SYNQOR IQ24500HED08NRS-G

Technical
Specification
IQ24500HEx08
18-36 V
Input
50 V
Output
8 A
Current
2250 Vdc
Isolation
Half-brick
DC-DC Converter
The IQ24500HEx08 InQor™ Exa converter is an
isolated, fixed switching frequency DC-DC converter
that uses synchronous rectification to achieve extremely
high efficiency and power density. The 24 Vin modules
feature 2,250 Vdc isolation and low common mode
noise. The Exa series converters offer industry leading
usable output power for any standard “half-brick”
module. RoHS compliant (see last page).
Operational Features
•Ultra-high efficiency, 94% at full rated load current, 95%
at half rated load current
•Delivers up to 8 A of output current (400 W)
•Wide input voltage range: 18 – 36 V, with 50 V 100 ms
input voltage transient capability
•Fixed frequency switching provides predictable EMI performance
•No minimum load requirement means no preload resistors required
•Wide output voltage trim range (-50% to +10%)
Mechanical Features
• Industry standard half-brick pin-out configuration
• Brick size: 2.39" x 2.49" (63.1 x 60.6 mm)
• Total height only 0.512" (13 mm)
• Total weight: 4.3 oz. (123 grams)
Control Features
• On/Off control referenced to input side
IQ24500HEC08 Module
Protection Features
•Input under-voltage lockout disables converter at low input
voltage conditions
•Output current limit and short circuit protection protects
converter and load from damage and consequent hazardous conditions
•Active back bias limit provides smooth startup with
external load induced pre-bias
•Latching output over-voltage protection protects load from
damaging voltages
•Thermal shutdown protects converter from abnormal
environmental conditions
Safety Features
Contents
• 2250 V, 30 MΩ input-to-output isolation
• UL 60950-1:2003, basic insulation
• CAN/CSA-C22.2 No. 60950-1:2003
• EN60950-1:2001
• CE Marked
• RoHS compliant (see Page 12)
Product # IQ24500HEx08
Phone 1-888-567-9596
Page No.
Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
IQ24500HEx08 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . 3-4
Standards compliance and Qualification Testing . . . . . . . . . . . . . . . . . . . 4
IQ24500HEx08 Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7
Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-11
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
www.synqor.com
Doc.# 005-IHE2450 Rev. C
03/31/09
Page 1
18-36 V
50 V
8 A (400 W)
Half-brick
Input:
Output:
Current:
Package:
Technical Specification
Mechanical Diagram
2.486
2.00
1.400
1.000
±.020 [ 63.14
±0.5 ]
[ 50.8 ]
[ 35.56 ]
[
[ 25.4 ]
.700
[ 17.78 ]
.400
[ 10.16 ]
+.002
-.005
+0.05
13
-0.12
OVERALL
HEIGHT
.512
.243 ±.020
[ 6.17 ±0.5 ]
9
8
6
7
]
.163
[ 4.14 ]
5
.243 ±.020
[ 6.17 ±0.5 ]
2.386 ±.020
[ 60.6 ±0.5 ]
TOP VIEW
1.90
[ 48.3 ]
SIDE VIEW
1.90
[ 48.3 ]
.233 ±.020
[ 5.92 ±0.5 ]
1
2
4
3
.543
±.020 [ 13.79 ±0.5 ]
.400
[ 10.16 ]
1.00
[ 25.4 ]
1.400
THRU HOLE
M3 (SEE NOTE 8)
STANDOFFS (4)
+.007
-.010
+0.17
0.69
-0.25
BOTTOMSIDE CLEARANCE
.027
[
]
[ 35.56 ]
PIN DESIGNATIONS
NOTES
Pin
Name
Function
1
Vin(+)
Positive input voltage
2
ON/OFF
TTL input to turn converter on and off,
referenced to Vin(–), with internal pull up.
