VOLGEN MSS15-4805

Features
●Ultra compact size : 25.4x25.4x10.2mm
●Remote On/Off
●Primary-Secondary Isolation Voltage DC2200V(AC 1500V)
Type
15W
Input
MODEL
Voltage(.V)
MSS15-2403
MSS15-2405
24V(18V~36V)
MSS15-2412
MSS15-2415
MSS15-4803
MSS15-4805
48V(36V~75V)
MSS15-4812
MSS15-4815
Output
Voltage(V)
3.3
5
12
15
3.3
5
12
15
Output
Current(A)
0~3.5
0~3.0
0~1.25
0~1.0
0~3.5
0~3.0
0~1.25
0~1.0
Dimension
(W x H x D mm)
mm)
25.4 x 10 x 25.4
(1.0 x 0.4 x 1 inches)
MSseries
Specification Specification MSS15
MSS15 15 24V
24V Input Model
Model
Input
Range
Output
Voltage
Input
Output
Specificatio Current
n
Efficiency
Start-Up time
Output voltage
set accuracy
Ripple & Noise
*1
Input
Regulation
Load
Output Regulation(10Specificatio 100%Load)
n
Temperature
Coefficiency
Drift
MSS15-2403
V
A
%
3
0~3.5
84
MSS15-2405
MSS15-2412
24V(18~36V)
5
12
0~3.0
0~1.25
86
86
20mS typ
MSS15-2415
15
0~1.0
85
±5%
mV
200
200
150
150
mV
20
20
20
20
mV
25
25
25
25
0.02%/℃ max
(0.5%+15mV)max / 8H(1hour later)
Works Over 105% of rating and recovers automatically. Over current
protection protects the unit from short-circuit and over-current
condition of less than 20sec. Leaving short circuit or using under
Over Current
over-current cause the unit to malfunction.
Protection
25.4 x 10.0 x 25.4 (W x H x D)
Dimension
mm
Others
12
Weight
g
*1 Please refer to "Measuring method of Ripple and Noise" in Operation manual as for measuring method.
mV
mV
Specification Specification MSS15
MSS15 15 48V
48V Input Model
Model
Input
Range
Output
Voltage
Input
Output
Specificatio Current
n
Efficiency
Start-Up time
Ripple & Noise
*1
Input
Regulation
Load
Regulation(10Output 100%負荷)
Specificatio Temperature
n
Coefficiency
Drift
MSS15-4803
MSS15-4805
MSS15-4812
48V(36~75V)
5
12
0~3.0
0~1.25
87
87
30mS typ
MSS15-4815
V
A
%
3
0~3.5
85
15
0~1.0
86
mV
200
200
150
150
mV
20
20
20
20
mV
25
25
25
25
0.02%/℃ max
(0.5%+15mV)max / 8H(1hour later)
Works Over 105% of rating and recovers automatically. Over current
protection protects the unit from short-circuit and over-current
condition of less than 20sec. Leaving short circuit or using under
Over Current
over-current cause the unit to malfunction.
Protection
25.4 x 10.0 x 25.4 (W x H x D)
Dimension
mm
Others
12
Weight
g
*1 Please refer to "Measuring method of Ripple and Noise" in Operation manual as for measuring method.
Input Voltage Range
Temperature
Humidity
Isolation Voltage
(Room temperature and
Humidity)
Withstand Voltage
Vibration
Impact
Cooling Method
EMI
mV
mV
24V
24V Model(
Model(18~
18~36V
36V), 48V
48V Model(
Model(36V
36V~
75V
75V)
Operating Temperature
Storage Temperature
Operating Temperature
Storage Temperature
Primary-Secondary DC500V
Primary-Case DC500V
Secondary-Case DC500V
Primary-Secondary faradic current 10mA
Primary-Case faradic current 10mA
Secondary-Case faradic current 10mA
10 - 55Hz 0.5mm 3axis 30minute each
20G(3axis each)
Naturally
FCC Part15 EN55022 VCCI(B)
※Please Refer to the Operation Manual.
-20 - 60℃※
-20 - 85℃
20 non
- 85%
condensation
More than 100M
Ω
More than 100M
Ω
More than 100M
Ω
2200V
500V
500V
◇MSS15
1. Pines Discription
Please refer to their own specifications.
2. Over Current Protection
If output current exceeds more 105% than rated output of the power supply, The
overcurrent protection will activate and output voltage will drop. The power supply
will function normally once the overcurrent condition has been removed.
*Over current protection protects the unit from short-circuit and over-current
condition of less than 20sec. Using under over-current cause the unit to
malfunction.
3. Operation Temperature and Output Capability
The range of temperature over which a power supply can be operated safely is
critical to the overall life of the power supply. Operate the power supply in safe
ambient condition by considering the necessary convection or forced air cooling
requirement.
MSS15-2403, MSS15-2405, MSS15-4803, MSS4805
Load factor
Ambient Temperature
MSS15-2412, MSS15-2415, MSS15-4812, MSS4815
Load factor
Ambient Temperature
4. Pattern Layout
If patterns are put under the power supply unit, it can be caused of increasing
conduction noise and cut-down of efficiency. Please put patten away from the power
supply unit. If DC output pattern put under the power supply unit, It may makes
output noise larger. Please put patten away from the power supply unit.
5. Measuring method of Ripple and Noise
Measurement condition
Vr: Testing point of output voltage, output regulation.
Vn: Testing point of ripple/noise (using bayonet probe).
C1: 33uF electrolytic capacitor
C2: 1uF film capacitor
C3: 10uF electroytic capacitor
* In using, Please connect about 33uF electrolytic capacitor to the input terminal.
Remote On/Off
ON : RC Pin Open
OFF: RC Pin - -Vin Pin Short
( 25℃)
6.Soldering
Dip 240℃~255℃ ((within five seconds)
Hand solder 350±10℃ (within three seconds)
7.Handling Instruction
Using too large of capacitor (10,000μF) on your load may prevent the power supply from providing the
rated output voltage. Please consider load capacitance in your application.
8.Warrantly
KAGA Components offers a 3 year warranty and we will repair or replace the power supply at no charge
to the customer, provided the power supply has not been determined damaged or defective as a direct
result of misuse or mishandling by the user.
9.Others
These power supplies are our standard products and designed for general purpose applications. They
are not designed for use in life support systems, equipment used in hazardous environments, or nuclear
control systems.