FEATURES/特長
•
•
•
•
•
•
•
High reliability for vehicle application.
Operating temperature range : –55°C~+125°C
12.8mm Max. square, 6.8mm Max. height.
Magnetically shielded construction and low DC resistance.
Suitable for large currents.
Ideal for a variety of DC-DC converter inductor applications.
RoHS compliant.
•
•
•
•
•
•
•
車載機器向け信頼性向上品
使用温度範囲:–55°C∼+125°C
12.8mm角Max. 高さ6.8mm Max.
閉磁路構造、低直流抵抗
大電流対応
各種機器のDC-DCコンバータ用インダクタに最適
RoHS指令対応
SELECTION GUIDE FOR STANDARD COILS
TYPE DSH126C (With Ferrite Shield) 閉磁路タイプ(リングコア有り) (Quantity/reel; 500 PCS)
(1)
東光品番
インダクタンス
TOKO
Part
Number
Inductance
L (μH)
(1)
許容差
(2)
直流抵抗
Tolerance
(%)
DC
(2)
Resistance
(mΩ) Max.
± 30
± 30
± 30
± 30
± 30
± 20
± 20
± 20
± 20
± 20
± 20
± 20
± 20
± 20
± 20
± 20
10
12
15
16
22
24
32
43
65
105
135
170
280
410
555
780
(3)
直流重畳許容電流
Inductance
(3)
Decrease Current
(A) Max.
ΔL =30%
L
A1009AYW-1R8N
A1009AYW-2R7N
A1009AYW-3R9N
A1009AYW-5R6N
A1009AYW-7R5N
A1009AYW-100M
A1009AYW-150M
A1009AYW-220M
A1009AYW-330M
A1009AYW-470M
A1009AYW-680M
A1009AYW-101M
A1009AYW-151M
A1009AYW-221M
A1009AYW-331M
A1009AYW-471M
1.8
2.7
3.9
5.6
7.5
10.0
15.0
22.0
33.0
47.0
68.0
100.0
150.0
220.0
330.0
470.0
(1) Inductance is measured with a LCR meter 4284A (Agilent
Technologies) or equivalent.
Test frequency at 100kHz
(2) DC Resistance is measured with a Digital Multimeter TR6871
(Advantest) or equivalent.
(3) Maximum allowable DC current is that which inductance decrease
current, or temperature rise current, whichever is smaller.
・ Inductance decrease current : The inductance value decreases
30% by the excitation of DC current. (reference ambient
temperature 125°C)
・ Temperature rise current : The temperature rises 20°C by
excitation of DC current. (reference ambient temperature 20°C)
10.00
8.50
7.10
6.00
5.20
4.80
3.80
3.30
2.50
2.00
1.80
1.50
1.20
0.99
0.80
0.65
(3)
温度上昇許容電流
Temperature
(3)
Rise Current
ΔT=20°C
(A) Max.
6.30
5.30
4.90
4.50
3.80
3.50
3.00
2.40
2.00
1.50
1.30
1.10
0.85
0.72
0.57
0.49
(1) インダクタンスはLCRメータ4284A(Agilent Technologies)または
同等品により測定する。
測定周波数は100kHzです。
(2) 直流抵抗はデジタルマルチメータTR6871(Advantest)または同等
品により測定する。
(3) 最大許容電流:直流重畳許容電流値と温度上昇許容電流値の何れ
か小さい値です。
・ 直流重畳許容電流:直流重畳特性においてインダクタンス値が
30%低下した時の電流値。(周囲温度125°C)
・ 温度上昇許容電流:直流を流した時の巻線温度上昇が20°Cに達
する電流値。(周囲温度20°C)