3
Reserved
Not Connected
4
Vout(–)
Negative output voltage
5
Vout(–)
6) UNDIMENSIONED COMPONENTS ARE SHOWN FOR VISUAL
REFERENCE ONLY
6
SENSE(–)
Negative output voltage
Negative remote sense1
7
TRIM
7) WEIGHT: 139g/4.9oz
8
SENSE(+)
Positive remote sense3
8) THREADED OR NON-THREADED OPTIONS AVAILABLE
9
Vout(+)
Positive output voltage
1) APPLIED TORQUE PER SCREW SHOULD NOT EXCEED 6in-lb (0.7Nm).
2) BASEPLATE FLATNESS TOLERANCE IS 0.004" (.10mm)
TIR FOR SURFACE.
3) PINS 1-4, 6-8 ARE 0.040" (1.02mm) DIA. WITH 0.080" (2.03mm)
DIA. STANDOFF SHOULDERS
4) PINS 5 AND 9 ARE 0.080" (2.03mm) DIA. WITH .125" (3.18) DIA.
STANDOFF SHOULDERS
5) ALL PINS: MATERIAL: COPPER ALLOY
FINISH: MATTE TIN OVER NICKEL PLATE
9) ALL DIMENSIONS IN INCHES(mm) TOLERANCES: X.XXIN +/-0.02
(X.Xmm +/-0.5mm X.XXXIN +/-0.010 (X.XXmm +/-0.25mm)
Product # IQ24500HEx08
Phone 1-888-567-9596
Output voltage trim2
Notes:
1)
SENSE(–) should be connected to Vout(–) either
remotely or at the converter.
2)
Leave TRIM pin open for nominal output voltage.
3)
SENSE(+) should be connected to Vout(+)
either remotely or at the converter.
www.synqor.com
Doc.# 005-IHE2450 Rev. C
03/31/09
Page 2
Input:
Output:
Current:
Package:
Technical Specification
18-36 V
50 V
8 A (400 W)
Half-brick
IQ24500HEx08 ELECTRICAL CHARACTERISTICS
TA=25°C, airflow rate=300 LFM, Vin=24Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C ambient
temperature with appropriate power derating. Specifications subject to change without notice.
Parameter ABSOLUTE MAXIMUM RATINGS
Input Voltage
Non-Operating
Operating
Operating Transient Protection
Isolation Voltage (input to output)
Operating Temperature
Storage Temperature
Voltage at ON/OFF input pin
INPUT CHARACTERISTICS
Operating Input Voltage Range
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Voltage Hysteresis
Maximum Input Current
No-Load Input Current
Disabled Input Current
Response to Input Transient
Input Reflected Ripple Current
Input Terminal Ripple Current
Recommended Input Fuse
Input Filter Component Values (L\C)
Recommended External Input Capacitance
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line1
Over Load1
Over Temperature
Total Output Voltage Range
Output Voltage Ripple and Noise2
Peak-to-Peak
RMS Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage3
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
DYNAMIC CHARACTERISTICS
Output Voltage during Load Current Transient
For a Step Change in Output C urrent (0.1 A/µs)
For a Step Change in Output Current (5 A/µs)
Settling Time
Turn-On Transient
Turn-On Time
Output Voltage Overshoot
EFFICIENCY
100% Load
50% Load
TEMPERATURE LIMITS FOR POWER DERATING CURVES
Semiconductor Junction Temperature
Board Temperature
Transformer Temperature
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength)
Isolation Resistance
Isolation Capacitance4
Note
Note
Note
Note
1:
2:
3:
4:
Min.
Typ.
Max.
Units Notes & Conditions
-40
-55
-2
50
40
50
2250
100
125
18
V
V
V
V
°C
°C
V
Continuous
Continuous
100 ms transient, square wave
Basic insulation, Pollution Degree 2
18
24
36
V
50 V transient for 100 ms
16.5
15.0
1.0
17.0
15.5
1.5
300
100
1.5
5
150
0.34\23
470
17.5
16.0
2.0
30
400
125
20
40
V
V
V
A
mA
mA
V
mA
mA
A
µH\µF
µF
48.60
50.00
51.35
V
48.5
0
9
1
0
+0.25\125
+0.25\125
+0.380
200
50
10
20
3
3
+1.000
51.45
250
65
8
11
4
7
1
%\mV
%\mV
V
V
mV
mV
A
A
V
A
mA
mF
2
2
8
V
V
ms
50% to 75% to 50% Iout max, 200 µF load cap
“
To within 1% Vout nom
24
35
40
2
ms
%
Full load, ON/OFF to Vout=90% nom.
