 36 00h SWL Page 37 ADDR R/W 36h Page 35 Lock Register EF R/W Software Lock Locks all SWL registers Revision Registers FDh R Product ID Stores the unique Product ID 37h No Page 37 FEh R Manufacturer ID Stores the Manufacturer ID 5Dh No Page 38 FFh R Revision Revision 80h No Page 38 During Power-On-Reset (POR), the default values are stored in the registers. A POR is initiated when power is first applied to the part and the voltage on the VDD supply surpasses the POR level as specified in the electrical characteristics. Any reads to undefined registers will return 00h. Writes to undefined registers will not have an effect. 5.1.1 Lock Entries The Lock Column describes the locking mechanism, if any, used for individual registers. All SWL registers are Software Locked and therefore made read-only when the LOCK bit is set. Revision 1.1 (10-12-09) 24 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet 5.2 Configuration Register Table 5.2 Configuration Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 20h R/W Configuration MASK DIS_TO WD_EN - - - DR_EXT_ CLK USE_ EXT_ CLK 40h The Configuration Register controls the basic functionality of the EMC2301. The bits are described below. The Configuration Register is software locked. Bit 7 - MASK - Blocks the ALERT# pin from being asserted. ‘0’ (default) - The ALERT# pin is unmasked. If any bit in either status register is set, the ALERT# pins will be asserted (unless individually masked via the Mask Register). ‘1’ - The ALERT# pin is masked and will not be asserted. Bit 6 - DIS_TO - Disables the SMBus timeout function for the SMBus client (if enabled). ‘0’ - The SMBus timeout function is enabled. ‘1’ (default) - The SMBus timeout function is disabled allowing the device to be fully I2C compliant. Bit 5 - WD_EN - Enables the Watchdog timer to operate in Continuous Mode (see Section 4.8.2). ‘0’ (default) - The Watchdog timer does not operate continuously. It will function upon power up and at no other time. ‘1’ - The Watchdog timer operates continuously as described in Section 4.8. Bit 1 - DR_EXT_CLK - Enables the internal tachometer clock to be driven out on the CLK pin so that multiple devices can be synced to the same source. ‘0’ (default) - The CLK pin acts as a clock input. ‘1’ - The CLK pin acts as a clock output and is a push-pull driver. Bit 0 - USE_EXT_CLK - Enables the EMC2301 to use a clock present on the CLK pin as the tachometer clock. If the DR_EXT_CLK bit is set, then this bit is ignored and the device will use the internal oscillator. 5.3 ‘0’ (default) - The EMC2301 will use its internal oscillator for all Tachometer measurements. ‘1’ - The EMC2301 will use the oscillator presented on the CLK pin for all Tachometer measurements. Fan Status Registers Table 5.3 Fan Status Registers ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 24h R-C Fan Status WATCH - - - - DRIVE_ FAIL FAN_ SPIN FAN_ STALL 00h 25h R-C Fan Stall Status - - - - - - - FAN_ STALL 00h SMSC EMC2301 25 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet Table 5.3 Fan Status Registers (continued) ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 26h R-C Fan Spin Status - - - - - - - FAN_ SPIN 00h 27h R-C Fan Drive Fail Status - - - - - - DRIVE_ FAIL 00h - The Fan Status registers contain the status bits associated with the fan driver. 5.3.1 Fan Status - 24h The Fan Status register indicates that the fan driver has stalled or failed or that the Watchdog Timer has expired (see Section 4.8). Bit 7 - WATCH - Indicates that the Watchdog Timer has expired. When set, the fan is driven to 100% duty cycle and will remain at 100% duty cycle until it is programmed. This bit is cleared when it is read. Bit 2 - DRIVE_FAIL - Indicates that the fan driver cannot meet the programmed fan speed at maximum PWM duty cycle. This bit is set when the DRIVE_FAIL bit is set (in the Fan Drive Fail Status register). This bit is cleared when the DRIVE_FAIL bit is cleared. Bit 1 - FAN_SPIN - Indicates that the fan driver cannot spin up. This bit is set when the FAN_SPIN bit is set (in the Fan Spin Status register). This bit is cleared when the FAN_SPIN bit is cleared. Bit 0 - FAN_STALL - Indicates that the fan driver have stalled. This bit is set when the FAN_STALL bit is set (in the Fan Stall Status register). This bit is cleared when the FAN_STALL bit is cleared. 