SST SST25VF020B-80-4I-SAE

2 Mbit SPI Serial Flash
SST25VF020B
SST25VF040B4Mb Serial Peripheral Interface (SPI) flash memory
Data Sheet
FEATURES:
• Single Voltage Read and Write Operations
– 2.7-3.6V
• Serial Interface Architecture
– SPI Compatible: Mode 0 and Mode 3
• High Speed Clock Frequency
– Up to 80 MHz
• Superior Reliability
– Endurance: 100,000 Cycles (typical)
– Greater than 100 years Data Retention
• Low Power Consumption:
– Active Read Current: 10 mA (typical)
– Standby Current: 5 µA (typical)
• Flexible Erase Capability
– Uniform 4 KByte sectors
– Uniform 32 KByte overlay blocks
– Uniform 64 KByte overlay blocks
• Fast Erase and Byte-Program:
– Chip-Erase Time: 35 ms (typical)
– Sector-/Block-Erase Time: 18 ms (typical)
– Byte-Program Time: 7 µs (typical)
• Auto Address Increment (AAI) Programming
– Decrease total chip programming time over
Byte-Program operations
• End-of-Write Detection
– Software polling the BUSY bit in Status Register
– Busy Status readout on SO pin in AAI Mode
• Hold Pin (HOLD#)
– Suspends a serial sequence to the memory
without deselecting the device
• Write Protection (WP#)
– Enables/Disables the Lock-Down function of the
status register
• Software Write Protection
– Write protection through Block-Protection bits in
status register
• Temperature Range
– Commercial: 0°C to +70°C
– Industrial: -40°C to +85°C
• Packages Available
– 8-lead SOIC (150 mils)
– 8-contact WSON (6mm x 5mm)
• All non-Pb (lead-free) devices are RoHS compliant
PRODUCT DESCRIPTION
The 25 series Serial Flash family features a four-wire, SPIcompatible interface that allows for a low pin-count package which occupies less board space and ultimately lowers
total system costs. The SST25VF020B devices are
enhanced with improved operating frequency and even
lower power consumption. SST25VF020B SPI serial flash
memories are manufactured with SST proprietary, highperformance CMOS SuperFlash technology. The split-gate
cell design and thick-oxide tunneling injector attain better
reliability and manufacturability compared with alternate
approaches.
©2010 Silicon Storage Technology, Inc.
S71417-02-000
04/10
1
The SST25VF020B devices significantly improve performance and reliability, while lowering power consumption.
The devices write (Program or Erase) with a single power
supply of 2.7-3.6V for SST25VF020B. The total energy
consumed is a function of the applied voltage, current, and
time of application. Since for any given voltage range, the
SuperFlash technology uses less current to program and
has a shorter erase time, the total energy consumed during
any Erase or Program operation is less than alternative
flash memory technologies.
The SST25VF020B device is offered in 8-lead SOIC (150
mils) and 8-contact WSON (6mm x 5mm) packages. See
Figure 2 for pin assignments.
The SST logo and SuperFlash are registered Trademarks of Silicon Storage Technology, Inc.
These specifications are subject to change without notice.
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
SuperFlash
Memory
X - Decoder
Address
Buffers
and
Latches
Y - Decoder
I/O Buffers
and
Data Latches
Control Logic
Serial Interface
CE#
SCK
SI
SO
WP#
HOLD#
1417 B1.0
FIGURE 1: Functional Block Diagram
©2010 Silicon Storage Technology, Inc.
S71417-02-000
2
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
PIN DESCRIPTION
CE#
1
8
VDD
SO
2
7
HOLD#
CE#
1
SO
2
8
VDD
7
HOLD#
Top View
Top View
WP#
3
6
SCK
WP#
3
6
SCK
VSS
4
5
SI
VSS
4
5
SI
8-Contact WSON
8-Lead SOIC
1417 08-wson QA P2.0
1417 08-soic S2A P1.0
FIGURE 2: Pin Assignments
TABLE 1: Pin Description
Symbol
Pin Name
Functions
SCK
Serial Clock
To provide the timing of the serial interface.
Commands, addresses, or input data are latched on the rising edge of the clock input,
while output data is shifted out on the falling edge of the clock input.
SI
Serial Data Input
To transfer commands, addresses, or data serially into the device.
Inputs are latched on the rising edge of the serial clock.
SO
Serial Data Output
To transfer data serially out of the device.
Data is shifted out on the falling edge of the serial clock.
Outputs Flash busy status during AAI Programming when reconfigured as RY/BY# pin.
See “Hardware End-of-Write Detection” on page 12 for details.
CE#
Chip Enable
The device is enabled by a high to low transition on CE#. CE# must remain low for the
duration of any command sequence.
WP#
Write Protect
The Write Protect (WP#) pin is used to enable/disable BPL bit in the status register.
HOLD#
Hold
To temporarily stop serial communication with SPI flash memory without resetting the
device.
VDD
Power Supply
To provide power supply voltage: 2.7-3.6V for SST25VF020B
VSS
Ground
T1.0 1417
©2010 Silicon Storage Technology, Inc.
S71417-02-000
3
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
MEMORY ORGANIZATION
The SST25VF020B supports both Mode 0 (0,0) and Mode
3 (1,1) of SPI bus operations. The difference between the
two modes, as shown in Figure 3, is the state of the SCK
signal when the bus master is in Stand-by mode and no
data is being transferred. The SCK signal is low for Mode 0
and SCK signal is high for Mode 3. For both modes, the
Serial Data In (SI) is sampled at the rising edge of the SCK
clock signal and the Serial Data Output (SO) is driven after
the falling edge of the SCK clock signal.
The SST25VF020B SuperFlash memory array is organized in uniform 4 KByte erasable sectors with 32 KByte
overlay blocks and 64 KByte overlay erasable blocks.
DEVICE OPERATION
The SST25VF020B is accessed through the SPI (Serial
Peripheral Interface) bus compatible protocol. The SPI bus
consist of four control lines; Chip Enable (CE#) is used to
select the device, and data is accessed through the Serial
Data Input (SI), Serial Data Output (SO), and Serial Clock
(SCK).
CE#
SCK
SI
MODE 3
MODE 3
MODE 0
MODE 0
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
MSB
HIGH IMPEDANCE
DON'T CARE
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
SO
MSB
1417 SPIprot.0
FIGURE 3: SPI Protocol
©2010 Silicon Storage Technology, Inc.
S71417-02-000
4
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
Hold Operation
coincide with the SCK active low state, then the device
exits in Hold mode when the SCK next reaches the active
low state. See Figure 4 for Hold Condition waveform.