No load, 1mF load cap
94
95
%
%
Figures 1 & 2
Figures 1 & 2
125
125
125
°C
°C
°C
Package rated to 150°C
UL rated max operating temp 130°C
2250
30
1000
V
MW
pF
100% Load, 18 Vin, trimmed up 10%
0.25 V/µs input transient
RMS thru 3.3 µH inductor
RMS
Fast blow external fuse recommended
Internal values; see Figure E
Typical ESR 0.1-0.2 W
Over sample, line, load, temperature & life
20 MHz bandwidth
Full Load
Full Load
Subject to thermal derating
Output Voltage 10% Low
Negative current drawn from output source
Negative current drawn from output source
8 A Resistive Load
Line and load regulation is limited by duty cycle quantization and does not indicate a shift in the internal voltage reference.
For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]).
If the output voltage falls below the Output DC Current Limit Shutdown Voltage for more than 50ms, then the unit will enter into hiccup mode, with a 500 ms off-time.
Higher values of isolation capacitance can be added external to the module.
Product # IQ24500HEx08
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IHE2450 Rev. C
03/31/09
Page 3
Input:
Output:
Current:
Package:
Technical Specification
18-36 V
50 V
8 A (400 W)
Half-brick
ELECTRICAL CHARACTERISTICS (Continued)
Parameter P
FEATURE CHARACTERISTICS
Switching Frequency Regulation Stage
Switching Frequency Isolation Stage
ON/OFF Control (Option N)
Off-State Voltage
On-State Voltage
ON/OFF Control
ON/OFF Control Hysteresis
Pull-Up Voltage
Pull Up Resistance
Output Voltage Trim Range
Output Over-Voltage Protection
Over-Temperature Shutdown
Over-Temperature Shutdown Restart Hysteresis
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia)
Calculated MTBF (MIL-217)
Field Demonstrated MTBF
Min.
Typ.
Max.
Units Notes & Conditions
232
116.0
235
117.5
237
118.5
kHz
kHz
4.0
-2
4.75
-50
113
1.5
5.00
10
118
120
10
18
1.0
5.25
+10
123
V
V
V
V
kW
%
%
°C
°C
TBD
TBD
Over sample, temp & life
Over sample, temp & life
Measured across Pins 9 & 5; see trim section
Over full temp range; % of nominal Vout
Average PCB Temperature
106 Hrs. TR-NWT-000332; 80% load,300LFM, 40ºC Ta
106 Hrs. MIL-HDBK-217F; 80% load, 300LFM, 40ºC Ta
106 Hrs. See website for details
Standards compliance and Qualification Testing
Parameter
Notes & Conditions
STANDARDS COMPLIANCE
UL 60950-1:2003
Basic Insulation
CAN/CSA-C22.2 No. 60950-1:2003
EN60950-1:2001
CE Marked
2006/95/EC Low Voltage Directive
IEC 61000-4-2
ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance)
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new
releases or download from the SynQor website.
Parameter
# Units
Test Conditions
QUALIFICATION TESTING
Life Test
32
95% rated Vin and load, units at derating point, 1000 hours
Vibration
5
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis
Mechanical Shock
5
100g minimum, 2 drops in x and y axis, 1 drop in z axis
Temperature Cycling
10
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Power/Thermal Cycling
5
Toperating = min to max, Vin = min to max, full load, 100 cycles
Design Marginality
5
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load
Humidity
5
85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day
Solderability
Product # IQ24500HEx08
15 pins
Phone 1-888-567-9596
MIL-STD-883, method 2003
www.synqor.com
Doc.# 005-IHE2450 Rev. C
03/31/09
Page 4
Input:
Output:
Current:
Package:
Technical Specification
100
18-36 V
50 V
8 A (400 W)
Half-brick
60
95
50
Power Dissipation (W)
Efficiency (%)
90
85
80
75
70
18 Vin
24 Vin
36 Vin
65
40
30
20
18 Vin
24 Vin
10
36 Vin
0
60
0
1
2
3
4
5
6
7
0
8
1
2
3
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25°C.