5.3.2 Fan Stall Status - 25h The Fan Stall Status register indicates that the fan driver has detected a stalled condition (see Section 4.4.1). This bit is cleared upon a read if the error condition has been removed. Bit 0 - FAN_STALL - Indicates that the Fan has stalled. 5.3.3 Fan Spin Status - 26h The Fan Spin Status register indicates that the fan driver has failed to spin-up (see Section 4.6). This bit is cleared upon a read if the error condition has been removed. Bit 0 - FAN_SPIN - Indicates that the Fan has failed to spin up. 5.3.4 Fan Drive Fail Status - 27h The Fan Drive Fail Status register indicates that the fan driver cannot drive to the programmed speed even at 100% duty cycle (see Section 4.4.2 and Section 5.12). This bit is cleared upon a read if the error condition has been removed. Bit 0 - DRIVE_FAIL1 - Indicates that the Fan cannot reach its programmed fan speed even at 100% duty cycle. This may be due to an aging fan or invalid programming. Revision 1.1 (10-12-09) 26 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet 5.4 Fan Interrupt Enable Register Table 5.4 Fan Interrupt Enable Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 29h R/W Fan Interrupt Enable - - - - - - - FAN_ INT_EN 00h The Fan Interrupt Enable controls the masking for the Fan channel. When a channel is enabled, it will cause the ALERT# pin to be asserted when an error condition is detected. Bit 0 - FAN_INT_EN - Allows the Fan to assert the ALERT# pin if an error condition is detected. 5.5 ‘0’ (default) - An error condition on Fanwill not cause the ALERT# pin to be asserted, however the status registers will be updated normally. ‘1’ - An error condition (Stall, Spin Up, Drive Fail) on the Fan will cause the ALERT# pin to be asserted. PWM Configuration Registers Table 5.5 PWM Configuration Registers ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 2Ah R/W PWM Polarity Config - - - - - - - POLARITY 00h 2Bh R/W PWM Output Config - - - - - - - PWM_OT 00h The PWM Config registers control the output type and polarity of all PWM outputs. 5.5.1 PWM Polarity Config - 2Ah Bit 0 - POLARITY - Determines the polarity of the PWM. 5.5.2 ‘0’ (default) - the Polarity of the PWM driver is normal. A drive setting of 00h will cause the output to be set at 0% duty cycle and a drive setting of FFh will cause the output to be set at 100% duty cycle. ‘1’ - The Polarity of the PWM driver is inverted. A drive setting of 00h will cause the output to be set at 100% duty cycle and a drive setting of FFh will cause the output to be set at 0% duty cycle. PWM Output Config - 2Bh Bit 0 - PWM_OT - Determines the output type of the PWM driver. ‘0’ (default) - The PWM output is configured as an open drain output. ‘1’ - The PWM output is configured as a push-pull output. SMSC EMC2301 27 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet 5.6 PWM Base Frequency Register Table 5.6 PWM Base Frequency Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 2Dh R/W PWM Base Frequency - - - - - - PWM_ BASE _1 PWM_ BASE _0 00h The PWM Base Frequency register determines the base frequency that is used with the PWM Divide register to determine the final PWM frequency. The PWM frequency is set by the base frequency and its respective divide ratio (see Section 5.8). Controls the base frequency of the PWM driver Bits 1-0 - PWM_BASE1[1:0] - Determines the