The HOLD# pin is used to pause a serial sequence underway with the SPI flash memory without resetting the clocking sequence. To activate the HOLD# mode, CE# must be
in active low state. The HOLD# mode begins when the
SCK active low state coincides with the falling edge of the
HOLD# signal. The HOLD mode ends when the HOLD#
signal’s rising edge coincides with the SCK active low state.
Once the device enters Hold mode, SO will be in highimpedance state while SI and SCK can be VIL or VIH.
If CE# is driven high during a Hold condition, the device
returns to Standby mode. As long as HOLD# signal is low,
the memory remains in the Hold condition. To resume
communication with the device, HOLD# must be driven
active high, and CE# must be driven active low. See Figure
4 for Hold timing.
If the falling edge of the HOLD# signal does not coincide
with the SCK active low state, then the device enters Hold
mode when the SCK next reaches the active low state.
Similarly, if the rising edge of the HOLD# signal does not
SCK
HOLD#
Active
Hold
Active
Hold
Active
1417 HoldCond.0
FIGURE 4: Hold Condition Waveform
Write Protection
TABLE 2: Conditions to execute Write-StatusRegister (WRSR) Instruction
SST25VF020B provides software Write protection. The
Write Protect pin (WP#) enables or disables the lock-down
function of the status register. The Block-Protection bits
(BP1, BP0, and BPL) in the status register, and the Top/
Bottom Sector Protection Status bits (TSP and BSP) in
Status Register 1, provide Write protection to the memory
array and the status register. See Table 5 for the Block-Protection description.
WP#
BPL
L
1
Execute WRSR Instruction
Not Allowed
L
0
Allowed
H
X
Allowed
T2.0 1417
Write Protect Pin (WP#)
The Write Protect (WP#) pin enables the lock-down function of the BPL bit (bit 7) in the status register. When WP#
is driven low, the execution of the Write-Status-Register
(WRSR) instruction is determined by the value of the BPL
bit (see Table 2). When WP# is high, the lock-down function of the BPL bit is disabled.
©2010 Silicon Storage Technology, Inc.
S71417-02-000
5
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
Status Register
Program operation, the status register may be read only to
determine the completion of an operation in progress.
Table 3 describes the function of each bit in the software
status register.
The software status register provides status on whether the
flash memory array is available for any Read or Write operation, whether the device is Write enabled, and the state of
the Memory Write protection. During an internal Erase or
TABLE 3: Software Status Register
Default at
Power-up
Read/Write
1 = Internal Write operation is in progress
0 = No internal Write operation is in progress
0
R
WEL
1 = Device is memory Write enabled
0 = Device is not memory Write enabled
0
R
2
BP0
Indicates current level of block write protection (See Table 5)
1
R/W
3
BP1
Indicates current level of block write protection (See Table 5)
1
R/W
4:5
RES
Reserved for future use
0
N/A
6
AAI
Auto Address Increment Programming status
1 = AAI programming mode
0 = Byte-Program mode
0
R
7
BPL
1 = BP1, BP0 are read-only bits
0 = BP1, BP0 are read/writable
0
R/W
Bit
Name
Function
0
BUSY
1
T3.0 1417
Software Status Register 1
The Software Status Register 1 is an additional register
that contains Top Sector and Bottom Sector Protection bits.
These register bits are read/writable and determine the
lock and unlock status of the top and bottom sectors.
Table 4 describes the function of each bit in the Software
Status Register 1.
TABLE 4: Software Status Register 1
Bit
Default at
Power-up
Name
Function
Read/Write
0:1
RES
Reserved for future use
0
N/A
2
TSP
Top Sector Protection status
1 = Indicates highest sector is write locked
0 = Indicates highest sector is Write accessible
0
R/W
3
BSP
Bottom Sector Protection status
1 = Indicates lowest sector is write locked
0 = Indicates lowest sector is Write accessible
0
R/W
4:7
RES
Reserved for future use
0
N/A
T4.0 1417
Busy
Write Enable Latch (WEL)
The Busy bit determines whether there is an internal Erase
or Program operation in progress. A “1” for the Busy bit indicates the device is busy with an operation in progress. A “0”
indicates the device is ready for the next valid operation.
The Write-Enable-Latch bit indicates the status of the internal memory Write Enable Latch. If the Write-Enable-Latch
bit is set to “1”, it indicates the device is Write enabled. If the
bit is set to “0” (reset), it indicates the device is not Write
enabled and does not accept any memory Write (Program/
Erase) commands. The Write-Enable-Latch bit is automatically reset under the following conditions:
©2010 Silicon Storage Technology, Inc.
S71417-02-000
6
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
•
•
•
•
•
•
•
•
Block Protection (BP1, BP0)
Power-up
Write-Disable (WRDI) instruction completion
Byte-Program instruction completion
Auto Address Increment (AAI) programming is
completed or reached its highest unprotected
memory address
Sector-Erase instruction completion
Block-Erase instruction completion
Chip-Erase instruction completion
Write-Status-Register instructions
The Block-Protection (BP1, BP0) bits define the size of the
memory area, as defined in Table 5, to be software protected against any memory Write (Program or Erase)
operation. The Write-Status-Register (WRSR) instruction
is used to program the BP1 and BP0 bits as long as WP#
is high or the Block-Protect-Lock (BPL) bit is 0. Chip-Erase
can only be executed if Block-Protection bits are all 0. After
power-up, BP1 and BP0 are set to 1.
Block Protection Lock-Down (BPL)
WP# pin driven low (VIL), enables the Block-ProtectionLock-Down (BPL) bit. When BPL is set to 1, it prevents any
further alteration of the BPL, BP1, and BP0 bits of the status register and BSP and TSP of Status Register 1. When
the WP# pin is driven high (VIH), the BPL bit has no effect
and its value is “Don’t Care”. After power-up, the BPL bit is
reset to 0.
Auto Address Increment (AAI)
The Auto Address Increment Programming-Status bit provides status on whether the device is in AAI programming
mode or Byte-Program mode. The default at power up is
Byte-Program mode.
TABLE 5: Software Status Register Block Protection FOR SST25VF020B1
Status Register Bit2
Protection Level
BP1
BP0
Protected Memory Address
2 Mbit
0
0
0
None
1 (1/4 Memory Array)
0
1
030000H-03FFFFH
1 (1/2 Memory Array)
1
0
020000H-03FFFFH
1 (Full Memory Array)
1
1
000000H-03FFFFH
T5.0 1417
1. X = Don’t Care (RESERVED) default is “0
2. Default at power-up for BP1 and BP0 is ‘11’. (All Blocks Protected)
Top-Sector Protection/Bottom-Sector Protection
The Top-Sector Protection (TSP) and Bottom-Sector Protection (BSP) bits independently indicate whether the highest and lowest sector locations are Write locked or Write
accessible. When TSP or BSP is set to ‘1’, the respective
sector is Write locked; when set to ‘0’ the respective sector
is Write accessible. If TSP or BSP is set to '1' and if the top
or bottom sector is within the boundary of the target
address range of the program or erase instruction, the initiated instruction (Byte-Program, AAI-Word Program, Sector-Erase, Block-Erase, and Chip-Erase) will not be
executed. Upon power-up, the TSP and BSP bits are automatically reset to ‘0’.