5
6
7
8
Figure 2: Power dissipation at nominal output voltage vs. load current
for minimum, nominal, and maximum input voltage at 25°C.
9
9
8
8
7
7
6
6
Iout (A)
Iout (A)
4
Load Current (A)
5
4
3
5
4
3
400 LFM (2.0 m/s)
2
400 LFM (2.0 m/s)
2
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
1
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
1
100 LFM (0.5 m/s)
100 LFM (0.5 m/s)
0
0
25
40
55
70
85
25
Ambient Air Temperature (°C)
40
55
70
85
Ambient Air Temperature (°C)
Figure 3: Encased converter (without heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 4: Encased converter (with 1/2” heatsink) max. output power derating vs.
ambient air temperature for airflow rates of 100 LFM through 400 LFM. Air flows
across the converter from input to output (nominal input voltage).
Figure 5: Turn-on transient at full load (resistive load) (10 ms/div).
Ch 1: Vout (10 V/div)
Ch 2: ON/OFF input (5 V/div)
Figure 6: Turn-on transient at zero load (10 ms/div).
Ch 1: ON/OFF input (5 V/div)
Ch 2: Vout (10 V/div)
Product # IQ24500HEx08
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IHE2450 Rev. C
03/31/09
Page 5
Input:
Output:
Current:
Package:
Technical Specification
Figure 7: Output voltage response to step-change in load current
(50%-75%-50% of Iout(max); dI/dt = 0.1 A/µs; 1 ms/div). Load cap:
1 uF ceramic and 330 µF, 15 mW ESR electrolitic capacitors. Top trace:
Vout (1 V/div). Bottom trace: Iout (5 A/div).
Figure 11
3.3 µH
source
impedance
Figure 8: Output voltage response to step-change in load current
(50%-75%-50% of Iout(max): dI/dt = 5 A/µs; 2 ms/div). Load cap:
330 µF, 15 mW ESR electrolytic capacitor. Top trace: Vout (1.0 V/div).
Bottom trace: Iout 10 A/div).
Figure 10
Figure 12
iS
VSOURCE
18-36 V
50 V
8 A (400 W)
Half-brick
iC
470 µF,
0.2W ESR
electrolytic
capacitor
DC-DC
Converter
VOUT
1 µF
ceramic
capacitor
100 µF,
10mW ESR
electrolytic
capacitor
Figure 9: Test set-up diagram showing measurement points for Input
Terminal Ripple Current (Figure 10), Input Reflected Ripple Current
(Figure 11) and Output Voltage Ripple (Figure 12).
Figure 10: Input Terminal Ripple Current, ic, at full rated output current and nominal input voltage with 3.3 µH source impedance and
470 µF electrolytic capacitor (200 mA/div; 2 µs/div). See Figure 9.
Figure 11: Input reflected ripple current, is, through a 3.3 µH source
inductor, using a 470 µF input capacitor, at nominal input voltage and
rated load current (10 mA/div; 2 µs/div). See Figure 9.
Figure 12: Output voltage ripple at nominal input voltage and rated load
current (50 mV/div; 2 µs/div). Load capacitance: 1 µF ceramic capacitor and 100 µF electrolytic capacitor. Bandwidth: 20 MHz. See Figure 9.
Product # IQ24500HEx08
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IHE2450 Rev. C
03/31/09
Page 6
Input:
Output:
Current:
Package:
Technical Specification
Figure 13: Output voltage response to step-change in input voltage (18
V to 36 V in 200 µs; 400 µs/div). Load cap: 470 µF, 15 mW ESR electrolytic capacitor. Top trace: Vin (5.0 V/div). Bottom trace: Vout (1.0 V/div),
at zero load current.