base frequency of the PWM driver. Table 5.7 PWM_BASEx[1:0] Bit Decode PWM_BASEX[1:0] 5.7 1 0 BASE FREQUENCY 0 0 26.00kHz (default) 0 1 19.531kHz 1 0 4,882Hz 1 1 2,441Hz Fan Setting Register Table 5.8 Fan Driver Setting Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 30h R/W Fan Setting 128 64 32 16 8 4 2 1 00h The Fan Setting register always displays the current setting of the fan driver. Reading from the register will report the current fan speed setting of the fan driver regardless of the operating mode. Therefore it is possible that reading from this register will not report data that was previously written into this register. While the RPM-based Fan Speed Control Algorithm is active, the register is read only. Writing to the register will have no effect and the data will not be stored. The contents of the register represent the weighting of each bit in determining the final output voltage. The output drive for a PWM output is given by Equation [1]. VALUE Drive = ⎛⎝ ---------------------⎞⎠ × 100% 255 Revision 1.1 (10-12-09) 28 DATASHEET [1] SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet 5.8 PWM Divide Register Table 5.9 PWM Divide Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 31h R/W Fan Divide 128 64 32 16 8 4 2 1 01h The PWM Divide registers determine the final frequency of the PWM Fan Driver. The driver base frequency is divided by the value of the PWM Divide Register to determine the final frequency. The duty cycle settings are not affected by these settings, only the final frequency of the PWM driver. A value of 00h will be decoded as 01h. 5.9 Fan Configuration 1 Register Table 5.10 Fan Configuration 1 Register ADDR R/W REGISTER B7 B6 32h R/W Fan Configuration 1 EN_ ALGO B5 B4 RANGE[1:0] B3 B2 EDGES[1:0] B1 B0 UPDATE[2:0] DEFAULT 2Bh The Fan Configuration 1 register controls the general operation of the RPM-based Fan Speed Control Algorithm used for the Fan Driver. Bit 7 - EN_ALGO - enables the RPM-based Fan Speed Control Algorithm. ‘0’ - (default) the control circuitry is disabled and the fan driver output is determined by the Fan Driver Setting Register. ‘1’ - the control circuitry is enabled and the Fan Driver output will be automatically updated to maintain the programmed fan speed as indicated by the TACH Target Register. Bits 6- 5 - RANGE[1:0] - Adjusts the range of reported and programmed tachometer reading values. The RANGE bits determine the weighting of all TACH values (including the Valid TACH Count, TACH Target, and TACH reading) as shown in Table 5.11. Table 5.11 Range Decode RANGE[1:0] 1 0 REPORTED MINIMUM RPM TACH COUNT MULTIPLIER 0 0 500 1 0 1 1000 (default) 2 1 0 2000 4 1 1 4000 8 Bits 4-3 - EDGES[1:0] - determines the minimum number of edges that must be detected on the TACHx signal to determine a single rotation. A typical fan measured 5 edges (for a 2-pole fan). For more accurate tachometer measurement, the minimum number of edges measured may be increased. Increasing the number of edges measured with respect to the number of poles of the fan will cause the TACH Reading registers to indicate a fan speed that is higher or lower than the actual speed. In SMSC EMC2301 29 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet order for the FSC Algorithm to operate correctly, the TACH Target must be updated by the user to accommodate this shift. The Effective Tach Multiplier shown in Table 5.12 is used as a direct multiplier term that is applied to the Actual RPM to achieve the Reported RPM. It should only be applied if the number of edges measured does not match the number of edges expected based on the number of poles of the fan (which is fixed for any given fan). Contact SMSC for recommended settings when using fans with more or less than 2 poles. Table 5.12 Minimum Edges for Fan Rotation EDGES[1:0] 1 0 MINIMUM TACH EDGES NUMBER OF FAN