©2010 Silicon Storage Technology, Inc.
S71417-02-000
7
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
Instructions
of SCK starting with the most significant bit. CE# must be
driven low before an instruction is entered and must be
driven high after the last bit of the instruction has been
shifted in (except for Read, Read-ID, and Read-StatusRegister instructions). Any low to high transition on CE#,
before receiving the last bit of an instruction bus cycle, will
terminate the instruction in progress and return the device
to standby mode. Instruction commands (Op Code),
addresses, and data are all input from the most significant
bit (MSB) first.
Instructions are used to read, write (Erase and Program),
and configure the SST25VF020B. The instruction bus
cycles are 8 bits each for commands (Op Code), data, and
addresses. Prior to executing any Byte-Program, Auto
Address Increment (AAI) programming, Sector-Erase,
Block-Erase, Write-Status-Register, or Chip-Erase instructions, the Write-Enable (WREN) instruction must be executed first. The complete list of instructions is provided in
Table 6. All instructions are synchronized off a high to low
transition of CE#. Inputs will be accepted on the rising edge
TABLE 6: Device Operation Instructions
Instruction
Description
Op Code Cycle1
Address
Cycle(s)2
Dummy
Cycle(s)
Data
Cycle(s)
Read
Read Memory
0000 0011b (03H)
3
0
1 to ∞
High-Speed Read
Read Memory at higher speed
4 KByte Sector-Erase3 Erase 4 KByte of memory array
32 KByte
Block-Erase4
0000 1011b (0BH)
3
1
1 to ∞
0010 0000b (20H)
3
0
0
Erase 32 KByte block of memory array 0101 0010b (52H)
3
0
0
64 KByte Block-Erase5 Erase 64 KByte block of memory array 1101 1000b (D8H)
3
0
0
Chip-Erase
Erase Full Memory Array
0110 0000b (60H) or
1100 0111b (C7H)
0
0
0
Byte-Program
To Program One Data Byte
0000 0010b (02H)
3
0
1
AAI-Word-Program6
Auto Address Increment Programming 1010 1101b (ADH)
3
0
2 to ∞
RDSR7
Read-Status-Register
0000 0101b (05H)
0
0
1 to ∞
RDSR1
Read-Status-Register 1
0011 0101b (35H)
0
0
1 to ∞
EWSR
Enable-Write-Status-Register
0101b 0000b (50H)
0
0
0
WRSR
Write-Status-Register
0000 0001b (01H)
0
0
1 or 2
WREN
Write-Enable
0000 0110b (06H)
0
0
0
WRDI
Write-Disable
0000 0100b (04H)
0
0
0
RDID8
Read-ID
1001 0000b (90H) or
1010 1011b (ABH)
3
0
1 to ∞
JEDEC-ID
JEDEC ID read
1001 1111b (9FH)
0
0
3 to ∞
EBSY
Enable SO to output RY/BY# status
during AAI programming
0111 0000b (70H)
0
0
0
DBSY
Disable SO to output RY/BY# status
during AAI programming
1000 0000b (80H)
0
0
0
T6.0
1417
1.
2.
3.
4.
5.
6.
One bus cycle is eight clock periods.
Address bits above the most significant bit of each density can be VIL or VIH.
4KByte Sector Erase addresses: use AMS-A12, remaining addresses are don’t care but must be set either at VIL or VIH.
32KByte Block Erase addresses: use AMS-A15, remaining addresses are don’t care but must be set either at VIL or VIH.
64KByte Block Erase addresses: use AMS-A16, remaining addresses are don’t care but must be set either at VIL or VIH.
To continue programming to the next sequential address location, enter the 8-bit command, ADH, followed by 2 bytes of data to be
programmed. Data Byte 0 will be programmed into the initial address [A23-A1] with A0=0, Data Byte 1 will be programmed into the
initial address [A23-A1] with A0=1.
7. The Read-Status-Register is continuous with ongoing clock cycles until terminated by a low to high transition on CE#.
8. Manufacturer’s ID is read with A0=0, and Device ID is read with A0=1. All other address bits are 00H. The Manufacturer’s ID and
device ID output stream is continuous until terminated by a low-to-high transition on CE#.
©2010 Silicon Storage Technology, Inc.
S71417-02-000
8
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
Read (33 MHz)
beginning (wrap-around) of the address space. Once the
data from address location 3FFFFH has been read, the
next output will be from address location 000000H.
The Read instruction, 03H, supports up to 33 MHz Read.
The device outputs the data starting from the specified
address location. The data output stream is continuous
through all addresses until terminated by a low to high transition on CE#. The internal address pointer will automatically increment until the highest memory address is
reached. Once the highest memory address is reached,
the address pointer will automatically increment to the
The Read instruction is initiated by executing an 8-bit command, 03H, followed by address bits [A23-A0]. CE# must
remain active low for the duration of the Read cycle. See
Figure 5 for the Read sequence.
CE#
MODE 3
SCK
0 1 2 3 4 5 6 7 8
15 16
23 24
31 32
39 40
47
48
55 56
63 64
70
MODE 0
ADD.
03
SI
MSB
SO
ADD.
ADD.
MSB
N
DOUT
HIGH IMPEDANCE
N+1
DOUT
N+2
DOUT
N+3
DOUT
N+4
DOUT
MSB
1417 ReadSeq.0
FIGURE 5: Read Sequence
©2010 Silicon Storage Technology, Inc.
S71417-02-000
9
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
High-Speed-Read (80 MHz)
addresses until terminated by a low to high transition on
CE#. The internal address pointer will automatically increment until the highest memory address is reached. Once
the highest memory address is reached, the address
pointer will automatically increment to the beginning (wraparound) of the address space. Once the data from address
location 3FFFH has been read, the next output will be from
address location 00000H.
The High-Speed-Read instruction supporting up to 80 MHz
Read is initiated by executing an 8-bit command, 0BH, followed by address bits [A23-A0] and a dummy byte. CE#
must remain active low for the duration of the High-SpeedRead cycle. See Figure 6 for the High-Speed-Read
sequence.