18-36 V
50 V
8 A (400 W)
Half-brick
Figure 14: Load current (5 A/div; 10 ms/div) as a function of time when
the converter attempts to turn on into a 1 mW short circuit.
61
57
Output Voltage (V)
53
49
45
41
37
33
18 Vin
29
24 Vin
25
36 Vin
21
-4
-2
0
2
4
6
8
10
12
Load Current (A)
Figure 15: Output voltage vs. load current showing typical current
limit curves and OVP shutdown point.
Product # IQ24500HEx08
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IHE2450 Rev. C
03/31/09
Page 7
Input:
Output:
Current:
Package:
Technical Specification
18-36 V
50 V
8 A (400 W)
Half-brick
BASICOPERATIONANDFEATURES
CONTROLFEATURES
Theconverterseriesusesatwo-stagepowerconversiontopology.
Thefirststagekeepstheoutputvoltageconstantovervariationsin
line,load,andtemperature.Thesecondstageusesatransformer
toprovidethefunctionsofinput/outputisolationandvoltagestepdowntoachievethelowoutputvoltagerequired.
REMOTE ON/OFF (Pin 2):TheON/OFFinput,Pin2,permits
the user to control when the converter is on or off. This input is
referencedtothereturnterminaloftheinputbus,Vin(-).
Both the first stage and the second stage switch at a fixed frequencyforpredictableEMIperformance.Rectificationofthetransformer’soutputisaccomplishedwithsynchronousrectifiers.These
devices,whichareMOSFETswithaverylowon-stateresistance,
dissipatesignificantlylessenergythanSchottkydiodes,enabling
theconvertertoachievehighefficiency.
The series of half-brick, quarter-brick and eighth-brick converters
usestheindustrystandardfootprintandpin-outconfiguration.
ON/OFF
ON/OFF
Vin(_)
Vin(_)
RemoteEnableCircuit
5V
ON/OFF
Vin(_)
Vin(_)
DirectLogicDrive
Figure A: Various circuits for driving the ON/OFF pin.
Product # IQ24500HEx08
Pin8shouldbeconnectedtoVout(+)andPin6shouldbeconnectedtoVout(-)atthepointontheboardwhereregulationisdesired.
If these connections are not made, the converter will deliver an
outputvoltagethatisslightlyhigherthanitsspecifiedvalue.
OUTPUT VOLTAGE TRIM (Pin 7):TheTRIMinputpermitsthe
user to adjust the output voltage across the sense leads up or
down according to the trim range specifications. SynQor uses
industrystandardtrimequations.
CMOS
OpenCollectorEnableCircuit
REMOTE SENSE(+) (Pins 8 and 6): The SENSE(+) inputs
correct for voltage drops along the conductors that connect the
converter’soutputpinstotheload.
Note:Theoutputover-voltageprotectioncircuitsensesthevoltage
acrossthesenseleads(pins8and6)todeterminewhenitshould
trigger,notthevoltageacrosstheconverter’soutputpins(pins9
and5).
NegativeLogic
(PermanentlyEnabled)
ON/OFF
The ON/OFF signal is active low (meaning that a low voltage
turnstheconverteron).FigureAdetailsfourpossiblecircuitsfor
drivingtheON/OFFpin.
Phone 1-888-567-9596
Todecreasetheoutputvoltage,theusershouldconnectaresistor
betweenPin7(TRIM)andPin6(SENSE(–)input).Foradesired
decreaseofthenominaloutputvoltage,thevalueoftheresistor
shouldbe:
Rtrim-down=
(
)
100% _ 2 kW
∆
where
www.synqor.com
∆% =
Vnominal–Vdesired x100%
Vnominal
Doc.# 005-IHE2450 Rev. C
03/31/09
Page 8
Input:
Output:
Current:
Package:
Technical Specification
Toincreasetheoutputvoltage,theusershouldconnectaresistor
betweenPin7(TRIM)andPin8(SENSE(+)input).Foradesired
increase of the nominal output voltage, the value of the resistor
shouldbe
Rtrim-up
Vnominal –2
(
) xV
1.225
=
DES+VNOM
kW
VDES–VNOM
FigureBgraphstherelationshipbetweenthetrimresistorvalue,
Rtrim-upandRtrim-down,showingthetotalrangetheoutputvoltagecanbetrimmedupordown.
