Sparkle Power Inc. A Leading Power Supply Manufacturer Web site: www.sparklepower.com FSP400-70MP (Medical Grade, RoHS Compliant) 400 Watts ATX12V,EPS12V Switching Power Supply Features • Complied with ATX12V, EPS12V standard • Active Power Factor Correction (PFC) meet EN61000-3-2 • High efficiency and reliability • Compatible with European Union Directive 2002/95/EC (Restriction on Hazardous Substances). • Remote ON/OFF function • Internal 12V DC fan included • Noise Killer (thermal fan speed control function) • Low noise and ripple • Output over voltage, short circuit, and over current protection • 100% Hi-pot, ATE, and burn-in tested • Re-settable power shut down • Complies with FCC CFR 47 part 18 subpart C, 120Vac operation & EN60601-1-2, EN55011, 230VAC operation • Specification • storage & shipping: -20°C ~ +80°C • Humidity: 5 ~ 90% on operating, 5 ~ 95% on storage • Dielectric Withstand: Primary frame ground 1800V AC for 1 second • Input Characteristics Efficiency: 68% minimum at 115Vac and 230Vac on Full load. • Rise time: Less than 20ms • Hold-up Time: 20ms minimum at nominal input voltage • Power Good Signal: Power on delay time 100 ~ 500ms, off delay 1ms minimum (TTL and CMOS compatible) Approved by UL60601-1, CSA C22.2 NO. 601-1-M90, VDE EN60601-1, (CB Report), CE Temperature Range: Operating: 0°C ~ +50°C on full load; • Leakage Current: Less than 0.3mA at 264Vac, 63Hz • MTBF: 100,000 hours on maximum load at +25°C • Dimensions (LxWxH): 140x150x86mm / 5.5x5.9x3.4inch Input Range: 90 ~ 265Vac (RMS), Full Range Input Frequency: 47 ~ 63Hz Input Current: Max 8A (RMS) @ 115Vac, 4A (RMS) @ 230Vac Inrush Current: 60A @ 115Vac, 100A @ 230Vac at cold start Output Characteristics Output Voltage Minimum Load Maximum Load 0.5A 30A +3.3V 0.3A 30A +5V 1.0A 17A +12V1 1.0A 17A +12V2 0.0A 0.3A -5V 0.0A 0.8A -12V 0.0A 2.0A +5Vsb *+3.3V and +5V total output shall not exceed 180W *+3.3V, +5V and +12V total output shall not exceed 380W * Total output for this subject power supply is 400W Sparkle Power Inc. Main Office 1000 Rock Avenue San Jose, CA 95131 TEL: 408-519-8888 FAX: 408-519-9999 E-MAIL: [email protected] Load Reg. ± 5% ± 5% ± 5% ± 5% ± 10% ± 10% ± 5% Line Reg. ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% ± 1% Ripple & Noise 50mV P-P 50mV P-P 120mV P-P 120mV P-P 100mV P-P 120mV P-P 50mV P-P Sparkle Power Inc. Los Angeles Office 17071 Green Drive City of Industry, CA 91745 TEL: 626-839-7180 FAX: 626-839-3395 1 / 1禁禁禁禁禁禁 文文文文文文 文文文文文文 文文文文文文 OAD06050092-R1.pdf 發發發發 : 2006/7/17 6:23 下下