Following a dummy cycle, the High-Speed-Read instruction outputs the data starting from the specified address
location. The data output stream is continuous through all
CE#
MODE 3
SCK
0 1 2 3 4 5 6 7 8
15 16
23 24
31 32
39 40
47 48
55 56
63 64
71 72
80
MODE 0
0B
SI
MSB
ADD.
MSB
ADD.
ADD.
N
DOUT
HIGH IMPEDANCE
SO
X
N+1
DOUT
N+2
DOUT
N+3
DOUT
N+4
DOUT
MSB
Note: X = Dummy Byte: 8 Clocks Input Dummy Cycle (VIL or VIH)
1417 HSRdSeq.0
FIGURE 6: High-Speed-Read Sequence
©2010 Silicon Storage Technology, Inc.
S71417-02-000
10
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
Byte-Program
Program instruction is initiated by executing an 8-bit command, 02H, followed by address bits [A23-A0]. Following the
address, the data is input in order from MSB (bit 7) to LSB
(bit 0). CE# must be driven high before the instruction is
executed. The user may poll the Busy bit in the software
status register or wait TBP for the completion of the internal
self-timed Byte-Program operation. See Figure 7 for the
Byte-Program sequence.
The Byte-Program instruction programs the bits in the
selected byte to the desired data. The selected byte must
be in the erased state (FFH) when initiating a Program
operation. A Byte-Program instruction applied to a protected memory area will be ignored.
Prior to any Write operation, the Write-Enable (WREN)
instruction must be executed. CE# must remain active low
for the duration of the Byte-Program instruction. The Byte-
CE#
MODE 3
SCK
0 1 2 3 4 5 6 7 8
15 16
23 24
31 32
39
MODE 0
02
SI
MSB
SO
ADD.
ADD.
MSB
ADD.
DIN
MSB
LSB
HIGH IMPEDANCE
1417 ByteProg.0
FIGURE 7: Byte-Program Sequence
©2010 Silicon Storage Technology, Inc.
S71417-02-000
11
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
User must check busy status after WRDI to determine if the
device is ready for any command. See Figures 10 and 11
for AAI Word programming sequence.
Auto Address Increment (AAI) Word-Program
The AAI program instruction allows multiple bytes of data to
be programmed without re-issuing the next sequential
address location. This feature decreases total programming time when multiple bytes or entire memory array is to
be programmed. An AAI Word program instruction pointing
to a protected memory area will be ignored. The selected
address range must be in the erased state (FFH) when initiating an AAI Word Program operation. While within AAI
Word Programming sequence, the only valid instructions
are AAI Word (ADH), RDSR (05H), or WRDI (04H). Users
have three options to determine the completion of each
AAI Word program cycle: hardware detection by reading
the Serial Output, software detection by polling the BUSY
bit in the software status register or wait TBP. Refer to EndOf-Write Detection section for details.
There is no wrap mode during AAI programming; once the
highest unprotected memory address is reached, the
device will exit AAI operation and reset the Write-EnableLatch bit (WEL = 0) and the AAI bit (AAI=0).
End-of-Write Detection
There are three methods to determine completion of a program cycle during AAI Word programming: hardware
detection by reading the Serial Output, software detection
by polling the BUSY bit in the Software Status Register or
wait TBP. The hardware end-of-write detection method is
described in the section below.
Hardware End-of-Write Detection
Prior to any write operation, the Write-Enable (WREN)
instruction must be executed. The AAI Word Program
instruction is initiated by executing an 8-bit command,
ADH, followed by address bits [A23-A0]. Following the
addresses, two bytes of data is input sequentially, each one
from MSB (Bit 7) to LSB (Bit 0). The first byte of data (D0)
will be programmed into the initial address [A23-A1] with
A0=0, the second byte of Data (D1) will be programmed
into the initial address [A23-A1] with A0=1. CE# must be
driven high before the AAI Word Program instruction is executed. The user must check the BUSY status before entering the next valid command. Once the device indicates it is
no longer busy, data for the next two sequential addresses
may be programmed and so on. When the last desired
byte had been entered, check the busy status using the
hardware method or the RDSR instruction and execute the
Write-Disable (WRDI) instruction, 04H, to terminate AAI.
The hardware end-of-write detection method eliminates the
overhead of polling the Busy bit in the Software Status
Register during an AAI Word program operation. The 8-bit
command, 70H, configures the Serial Output (SO) pin to
indicate Flash Busy status during AAI Word programming.
(see Figure 8) The 8-bit command, 70H, must be executed
prior to executing an AAI Word-Program instruction. Once
an internal programming operation begins, asserting CE#
will immediately drive the status of the internal flash status
on the SO pin. A “0” indicates the device is busy and a “1”
indicates the device is ready for the next instruction. Deasserting CE# will return the SO pin to tri-state.
The 8-bit command, 80H, disables the Serial Output (SO)
pin to output busy status during AAI-Word-program operation and return SO pin to output Software Status Register
data during AAI Word programming. (see Figure 9)
CE#
MODE 3
SCK
0 1 2 3 4 5 6 7
MODE 0
70
SI
MSB
SO
HIGH IMPEDANCE
1417 EnableSO.0
FIGURE 8: Enable SO as Hardware RY/BY# during AAI Programming
©2010 Silicon Storage Technology, Inc.
S71417-02-000
12
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
CE#
MODE 3
SCK
0 1 2 3 4 5 6 7
MODE 0
80
SI
MSB
HIGH IMPEDANCE
SO
1417 DisableSO.0
FIGURE 9: Disable SO as Hardware RY/BY# during AAI Programming
CE#
MODE 3
SCK
SI
0
7 8
15 16 23 24
31 32 39 40 47
0
7 8
15 16 23
0
7 8
15 16 23
0
7
0
7 8
15
MODE 0
AD
A
A
A
D0
D1
AD
D2
D3
AD
Dn-1
Dn
Last 2
Data Bytes
Load AAI command, Address, 2 bytes data
WRDI
RDSR
WDRI to exit
AAI Mode
SO
DOUT
Check for Flash Busy Status to load next valid1 command
Note:
Wait TBP or poll
Software Status register
to load any command
1. Valid commands during AAI programming: AAI command or WRDI command
2. User must configure the SO pin to output Flash Busy status during AAI programming
1417 AAI.HW.0
FIGURE 10: Auto Address Increment (AAI) Word-Program Sequence with
Hardware End-of-Write Detection
©2010 Silicon Storage Technology, Inc.