100,000.0
100,000.0
Trim Resistance
Resistance (kOhms)
(kOhms)
Trim
10,000.0
10,000.0
18-36 V
50 V
8 A (400 W)
Half-brick
PROTECTIONFEATURES
Input Under-Voltage Lockout: The converter is designed
to turn off when the input voltage is too low, helping to avoid
an input system instability problem, which is described in more
detail in the application note titled “Input System Instability” on
the SynQor website. The lockout circuitry is a comparator with
DChysteresis.Whentheinputvoltageisrising,itmustexceedthe
typical“Turn-OnVoltageThreshold”value*beforetheconverter
willturnon.Oncetheconverterison,theinputvoltagemustfall
below the typical Turn-Off Voltage Threshold value before the
converterwillturnoff.
Output Current Limit:Iftheoutputcurrentexceedsthe“Output
DCCurrentLimitInception”point*,thenafastlinearcurrentlimit
controller will reduce the output voltage to maintain a constant
outputcurrent.Ifasaresult,theoutputvoltagefallsbelowthe
“Output DCCurrent Limit Shutdown Voltage”* for more than
50ms,thentheunitwillenterintohiccupmode,witha500ms
off-time.Theunitwillthenautomaticallyattempttorestart.
Back-Drive Current Limit: If there is negative output current
of a magnitude larger than the “Back-Drive Current Limit while
Enabled”specification*,thenafastback-drivelimitcontrollerwill
increasetheoutputvoltagetomaintainaconstantoutputcurrent.
If this results in the output voltage exceeding the “Output OverVoltageProtection”threshold*,thentheunitwillshutdown.The
fullI-VoutputcharacteristicscanbeseeninFigure15.
1,000.0
1,000.0
100.0
100.0
10.0
1.0
0.1
0.0
0
5
10
15
20
25
% Increase in Vout
30
30
35
35
40
40
45
45
50
50
Decrease in
in Vout
Vout
% Decrease
Figure
50 Vout
Vout module
module
FigureB:
B:Trim
TrimGraph
Graph for
for 28
Note: The TRIM feature does not affect the voltage at which the
output over-voltage protection circuit is triggered. Trimming the
output voltage too high may cause the over-voltage protection
circuittoengage,particularlyduringtransients.
ItisnotnecessaryfortheusertoaddcapacitanceattheTrimpin.
Thenodeisinternallyfilteredtoeliminatenoise.
Output Over-Voltage Limit: If the voltage directly across
the output pins exceeds the “Output Over-Voltage Protection”
threshold*, the converter will immediately stop switching. This
shutdown is latching; unlike other shutdown types, the converter
will not restart unless the input power is cycled or the ON/OFF
inputistoggled.
Over-Temperature Shutdown:Atemperaturesensoronthe
convertersensestheaveragetemperatureofthemodule.Thethermalshutdowncircuitisdesignedtoturntheconverteroffwhenthe
temperatureatthesensedlocationreachesthe“Over-Temperature
Shutdown” value*. It will allow the converter to turn on again
whenthetemperatureofthesensedlocationfallsbytheamountof
the“Over-TemperatureShutdownRestartHysteresis”value*.
Total DC Variation of Vout:Fortheconvertertomeetitsfull
specifications, the maximum variation of the DC value of Vout,
duetobothtrimmingandremoteloadvoltagedrops,shouldnot
begreaterthanthatspecifiedfortheoutputvoltagetrimrange.
*SeeElectricalCharacteristicspage.