POLES EFFECTIVE TACH MULTIPLIER (BASED ON 2 POLE FANS) 0 0 3 1 pole 0.5 0 1 5 2 poles (default) 1 0 7 3 poles 1.5 1 1 9 4 poles 2 1 Bit 2-0 - UPDATE[2:0] - determines the base time between fan driver updates. The Update Time, along with the Fan Step Register, is used to control the ramp rate of the drive response to provide a cleaner transition of the actual fan operation as the desired fan speed changes. The Update Time is set as shown in Table 5.13. Table 5.13 Update Time UPDATE[2:0] 5.10 2 1 0 UPDATE TIME 0 0 0 100ms 0 0 1 200ms 0 1 0 300ms 0 1 1 400ms (default) 1 0 0 500ms 1 0 1 800ms 1 1 0 1200ms 1 1 1 1600ms Fan Configuration 2 Register Table 5.14 Fan Configuration 2 Register ADDR R/W REGISTER B7 B6 B5 33h R/W Fan Configuration 2 - EN_ RRC GLITCH_ EN Revision 1.1 (10-12-09) B4 B3 DER_OPT [1:0] 30 DATASHEET B2 B1 ERR_RNG[1:0] B0 DEFAULT - 28h SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet The Fan Configuration 2 register controls the tachometer measurement and advanced features of the RPM-based Fan Speed Control Algorithm. Bit 6 - EN_RRC - Enables ramp rate control when the fan driver is operated in the Direct Setting Mode. ‘0’ (default) - Ramp rate control is disabled. When the fan driver is operating in Direct Setting mode, the fan setting will instantly transition to the next programmed setting. ‘1’ - Ramp rate control is enabled. When the fan driver is operating in Direct Setting mode, the fan drive setting will follow the ramp rate controls as determined by the Fan Step and Update Time settings. The maximum fan drive setting step is capped at the Fan Step setting and is updated based on the Update Time as given by Table 5.13. Bit 5 - GLITCH_EN - Disables the low pass glitch filter that removes high frequency noise injected on the TACHx pin. ‘0’ - The glitch filter is disabled. ‘1’ (default) - The glitch filter is enabled. Bits 4 - 3 - DER_OPT[1:0] - Control some of the advanced options that affect the derivative portion of the RPM-based Fan Speed Control Algorithm as shown in Table 5.15. Table 5.15 Derivative Options DER_OPT[1:0] 1 0 OPERATION 0 0 No derivative options used 0 1 Basic derivative. The derivative of the error from the current drive setting and the target is added to the iterative Fan Drive Register setting (in addition to proportional and integral terms) (default) 1 0 Step derivative. The derivative of the error from the current drive setting and the target is added to the iterative Fan Drive Register setting and is not capped by the Fan Step Register. 1 1 Both the basic derivative and the step derivative are used effectively causing the derivative term to have double the effect of the derivative term. Bit 2 - 1 - ERR_RNG[1:0] - Control some of the advanced options that affect the error window. When the measured fan speed is within the programmed error window around the target speed, then the fan drive setting is not updated. The algorithm will continue to monitor the fan speed and calculate necessary drive setting changes based on the error; however, these changes are ignored. Table 5.16 Error Range Options ERR_RNG[1:0] 1 0 OPERATION 0 0 0 RPM (default) 0 1 50 RPM 1 0 100 RPM SMSC EMC2301 31 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet Table 5.16 Error Range Options (continued) ERR_RNG[1:0] 5.11 1 0 OPERATION 1 1 200 RPM Gain Register Table 5.17 Gain Register ADDR R/W REGISTER B7 B6 35h R/W Gain Register - - B5 B4 B3 GAIND[1:0] B2 B1 GAINI[1:0] B0 DEFAULT GAINP[1:0] 2Ah The Gain register stores the gain terms used by the proportional and integral portions of the RPMbased Fan Speed Control Algorithm. These gain terms are used as the KD, KI, and KP gain terms in a classic PID control solution. Bits 5 - 4 - GAINDX[1:0] - Controls the derivative gain term used by the FSC algorithm as shown in Table 5.18. Bits 3-2 - GAINIX[1:0] - Controls the