S71417-02-000
13
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
Wait TBP or poll Software Status
register to load next valid1 command
CE#
MODE 3
SCK
SI
0
7 8
15 16 23 24
31 32 39 40 47
0
7 8
15 16 23
0
7 8
15 16 23
0
7
0
7 8
15
MODE 0
AD
A
A
A
D0
D1
AD
D2
D3
AD
Dn-1
Dn
Last 2
Data Bytes
Load AAI command, Address, 2 bytes data
SO
WRDI
RDSR
WDRI to exit
AAI Mode
DOUT
Note:
1. Valid commands during AAI programming: AAI command or WRDI command
Wait TBP or poll
Software Status register
to load any command
1417 AAI.SW.0
FIGURE 11: Auto Address Increment (AAI) Word-Program Sequence with
Software End-of-Write Detection
©2010 Silicon Storage Technology, Inc.
S71417-02-000
14
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
4-KByte Sector-Erase
The Sector-Erase instruction clears all bits in the selected 4
KByte sector to FFH. A Sector-Erase instruction applied to
a protected memory area will be ignored. Prior to any Write
operation, the Write-Enable (WREN) instruction must be
executed. CE# must remain active low for the duration of
any command sequence. The Sector-Erase instruction is
initiated by executing an 8-bit command, 20H, followed by
address bits [A23-A0]. Address bits [AMS-A12] (AMS = Most
Significant address) are used to determine the sector
address (SAX), remaining address bits can be VIL or VIH.
CE# must be driven high before the instruction is executed.
The user may poll the Busy bit in the software status register or wait TSE for the completion of the internal self-timed
Sector-Erase cycle. See Figure 12 for the Sector-Erase
sequence.
CE#
MODE 3
SCK
0 1 2 3 4 5 6 7 8
15 16
23 24
31
MODE 0
ADD.
20
SI
MSB
SO
ADD.
ADD.
MSB
HIGH IMPEDANCE
1417 SecErase.0
FIGURE 12: Sector-Erase Sequence
©2010 Silicon Storage Technology, Inc.
S71417-02-000
15
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
32-KByte and 64-KByte Block-Erase
The 32-KByte Block-Erase instruction clears all bits in the
selected 32 KByte block to FFH. A Block-Erase instruction
applied to a protected memory area will be ignored. The
64-KByte Block-Erase instruction clears all bits in the
selected 64 KByte block to FFH. A Block-Erase instruction
applied to a protected memory area will be ignored. Prior to
any Write operation, the Write-Enable (WREN) instruction
must be executed. CE# must remain active low for the
duration of any command sequence. The 32-Kbyte BlockErase instruction is initiated by executing an 8-bit command, 52H, followed by address bits [A23-A0]. Address bits
[AMS-A15] (AMS = Most Significant Address) are used to
determine block address (BAX), remaining address bits can
be VIL or VIH. CE# must be driven high before the instruction
is executed. The 64-Kbyte Block-Erase instruction is initiated by executing an 8-bit command D8H, followed by
address bits [A23-A0]. Address bits [AMS-A15] are used to
determine block address (BAX), remaining address bits can
be VIL or VIH. CE# must be driven high before the instruction
is executed. The user may poll the Busy bit in the software
status register or wait TBE for the completion of the internal
self-timed 32-KByte Block-Erase or 64-KByte Block-Erase
cycles. See Figures 13 and 14 for the 32-KByte BlockErase and 64-KByte Block-Erase sequences.
CE#
MODE 3
SCK
0 1 2 3 4 5 6 7 8
15 16
23 24
31
MODE 0
ADDR
ADDR
52
SI
MSB
ADDR
MSB
HIGH IMPEDANCE
SO
1417 32KBklEr.0
FIGURE 13: 32-KByte Block-Erase Sequence
CE#
MODE 3
SCK
0 1 2 3 4 5 6 7 8
15 16
23 24
31
MODE 0
ADDR
D8
SI
MSB
SO
ADDR
ADDR
MSB
HIGH IMPEDANCE
1417 63KBlkEr.0
FIGURE 14: 64-KByte Block-Erase Sequence
©2010 Silicon Storage Technology, Inc.
S71417-02-000
16
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
Chip-Erase
by executing an 8-bit command, 60H or C7H. CE# must be
driven high before the instruction is executed. The user may
poll the Busy bit in the software status register or wait TCE
for the completion of the internal self-timed Chip-Erase
cycle. See Figure 15 for the Chip-Erase sequence.
The Chip-Erase instruction clears all bits in the device to
FFH. A Chip-Erase instruction will be ignored if any of the
memory area is protected. Prior to any Write operation, the
Write-Enable (WREN) instruction must be executed. CE#
must remain active low for the duration of the Chip-Erase
instruction sequence. The Chip-Erase instruction is initiated
CE#
MODE 3
SCK
0 1 2 3 4 5 6 7
MODE 0
60 or C7
SI
MSB
HIGH IMPEDANCE
SO
1417 ChEr.0
FIGURE 15: Chip-Erase Sequence
Read-Status-Register (RDSR)
CE# must be driven low before the RDSR instruction is
entered and remain low until the status data is read. ReadStatus-Register is continuous with ongoing clock cycles
until it is terminated by a low to high transition of the CE#.
See Figure 16 for the RDSR instruction sequence.
The Read-Status-Register (RDSR) instruction allows reading of the status register. The Status Register may be read
at any time even during a Write (Program/Erase) operation.
When a Write operation is in progress, the Busy bit may be
checked before sending any new commands to assure that
the new commands are properly received by the device.
CE#
MODE 3
SCK
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
MODE 0
SI
05
MSB
HIGH IMPEDANCE
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
SO
MSB
Status
Register Out
1417 RDSRseq.0
FIGURE 16: Read-Status-Register (RDSR) Sequence
Read-Status-Register (RDSR1)
The Read-Status-Register 1 (RDSR1) instruction allows
reading of the status register 1. CE# must be driven low
before the RDSR instruction is entered and remain low until
the status data is read. Read-Status-Register 1 is continuous with ongoing clock cycles until it is terminated by a low
to high transition of the CE#. See Figure 17 for the RDSR
instruction sequence.
©2010 Silicon Storage Technology, Inc.
S71417-02-000
17
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
CE#
MODE 3
SCK
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
MODE 0
SI
35
MSB
HIGH IMPEDANCE
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
SO
MSB
Status
Register Out
1417 RDSR1seq.0
FIGURE 17: Read-Status-Register 1 (RDSR1) Sequence
Write-Enable (WREN)
the Write-Status-Register (WRSR) instruction; however,
the Write-Enable-Latch bit in the Status Register will be
cleared upon the rising edge CE# of the WRSR instruction.
CE# must be driven high before the WREN instruction is
executed.