Product # IQ24500HEx08
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IHE2450 Rev. C
03/31/09
Page 9
Input:
Output:
Current:
Package:
Technical Specification
APPLICATIONCONSIDERATIONS
Input System Instability:Thisconditioncanoccurbecause
any DC-DC converter appears incrementally as a negative
resistanceload.Adetailedapplicationnotetitled“InputSystem
Instability”isavailableontheSynQorwebsitewhichprovides
anunderstandingofwhythisinstabilityarises,andshowsthe
preferredsolutionforcorrectingit.
18-36 V
50 V
8 A (400 W)
Half-brick
Output Filtering and External Output Capacitance:
FigureDbelowshowstheinternaloutputfiltercomponents.This
filterdramaticallyreducesoutputvoltageripple.However,some
minimumexternaloutputcapacitanceisrequired,asspecifiedin
theOutputCharacteristicssectionontheElectricalSpecifications
page. No damage will occur without this capacitor connected,
butpeakoutputvoltageripplewillbemuchhigher.
Application Circuits:FigureCbelowprovidesatypicalcircuit
diagramwhichdetailstheinputfilteringandvoltagetrimming.
Input Filtering and External Input Capacitance:FigureD
belowshowstheinternalinputfiltercomponents.Thisfilterdramatically reduces input terminal ripple current, which otherwise
couldexceedtheratingofanexternalelectrolyticinputcapacitor.
The recommended external input capacitance is specified in the
InputCharacteristicssectionontheElectricalSpecificationspage.
More detailed information is available in the application note
titled“EMICharacteristics”ontheSynQorwebsite.
Vin(+)
Vin
External
Input
Filter
Vout(+)
Vsense(+)
Electrolytic
Capacitor
ON/OFF
Trim
Vsense(_)
Vin(_)
Rtrim-up
or
Rtrim-down
Cload
Iload
Vout(_)
Figure D: Typical application circuit (negative logic unit, permanently enabled).
L
Vin(+)
C
Vin(_)
Figure E: Internal Input Filter Diagram (component values listed on the specifications page).
Product # IQ24500HEx08
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IHE2450 Rev. C
03/31/09
Page 10
Input:
Output:
Current:
Package:
Technical Specification
Startup Inhibit Period: The Startup Inhibit Period ensures
that the converter will remain off for approximately 200
ms when it is shut down for any reason. When an output
short is present, this generates a 5 Hz “hiccup mode,” which
prevents the converter from overheating. In all, there are
seven ways that the converter can be shut down, initiating a
Startup Inhibit Period:
• Input Under-Voltage Lockout
• Output Over-Voltage Protection
• Over Temperature Shutdown
• Current Limit
• Short Circuit Protection
• Turned off by the ON/OFF input
Figure F shows three turn-on scenarios, where a Startup
Inhibit Period is initiated at t0, t1, and t2:
18-36 V
50 V
8 A (400 W)
Half-brick
When the ON/OFF pin goes high after t2, the Startup Inhibit
Period has elapsed, and the output turns on within the
typical Turn-On Time.
Thermal Considerations: The maximum operating baseplate temperature, TB, is 100 ºC. As long as the user’s
thermal system keeps TB < 100 ºC, the converter can
deliver its full rated power.
A power derating curve can be calculated for any heatsink
that is attached to the base-plate of the converter. It is only
necessary to determine the thermal resistance, RTHBA, of the
chosen heatsink between the base-plate and the ambient air
for a given airflow rate. This information is usually available
from the heatsink vendor. The following formula can the be
used to determine the maximum power the converter can
dissipate for a given thermal condition if its base-plate is to
be no higher than 100 ºC.
Before time t0, when the input voltage is below the UVL
threshold, the unit is disabled by the Input Under-Voltage
Lockout feature. When the input voltage rises above the
UVL threshold, the Input Under-Voltage Lockout is released,
and a Startup Inhibit Period is initiated. At the end of this
delay, the ON/OFF pin is evaluated, and since it is active,
the unit turns on.