integral gain term used by the FSC algorithm as shown in Table 5.18. Bits 1-0 - GAINP[1:0] - Controls the proportional gain term used by the FSC algorithm as shown in Table 5.18. Table 5.18 Gain Decode GAIND OR GAINP OR GAINI [1:0] 5.12 1 0 RESPECTIVE GAIN FACTOR 0 0 1x 0 1 2x 1 0 4x (default) 1 1 8x Fan Spin Up Configuration Register Table 5.19 Fan Spin Up Configuration Register ADDR R/W REGISTER 36h R/W Fan Spin Up Configuration B7 B6 DRIVE_FAIL_ CNT [1:0] B5 NOKICK B4 B3 B2 SPIN_LVL[2:0] B1 B0 SPINUP_TIME [1:0] DEFAULT 19h The Fan Spin Up Configuration register controls the settings of Spin Up Routine. The Fan Spin Up Configuration register is software locked. Revision 1.1 (10-12-09) 32 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet Bit 7 - 6 - DRIVE_FAIL_CNT[1:0] - Determines how many update cycles are used for the Drive Fail detection function as shown in Table 5.20. This circuitry determines whether the fan can be driven to the desired tach target. Table 5.20 DRIVE_FAIL_CNT[1:0] Bit Decode DRIVE_FAIL_CNT[1:0] 1 0 NUMBER OF UPDATE PERIODS 0 0 Disabled - the Drive Fail detection circuitry is disabled (default) 0 1 16 - the Drive Fail detection circuitry will count for 16 update periods 1 0 32 - the Drive Fail detection circuitry will count for 32 update periods 1 1 64 - the Drive Fail detection circuitry will count for 64 update periods Bit 5 - NOKICK - Determines if the Spin Up Routine will drive the fan to 100% duty cycle for 1/4 of the programmed spin up time before driving it at the programmed level. ‘0’ (default) - The Spin Up Routine will drive the fan driver to 100% for 1/4 of the programmed spin up time before reverting to the programmed spin level. ‘1’ - The Spin Up Routine will not drive the fan driver to 100%. It will set the drive at the programmed spin level for the entire duration of the programmed spin up time. Bits 4 - 2 - SPIN_LVL[2:0] - Determines the final drive level that is used by the Spin Up Routine as shown in Table 5.21. Table 5.21 Spin Level SPIN_LVL[2:0] 2 1 0 SPIN UP DRIVE LEVEL 0 0 0 30% 0 0 1 35% 0 1 0 40% 0 1 1 45% 1 0 0 50% 1 0 1 55% 1 1 0 60% (default) 1 1 1 65% Bit 1 -0 - SPINUP_TIME[1:0] - determines the maximum Spin Time that the Spin Up Routine will run for (see Section 4.6). If a valid tachometer measurement is not detected before the Spin Time has elapsed, then an interrupt will be generated. When the RPM-based Fan Speed Control Algorithm is active, the fan driver will attempt to re-start the fan immediately after the end of the last spin up attempt. The Spin Time is set as shown in Table 5.22. SMSC EMC2301 33 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet Table 5.22 Spin Time SPINUP_TIME[1:0] 5.13 1 0 TOTAL SPIN UP TIME 0 0 250 ms 0 1 500 ms (default) 1 0 1 sec 1 1 2 sec Fan Max Step Register Table 5.23 Fan Max Step Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 37h R/W Fan Max Step - - 32 16 8 4 2 1 10h The Fan Max Step register, along with the Update Time, controls the ramp rate of the fan driver response calculated by the RPM-based Fan Speed Control Algorithm. The value of the register represents the maximum step size the fan driver will take between update times (see Section 5.9). When the FSC algorithm is enabled, Ramp Rate control is automatically used. When the FSC is not active, then Ramp Rate control can be enabled by asserting the EN_RRC bit (see Section 5.10). APPLICATION NOTE: The UPDATE bits and Fan Step Register settings operate independently of the RPM-based Fan Speed Control Algorithm and will always limit the fan drive setting. That is, if the programmed fan drive setting (either as determined by the RPM-based Fan Speed Control Algorithm or by manual settings) exceeds the current fan drive setting by greater than the Fan Step Register setting, the EMC2301 will limit the fan drive change to the value of the Fan Step Register. It will use the Update Time to determine how often to update the drive settings. APPLICATION NOTE: If the Fan Speed Control Algorithm is used, the default settings in the Fan Configuration 2 Register will cause the maximum fan step settings to be ignored. The Fan Max Step register is software locked. 