The Write-Enable (WREN) instruction sets the WriteEnable-Latch bit in the Status Register to 1 allowing Write
operations to occur. The WREN instruction must be executed prior to any Write (Program/Erase) operation. The
WREN instruction may also be used to allow execution of
CE#
MODE 3
SCK
0 1 2 3 4 5 6 7
MODE 0
06
SI
MSB
SO
HIGH IMPEDANCE
1417 WREN.0
FIGURE 18: Write Enable (WREN) Sequence
Write-Disable (WRDI)
The Write-Disable (WRDI) instruction resets the WriteEnable-Latch bit and AAI bit to 0 disabling any new Write
operations from occurring. The WRDI instruction will not
terminate any programming operation in progress. Any program operation in progress may continue up to TBP after
executing the WRDI instruction. CE# must be driven high
before the WRDI instruction is executed.
©2010 Silicon Storage Technology, Inc.
S71417-02-000
18
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
CE#
MODE 3
SCK
0 1 2 3 4 5 6 7
MODE 0
04
SI
MSB
SO
HIGH IMPEDANCE
1417 WRDI.0
FIGURE 19: Write Disable (WRDI) Sequence
Enable-Write-Status-Register (EWSR)
The Enable-Write-Status-Register (EWSR) instruction
arms the Write-Status-Register (WRSR) instruction and
opens the status register for alteration. The Write-StatusRegister instruction must be executed immediately after the
execution of the Enable-Write-Status-Register instruction.
This two-step instruction sequence of the EWSR instruction followed by the WRSR instruction works like SDP (software data protection) command structure which prevents
any accidental alteration of the status register values. CE#
must be driven low before the EWSR instruction is entered
and must be driven high before the EWSR instruction is
executed.
©2010 Silicon Storage Technology, Inc.
S71417-02-000
19
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
Write-Status-Register (WRSR)
BPL bit is disabled and the BPL, BP0, and BP1 bits in the
status register can all be changed. As long as BPL bit is set
to 0 or WP# pin is driven high (VIH) prior to the low-to-high
transition of the CE# pin at the end of the WRSR instruction, the bits in the status register can all be altered by the
WRSR instruction. In this case, a single WRSR instruction
can set the BPL bit to “1” to lock down the status register as
well as altering the BP0, BP1, and BP2 bits at the same
time. See Table 2 for a summary description of WP# and
BPL functions.
The Write-Status-Register instruction writes new values to
the BP1, BP0, and BPL bits of the status register. CE#
must be driven low before the command sequence of the
WRSR instruction is entered and driven high before the
WRSR instruction is executed. See Figure 20 for EWSR or
WREN and WRSR for byte-data input sequences.
Executing the Write-Status-Register instruction will be
ignored when WP# is low and BPL bit is set to “1”. When
the WP# is low, the BPL bit can only be set from “0” to “1” to
lock-down the status register, but cannot be reset from “1”
to “0”. When WP# is high, the lock-down function of the
CE#
MODE 3
SCK
0 1 2 3 4 5 6 7
MODE 0
MODE 3
50 or 06
SI
01
MSB
SO
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
MODE 0
MSB
STATUS
REGISTER IN
7 6 5 4 3 2 1 0
MSB
HIGH IMPEDANCE
1417 EWSR.0
FIGURE 20: Enable-Write-Status-Register (EWSR) or
Write-Enable (WREN) and Write-Status-Register (WRSR) Byte-Data Input Sequence
lock-down the status registers, but cannot be reset from ‘1’
to ‘0’. When WP# is high, the lock-down function of the BPL
bit is disabled and the BPL, BP0, BP1, TSP, and BSP bits
in the status register can all be changed. As long as BPL bit
is set to 0 or WP# pin is driven high (VIH) prior to the low-tohigh transition of the CE# pin at the end of the WRSR
instruction, the bits in the status register can all be altered
by the WRSR instruction. In this case, a single WRSR
instruction can set the BPL bit to “1” to lock down the status
register as well as altering the BPL, BP0, BP1, TSP, and
BSP bits at the same time. See Table 2 for a summary
description of WP# and BPL functions.
The Write-Status-Register instruction also writes new values to the Status Register 1. To write values to Status
Register 1, the WRSR sequence needs a word-data
input—the first byte being the Status Register bits, followed
by the second byte Status Register 1 bits. CE# must be
driven low before the command sequence of the WRSR
instruction is entered and driven high before the WRSR
instruction is executed. See Figure 21 for EWSR or WREN
and WRSR instruction word-data input sequences.
Executing the Write-Status-Register instruction will be
ignored when WP# is low and BPL bit is set to ‘1’. When
the WP# is low, the BPL bit can only be set from ‘0’ to ‘1’ to
©2010 Silicon Storage Technology, Inc.
S71417-02-000
20
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
CE#
0 1 2 3 4 5 6 7
MODE 3
SCK
MODE 3
MODE 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
MODE 0
01
50 or 06
SI
STATUS
STATUS
REGISTER
REGISTER 1
7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
MSB
MSB
MSB
MSB
HIGH IMPEDANCE
SO
1417 EWSR1.0
FIGURE 21: Enable-Write-Status-Register (EWSR) or
Write-Enable (WREN) and Write-Status-Register (WRSR) Word-Data Input Sequence
The WRSR instruction can either execute a byte-data or a
word-data input. Extra data/clock input, or within byte-/
word-data input, will not be executed. The reason for the
byte support is for backward compatibility to products
where WRSR instruction sequence is followed by only a
byte-data.
JEDEC Read-ID
BFH, identifies the manufacturer as SST. Byte 2, 25H, identifies the memory type as SPI Serial Flash. Byte 3, 8CH,
identifies the device as SST25VF020B. The instruction
sequence is shown in Figure 22. The JEDEC Read ID
instruction is terminated by a low to high transition on CE#
at any time during data output.
The JEDEC Read-ID instruction identifies the device as
SST25VF020B and the manufacturer as SST. The device
information can be read from executing the 8-bit command,
9FH. Following the JEDEC Read-ID instruction, the 8-bit
manufacturer’s ID, BFH, is output from the device. After
that, a 16-bit device ID is shifted out on the SO pin. Byte 1,
CE#
MODE 3
SCK
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
MODE 0
9F
SI
SO
HIGH IMPEDANCE
BF
MSB
25
8C
MSB
1417 JEDECID.1
FIGURE 22: JEDEC Read-ID Sequence
TABLE 7: JEDEC Read-ID Data
Device ID
Manufacturer’s ID
Memory Type
Memory Capacity
Byte1
Byte 2
Byte 3
BFH
25H
8CH
T7.0 1417
©2010 Silicon Storage Technology, Inc.
S71417-02-000
21
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
Read-ID (RDID)
00001H. Once the device is in Read-ID mode, the manufacturer’s and device ID output data toggles between
address 00000H and 00001H until terminated by a low to
high transition on CE#.