This value of power dissipation can then be used in
conjunction with the data shown in Figure 2 to determine
the maximum load current (and power) that the converter
can deliver in the given thermal condition.
At time t1, the unit is disabled by the ON/OFF pin, and it
cannot be enabled again until the Startup Inhibit Period
has elapsed.
For convenience, Figures 3 and 4 provide Power derating
curves for an encased converter without a heatsink and
with a typical heatsink.
max
Pdiss =
100 ºC - TA
RTHBA
Vin
Under-Voltage
Lockout TurnOn Threshold
ON/OFF
(neg logic)
ON
OFF ON
Vout
OFF
ON
9ms (typical
turn on time)
200ms
(typical start-up
inhibit period)
t0
200ms
200ms
t1
t
t2
Figure F: Startup Inhibit Period (turn-on time not to scale)
Product # IQ24500HEx08
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-IHE2450 Rev. C
03/31/09
Page 11
Input:
Output:
Current:
Package:
Technical Specification
18-36 V
50 V
8 A (400 W)
Half-brick
PART NUMBERING SYSTEM
ORDERING INFORMATION
The part numbering system for SynQor’s dc-dc converters
follows the format shown in the example below.
The tables below show the valid model numbers and ordering
options for converters in this product family. When ordering
SynQor converters, please ensure that you use the complete
15 character part number consisting of the 12 character
base part number and the additional characters for options.
Add “-G” to the model number for 6/6 RoHS compliance.
I Q 2 4 5 00 H E C 0 8 N R S -G
6/6 RoHS
Options
(see
Ordering Information)
Model Number
Input
Voltage
Output
Voltage
Max Output
Current
IQ24280HEw14NRS-G
18 - 36 V
28 V
14 A
IQ24500HEw08NRS-G
18 - 36 V
50 V
8A
Output Current
Thermal Design
Performance Level
Package Size
The following options must be included in place of the w x y z
spaces in the model numbers listed above.
Output Voltage
Input Voltage
Options Description: w x y z
Product Family
Thermal Design
The first 12 characters comprise the base part number and
the last 3 characters indicate available options. The “-G”
suffix indicates 6/6 RoHS compliance.
Application Notes
A variety of application notes and technical white papers can
be downloaded in pdf format from our website.
RoHS Compliance: The EU led RoHS (Restriction of Hazardous
Substances) Directive bans the use of Lead, Cadmium, Hexavalent
Chromium, Mercury, Polybrominated Biphenyls (PBB), and
Polybrominated Diphenyl Ether (PBDE) in Electrical and Electronic
Equipment. This SynQor product is 6/6 RoHS compliant. For
more information please refer to SynQor’s RoHS addendum
available at our RoHS Compliance / Lead Free Initiative web
page or e-mail us at [email protected].
C - Encased with
Threaded Baseplate
D - Encased with
Non-Threaded Baseplate
Enable Logic
Pin Style
Feature Set
N - Negative
R - 0.180"
S - Standard
Not all combinations make valid part numbers, please contact
SynQor for availability. See the Product Summary web page for
more options.
PATENTS
SynQor holds the following patents, one or more of which
might apply to this product:
5,999,417
6,594,159
6,927,987
7,119,524
6,222,742
6,731,520
7,050,309
7,269,034
6,545,890
6,894,468
7,072,190
7,272,021
6,577,109
6,896,526
7,085,146
7,272,023
Contact SynQor for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
Product # IQ24500HEx08
978-849-0600
888-567-9596
978-849-0602
[email protected]
www.synqor.com
155 Swanson Road
Boxborough, MA 01719
USA
Phone 1-888-567-9596
Warranty
SynQor offers a two (2) year limited warranty. Complete warranty
information is listed on our website or is available upon request from
SynQor.
Information furnished by SynQor is believed to be accurate and reliable.
However, no responsibility is assumed by SynQor for its use, nor for any
infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any
patent or patent rights of SynQor.
www.synqor.com
Doc.# 005-IHE2450 Rev. C
03/31/09
Page 12