5.14 Fan Minimum Drive Register Table 5.24 Minimum Fan Drive Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 38h R/W Fan Minimum Drive 128 64 32 16 8 4 2 1 66h (40%) The Fan Minimum Drive register stores the minimum drive setting for the RPM-based Fan Speed Control Algorithm. The RPM-based Fan Speed Control Algorithm will not drive the fan at a level lower than the minimum drive unless the target Fan Speed is set at FFh (see Section 5.17). Revision 1.1 (10-12-09) 34 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet During normal operation, if the fan stops for any reason (including low drive), the RPM-based Fan Speed Control Algorithm will attempt to restart the fan. Setting the Fan Minimum Drive Register to a setting that will maintain fan operation is a useful way to avoid potential fan oscillations as the control circuitry attempts to drive it at a level that cannot support fan operation. The Fan Minimum Drive Register is software locked. 5.15 Valid TACH Count Register Table 5.25 Valid TACH Count Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 39h R/W Valid TACH Count 4096 2048 1024 512 256 128 64 32 F5h The Valid TACH Count register stores the maximum TACH Reading Register value to indicate that the fan is spinning properly. The value is referenced at the end of the Spin Up Routine to determine if the fan has started operating and decide if the device needs to retry. See Equation [2] in Section 5.18 for translating the count to an RPM. If the TACH Reading Register value exceeds the Valid TACH Count Register (indicating that the Fan RPM is below the threshold set by this count), then a stalled fan is detected. In this condition, the algorithm will automatically begin its Spin Up Routine. If a TACH Target setting is set above the Valid TACH Count setting, then that setting will be ignored and the algorithm will use the current fan drive setting. The Valid TACH Count register is software locked. 5.16 Fan Drive Fail Band Registers Table 5.26 Fan Drive Fail Band Registers ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 3Ah R/W Fan Drive Fail Band Low Byte 16 8 4 2 1 - - - 00h 3Bh R/W Fan Drive Fail Band High Byte 4096 2048 1024 512 256 128 64 32 00h The Fan Drive Fail Band Registers store the number of tach counts used by the Fan Drive Fail detection circuitry. This circuitry is activated when the fan drive setting high byte is at FFh. When it is enabled, the actual measured fan speed is compared against the target fan speed. These registers are only used when the FSC is active. This circuitry is used to indicate that the target fan speed at full drive is higher than the fan is actually capable of reaching. If the measured fan speed does not exceed the target fan speed minus the Fan Drive Fail Band Register settings for a period of time longer than set by the DRIVE_FAIL_CNTx[1:0] bits, then the DRIVE_FAIL status bit will be set and an interrupt generated. SMSC EMC2301 35 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet 5.17 TACH Target Registers Table 5.27 TACH Target Registers ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 3Ch R/W TACH Target Low Byte 16 8 4 2 1 - - - F8h 3Dh R/W TACH Target High Byte 4096 2048 1024 512 256 128 64 32 FFh The TACH Target Registers hold the target tachometer value that is maintained by the RPM-based Fan Speed Control Algorithm. The value in the TACH Target Registers will always reflect the current TACH Target value. If the algorithm is enabled, setting the TACH Target Register to FFh will disable the fan driver (set the fan drive setting to 0%). Setting the TACH Target to any other value (from a setting of FFh) will cause the algorithm to invoke the Spin Up Routine after which it will function normally. The Tach Target is not applied until the high byte is written. Once the high byte is written, the current value of both high and low bytes will be used as the next Tach target. 