The Read-ID instruction (RDID) identifies the devices as
SST25VF020B and manufacturer as SST. The device
information can be read from executing an 8-bit command,
90H or ABH, followed by address bits [A23-A0]. Following
the Read-ID instruction, the manufacturer’s ID is located in
address 00000H and the device ID is located in address
Refer to Tables 7 and 8 for device identification data.
CE#
MODE 3
SCK
0 1 2 3 4 5 6 7 8
23 24
15 16
31 32
39 40
47 48
55 56
63
MODE 0
90 or AB
SI
00
00
MSB
ADD1
MSB
HIGH IMPEDANCE
SO
BF
Device ID
BF
Device ID
HIGH
IMPEDANCE
MSB
Note: The manufacturer's and device ID output stream is continuous until terminated by a low to high transition on CE#.
Device ID = 8CH for SST25VF020B
1. 00H will output the manfacturer's ID first and 01H will output device ID first before toggling between the two.
1417 RdID.0
FIGURE 23: Read-ID Sequence
TABLE 8: Product Identification
Manufacturer’s ID
Address
Data
00000H
BFH
00001H
8CH
Device ID
SST25VF020B
T8.0 1417
©2010 Silicon Storage Technology, Inc.
S71417-02-000
22
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
ELECTRICAL SPECIFICATIONS
Absolute Maximum Stress Ratings (Applied conditions greater than those listed under “Absolute Maximum
Stress Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation
of the device at these conditions or conditions greater than those defined in the operational sections of this data
sheet is not implied. Exposure to absolute maximum stress rating conditions may affect device reliability.)
Temperature Under Bias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55°C to +125°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65°C to +150°C
D. C. Voltage on Any Pin to Ground Potential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to VDD+0.5V
Transient Voltage (<20 ns) on Any Pin to Ground Potential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -2.0V to VDD+2.0V
Package Power Dissipation Capability (TA = 25°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0W
Surface Mount Solder Reflow Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C for 10 seconds
Output Short Circuit Current1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA
1. Output shorted for no more than one second. No more than one output shorted at a time.
OPERATING RANGE
Range
AC CONDITIONS OF TEST
VDD
0°C to +70°C
2.7-3.6V
Output Load . . . . . . . . . . . . . . . . . . . . . CL = 30 pF
-40°C to +85°C
2.7-3.6V
See Figures 29 and 30
Commercial
Industrial
Input Rise/Fall Time . . . . . . . . . . . . . . . 5 ns
Ambient Temp
TABLE 9: DC Operating Characteristics
Limits
Symbol
Parameter
IDDR
Read Current
Min
Max
Units
12
mA
Test Conditions
IDDR3
Read Current
20
mA
CE#=0.1 VDD/0.9 VDD@80 MHz, SO=open
IDDW
Program and Erase Current
30
mA
CE#=VDD
ISB
Standby Current
20
µA
CE#=VDD, VIN=VDD or VSS
ILI
Input Leakage Current
1
µA
VIN=GND to VDD, VDD=VDD Max
ILO
Output Leakage Current
VIL
Input Low Voltage
VIH
Input High Voltage
VOL
Output Low Voltage
VOL2
Output Low Voltage
VOH
Output High Voltage
CE#=0.1 VDD/0.9 VDD@33 MHz, SO=open
1
µA
VOUT=GND to VDD, VDD=VDD Max
0.8
V
VDD=VDD Min
V
VDD=VDD Max
0.2
V
IOL=100 µA, VDD=VDD Min
0.4
V
IOL=1.6 mA, VDD=VDD Min
V
IOH=-100 µA, VDD=VDD Min
0.7 VDD
VDD-0.2
T9.0 1417
TABLE 10: Recommended System Power-up Timings
Symbol
TPU-READ
Parameter
1
TPU-WRITE1
Minimum
Units
VDD Min to Read Operation
10
µs
VDD Min to Write Operation
10
µs
T10.0 1417
1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter.
©2010 Silicon Storage Technology, Inc.
S71417-02-000
23
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
TABLE 11: Capacitance (TA = 25°C, f=1 Mhz, other pins open)
Parameter
Description
COUT1
Output Pin Capacitance
CIN
1
Input Capacitance
Test Condition
Maximum
VOUT = 0V
12 pF
VIN = 0V
6 pF
T11.0 1417
1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter.
TABLE 12: Reliability Characteristics
Symbol
Parameter
Minimum Specification
Units
Test Method
NEND1
Endurance
10,000
Cycles
JEDEC Standard A117
100
Years
JEDEC Standard A103
100 + IDD
mA
TDR
1
Data Retention
ILTH1
Latch Up
JEDEC Standard 78
T12.0 1417
1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter.
TABLE 13: AC Operating Characteristics
33 MHz
Symbol
Parameter
Min
80 MHz
Max
Min
Max
Units
80
MHz
FCLK1
Serial Clock Frequency
TSCKH
Serial Clock High Time
13
6
ns
TSCKL
Serial Clock Low Time
13
6
ns
TSCKR
2
33
Serial Clock Rise Time (Slew Rate)
0.1
0.1
V/ns
TSCKF
Serial Clock Fall Time (Slew Rate)
0.1
0.1
V/ns
TCES3
CE# Active Setup Time
5
5
ns
TCEH3
CE# Active Hold Time
5
5
ns
TCHS
3
CE# Not Active Setup Time
5
5
ns
TCHH3
CE# Not Active Hold Time
5
5
ns
TCPH
CE# High Time
50
TCHZ
CE# High to High-Z Output
TCLZ
SCK Low to Low-Z Output
0
0
ns
TDS
Data In Setup Time
2
2
ns
TDH
Data In Hold Time
4
4
ns
THLS
HOLD# Low Setup Time
5
5
ns
THHS
HOLD# High Setup Time
5
5
ns
THLH
HOLD# Low Hold Time
5
5
ns
THHH
HOLD# High Hold Time
5
THZ
HOLD# Low to High-Z Output
TLZ
HOLD# High to Low-Z Output
TOH
Output Hold from SCK Change
TV
Output Valid from SCK
10
6
ns
TSE
Sector-Erase
25
25
ms
TBE
Block-Erase
25
25
ms
TSCE
Chip-Erase
50
50
ms
TBP
Byte-Program
10
10
50
15
ns
7
5
7
7
0
ns
ns
7
ns
7
ns
0
ns
µs
T13.0 1417
1. Maximum clock frequency for Read Instruction, 03H, is 33 MHz
2. Maximum Rise and Fall time may be limited by TSCKH and TSCKL requirements
3. Relative to SCK.
©2010 Silicon Storage Technology, Inc.