5.18 TACH Reading Registers Table 5.28 TACH Reading Registers ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 3Eh R Fan TACH 4096 2048 1024 512 256 128 64 32 FFh 3Fh R Fan TACH Low Byte 16 8 4 2 1 - - - F8h The TACH Reading Registers’ contents describe the current tachometer reading for the fan. By default, the data represents the fan speed as the number of 32kHz clock periods that occur for a single revolution of the fan. Equation [2] shows the detailed conversion from TACH measurement (COUNT) to RPM while Equation [3] shows the simplified translation of TACH Reading Register count to RPM assuming a 2-pole fan, measuring 5 edges, with a frequency of 32.768kHz. These equations are solved and tabulated for ease of use in AN17.4 RPM to TACH Counts Conversion. Whenever the high byte register is read, the corresponding low byte data will be loaded to internal shadow registers so that when the low byte is read, the data will always coincide with the previously read high byte. Revision 1.1 (10-12-09) 36 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet where: poles = number of poles of the fan (typically 2) 1 (n – 1) RPM = -------------------- × ---------------------------------- × f TACH × 60 ( poles ) 1 COUNT × ----m fTACH = the tachometer measurement frequency (typically 32.768kHz) [2] n = number of edges measured (typically 5 for a 2 pole fan) m = the multiplier defined by the RANGE bits 3,932,160 × m RPM = -------------------------------------COUNT 5.19 [3] COUNT = TACH Reading Register value (in decimal) Software Lock Register Table 5.29 Software Lock Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT EFh R/W Software Lock - - - - - - - LOCK 00h The Software Lock Register controls the software locking of critical registers. This register is software locked. Bit 0 - LOCK - this bit acts on all registers that are designated SWL. When this bit is set, the locked registers become read only and cannot be updated. 5.20 ‘0’ (default) - all SWL registers can be updated normally. ‘1’ - all SWL registers cannot be updated and a hard-reset is required to unlock them. Product ID Register Table 5.30 Product ID Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT FDh R Product ID 0 0 1 1 0 1 1 1 37h The Product ID Register contains a unique 8-bit word that identifies the product. SMSC EMC2301 37 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet 5.21 Manufacturer ID Register Table 5.31 Manufacturer ID Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT FEh R Manufacturer ID 0 1 0 1 1 1 0 1 5Dh The Manufacturer ID Register contains an 8-bit word that identifies SMSC. 5.22 Revision Register Table 5.32 Revision Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT FFh R Revision 1 0 0 0 0 0 0 0 80h The Revision Register contains an 8-bit word that identifies the die revision. Revision 1.1 (10-12-09) 38 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet Chapter 6 Typical Operating Curves The following Typical Operating Curves are included. Supply Current vs. Temperature Supply Current vs. Supply Voltage Fan TACH Accuracy vs. Temperature Fan TACH Accuracy vs. Supply Voltage PWM output frequency vs. Supply Voltage PWM output frequency vs. Temperature FSC Operation Supply Current vs. Supply Voltage 400 380 380 360 360 340 340 Supply Current (uA) Supply Current (uA) Supply Current vs. Ambient Temeperature 400 320 300 280 260 320 300 280 260 240 240 220 220 200 -50 200 2.95 0 50 Ambient Temperature (°C) 100 3.35 3.45 3.55 3.65 1 0.8 Tach Measurement Accuracy (%)(% Tach Measurement Accuracy Tach Measurement MeasurementAccuracy Accuracy(%) (% Tach 3.25 Tachometer Measurement Accuracy vs. Supply Voltage Tachometer Measurement Accuracy vs. Ambient Temperature 0.6 0.4 0.2 0 -0.2 -0.4 -0.6 -0.8 0 50 100 0.8 0.6 0.4 0.2 0 -0.2 -0.4 -0.6 -0.8 -1 2.95 150 3.05 3.15 3.25 3.35 3.45 3.55 3.65 Supply Voltage (V) (C) AmbientTemperautre Temperature (°C) SMSC EMC2301 3.15 Supply Voltage (V) 1 -1 -50 3.05 150 39 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet PWM Frequency vs. Ambient Temperature V DD = 3.3V, Base Frequncy = 26Khz PWM Frequency vs. Supply Voltage TA = 25C, Base Frequncy = 26Khz 27000 27000 26800 26800 26600 26400 PWM Frequency (Hz) PWM Frequency (Hz) 26600 26200 26000 25800 25600 25400 25200 26400 26200 26000 25800 25600 25400 25200 25000 -50 0 50 100 25000 2.95 150 3.05 T emp er at ur e ( C ) Ambient Temperature (°C) 3.15 3.25 3.35 3.45 3.55 3.65 Supply Voltage (V) FSC Algorithm Spin Up Routine – NoKick Spin Time = 1.0s; Spin Level = 50%; UpdateTime = 200ms; RPM Target from 0 RPM -> 8000 RPM @ time t = 0 FSC Algorithm Spin Up Routine Spin Time = 1.0s; Spin Level = 55%; Updated Time = 200ms; RPM Target from 0 RPM -> 8000 RPM @ time t = 0 PWM Output PWM Output 10x Zoom on PWM Output 10x Zoom on PWM Output Duty Cycle Measured = 53.8% t=0 t=0 Duty Cycle Measured = 50% FSC Algorithm PWM Ramping Update Time = 200ms; Max Step = 16 PWM counts RPM Target from 0 RPM -> 8000 RPM @ time t = 0 PWM Output 10x Zoom on PWM Output Spin Up Routine Ends – begins normal operation Update Time ends, PWM duty cycle changed Revision 1.1 (10-12-09) Duty Cycle Measured Update Time ends, PWM duty cycle changed 40 DATASHEET SMSC EMC2301 RPM-Based PWM Fan Controller Datasheet Chapter 7 Package Drawing 7.1 EMC2301 Package Information REVISIO N HIST ORY REVI SION 3 D P IN 1 IDE NTIFIER AR EA (D /2 X E1/2) e 3 DATE RELEASEDBY - - SEE SPEC FRONT PAGE FOR REVISI ONHISTORY 5 c E1 2 DESCRIPTION - E SEE DE TAIL "A" 8X b END VIEW TOP VIEW A2 A C SE ATING P LANE A1 ccc C SIDE VIEW 3-D VIEW 1. ALL DIMENSIONS ARE IN MILLIMETER. 2. TOLERANCE ON THE TRUE POSITI ON OF THE LEADS I S ± 0.065mm MAXIMUM. 3. PACKAGE BODY DIMENSIONS "D" AND "E1" DO NOT INCLUDE MOLD PROTRUSIONS OR FLASH. MAXIMUM MOLD PROTRUSIONS OR FLASH I S 0.15 mm (0.006 I NCHES) PER END AND SIDE. DIMENSIONS "D" AND "E1" ARE DETERMINED AT DATUM PLANE "H". 4. DIMENSION FOR FOOT LENGTH "L" IS MEASURED AT THE GAUGE PLANE 0.25mm ABOVE THE SEATING PLANE. 5. DETAILS OF PIN 1 IDENTIFIER ARE OPTIONAL, BUT MUST BE LOCATED WITHIN THE ZONE INDICATED. H C NOTES: GA U GE PLAN E 0.2 5 S EAT IN G PLAN E 0 ° - 8° 4 L UNLESS OTHERWISE SPECI FIED DIMENSIONS ARE IN MILL IMETERS AND TOLERANCES ARE: L1 DECI MAL X.X ±0 .1 X.XX ±0 .05 X.XXX ±0 .025 THIRD ANG L E PR OJ EC TIO N 80 ARKAY DRIVE HAUPPAUGE, NY 11 788 USA ANGULAR ±1° TITLE DETAIL "A" NAME DATE S .K.ILIEV 7 /0 5/04 DIM AND TOL PER ASME Y14. 5M - 1994 PACKAGE OUTLINE 8 PIN TSSOP, 3x 3 MM BO DY, 0.65 MM PITCH DRA WN M ATER IAL - SCALE: 3/1 FINISH CHE CKED - S .K.ILIEV S .K.ILIEV MO-8-TSSOP-3x3 7 /0 5/04 APP RO VED PRINT WIT H" SCALE TO FIT " DO NOT SCAL E DRAWING R EV D WG N UM BER S CALE 7 /0 7/04 STD CO M PLIANCE 1 :1 JED EC: MO-1 87 / D D SH EET 1 OF 1 Figure 7.1 EMC2301 Package Drawing - 8-Pin MSOP SMSC EMC2301 41 DATASHEET Revision 1.1 (10-12-09) RPM-Based PWM Fan Controller Datasheet 7.2 Package Markings TOP LINE: 1-T – Device Number LINE: 2-T Version, Revision, Country Code (VRCC) 2 3 0 1 2x 1.5pt 1 R C C e3 PB-FREE/GREEN SYMBOL (Matte Sn) ALL TOP LINES CENTER HORIZONTAL ALIGNMENT PIN 1 BOTTOM PIN 1 LINE: 1-B – Date Code (YYWW) Y Y WW LINE: 2-B – First 3 Digits of Lot Number 1 2 3 LINE: 3-B – Last 4 Digits of Lot Number 4 5 6 a 3x 1.5pt Figure 7.2 EMC2301 Package Markings Revision 1.1 (10-12-09) 42 DATASHEET SMSC EMC2301