S71417-02-000
24
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
TCPH
CE#
TCHH
TCES
TCEH
TSCKF
TCHS
SCK
TDS
SI
SO
TDH
TSCKR
MSB
LSB
HIGH-Z
HIGH-Z
1417 SerIn.0
FIGURE 24: Serial Input Timing Diagram
CE#
TSCKH
TSCKL
SCK
TOH
TCLZ
SO
TCHZ
MSB
LSB
TV
SI
1417 SerOut.0
FIGURE 25: Serial Output Timing Diagram
©2010 Silicon Storage Technology, Inc.
S71417-02-000
25
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
CE#
THHH
THHS
THLS
SCK
THLH
THZ
TLZ
SO
SI
HOLD#
1417 Hold.0
FIGURE 26: Hold Timing Diagram
©2010 Silicon Storage Technology, Inc.
S71417-02-000
26
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
Power-Up Specifications
All functionalities and DC specifications are specified for a VDD ramp rate of greater than 1V per 100 ms (0v - 3.0V
in less than 300 ms). See Table 14 and Figure 27 for more information.
TABLE 14: Recommended System Power-up Timings
Symbol
Parameter
TPU-READ1
Minimum
Units
VDD Min to Read Operation
100
µs
TPU-WRITE1
VDD Min to Write Operation
100
µs
T14.0 1417
1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter.
VDD
VDD Max
Chip selection is not allowed.
Commands may not be accepted or properly
interpreted by the device.
VDD Min
TPU-READ
TPU-WRITE
Device fully accessible
Time
1417 PwrUp.0
FIGURE 27: Power-up Timing Diagram
©2010 Silicon Storage Technology, Inc.
S71417-02-000
27
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
TABLE 15: Recommended Power-up/-down Limits
Limits
Symbol
Parameter
Min
Max
Units
TPF
VDD Falling Time
1
100
ms/V
TPR
VDD Rising Time
0.033
100
ms/V
TOFF
VDD Off Time
VOFF
VDD Off Level
100
Conditions
ms
0.3
V
0V (recommended)
T15.0
1417
VDD
VOFF
GND
TOFF
1417 F28.0
FIGURE 28: Recommended Power-up/-down Waveform
©2010 Silicon Storage Technology, Inc.
S71417-02-000
28
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
VIHT
VHT
INPUT?
VHT
REFERENCE POINTS
OUTPUT
VLT
VLT
VILT
1417 IORef.0
AC test inputs are driven at VIHT (0.9VDD) for a logic “1” and VILT (0.1VDD) for a logic “0”. Measurement reference points
for inputs and outputs are VHT (0.6VDD) and VLT (0.4VDD). Input rise and fall times (10% ↔ 90%) are <5 ns.
Note: VHT - VHIGH Test
VLT - VLOW Test
VIHT - VINPUT HIGH Test
VILT - VINPUT LOW Test
FIGURE 29: AC Input/Output Reference Waveforms
TO TESTER
TO DUT
CL
1417 TstLd.0
FIGURE 30: A Test Load Example
©2010 Silicon Storage Technology, Inc.
S71417-02-000
29
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
PRODUCT ORDERING INFORMATION
SST
25
XX
VF
XX
020
XXX
B - 80
X - XX
- 4C - SA
- XX - X X
E
X
Environmental Attribute
E1 = non-Pb
Package Modifier
A = 8 leads or contacts
Package Type
S = SOIC 150 mil body width
Q = WSON
Temperature Range
C = Commercial = 0°C to +70°C
I = Industrial = -40°C to +85°C
Minimum Endurance
4 = 10,000 cycles
Operating Frequency
80 = 80 MHz
Device Density
020 = 2 Mbit
Voltage
V = 2.7-3.6V
Product Series
25 = Serial Peripheral Interface flash memory
1. Environmental suffix “E” denotes non-Pb solder.
SST non-Pb solder devices are “RoHS Compliant”.
Valid combinations for SST25VF020B
SST25VF020B-80-4C-QAE
SST25VF020B-80-4I-QAE
SST25VF020B-80-4C-SAE
SST25VF020B-80-4I-SAE
Note: Valid combinations are those products in mass production or will be in mass production. Consult your SST sales
representative to confirm availability of valid combinations and to determine availability of new combinations.
©2010 Silicon Storage Technology, Inc.
S71417-02-000
30
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
PACKAGING DIAGRAMS
Pin #1
Identifier
TOP VIEW
SIDE VIEW
7°
4 places
0.51
0.33
5.0
4.8
1.27 BSC
END VIEW
4.00
3.80
6.20
5.80
45°
0.25
0.10
1.75
1.35
7°
4 places
0.25
0.19
Note: 1. Complies with JEDEC publication 95 MS-012 AA dimensions,
although some dimensions may be more stringent.
2. All linear dimensions are in millimeters (max/min).
3. Coplanarity: 0.1 mm
4. Maximum allowable mold flash is 0.15 mm at the package ends and 0.25 mm between leads.
0°
8°
08-soic-5x6-SA-8
1.27
0.40
1mm
FIGURE 31: 8-Lead Small Outline Integrated Circuit (SOIC) 150mil Body Width (5mm x 6mm)
SST Package Code: SA
©2010 Silicon Storage Technology, Inc.
S71417-02-000
31
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
TOP VIEW
SIDE VIEW
BOTTOM VIEW
Pin #1
0.2
Pin #1
Corner
1.27 BSC
5.00 ± 0.10
4.0
0.076
0.48
0.35
3.4
0.70
0.50
0.05 Max
6.00 ± 0.10
0.80
0.70
Note: 1. All linear dimensions are in millimeters (max/min).
2. Untoleranced dimensions (shown with box surround)
are nominal target dimensions.
3. The external paddle is electrically connected to the
die back-side and possibly to certain VSS leads.
This paddle can be soldered to the PC board;
it is suggested to connect this paddle to the VSS of the unit.
Connection of this paddle to any other voltage potential can
result in shorts and/or electrical malfunction of the device.
CROSS SECTION
0.80
0.70
1mm
8-wson-5x6-QA-9.0
FIGURE 32: 8-Contact Very-very-thin Small Outline No-lead (WSON)
SST Package Code: QA
©2010 Silicon Storage Technology, Inc.
S71417-02-000
32
04/10
2 Mbit SPI Serial Flash
SST25VF020B
Data Sheet
TABLE 16: Revision History
Number
00
01
02
Description
•
•
•
•
•
•
Initial release of data sheet
Updated Table 4 on page 6
Added Figure 28 and Table 15 on page 28
Changed TDS value in Table 13 on page 24
Updated SST address on page 33
Changed document status to “Data Sheet”
Date
Dec 2009
Feb 2010
Apr 2010
Silicon Storage Technology, Inc.
www.SuperFlash.com or www.sst.com
©2010 Silicon Storage Technology, Inc.
S71417-02-000
33
04/10