XPPOWER IS0503SA

xppower.com
Specification
•
Regulated Single Output
•
SIP Package
•
1000 VDC Isolation
•
Optional 3000 VDC Isolation
•
Continuous Short Circuit Protection
•
Non-conductive Black Plastic Case
•
MTBF >1.1 MHrs
Input
Voltage
Input
No Load
Input Current
Setpoint Accuracy
•
Ripple & Noise
•
Temperature Coefficient •
Short Circuit Protection •
Maximum Capacitive
•
Load
See table
No minimum load required
±0.5% max
±0.5% max (0% to full load)
±1.5% for 3.3 V versions
±2% max
75 mV pk-pk (20 MHz bandwidth)
±0.02%/°C
Continuous with auto recovery
470 µF
5V
600
600
333
250
200
125
mA
mA
mA
mA
mA
mA
53%
62%
67%
70%
68%
64%
IS0503SA
IS0505SA
IS0509SA
IS0512SA
IS0515SA
IS0524SA
12 V
60
60
60
60
60
60
mA
mA
mA
mA
mA
mA
3.3
5.0
9.0
12.0
15.0
24.0
V
V
V
V
V
V
600
600
333
250
200
125
mA
mA
mA
mA
mA
mA
55%
60%
67%
69%
70%
68%
IS1203SA
IS1205SA
IS1209SA
IS1212SA
IS1215SA
IS1224SA
24 V
30
30
30
30
30
30
mA
mA
mA
mA
mA
mA
3.3
5.0
9.0
12.0
15.0
24.0
V
V
V
V
V
V
600
600
333
250
200
125
mA
mA
mA
mA
mA
mA
54%
61%
65%
70%
71%
71%
IS2403SA
IS2405SA
IS2409SA
IS2412SA
IS2415SA
IS2424SA
Mechanical Details
See table
1000 VDC (3000 VDC -H option)
60 pF
50 kHz typical
>1.1 MHrs to MIL-STD 217F
1 2 3
0.02
(0.50)
-25
°C to +70 °C
1.26
(32.00)
-40
°C to +125 °C
Printed Face
+100 °C max
Convection-cooled
Derate from 100% load at +70 °C
to 0% load at +85 °C 0.12
(3.05)
• Up to
90%, non-condensing
0.10
(2.54)
0.13
(3.40)
1.10
(27.94)
Notes
1. Add suffix ‘-H’ to model number for 3000 VDC isolation.
2. All dimensions in inches (mm).
0.32
(8.00)
0.13
(3.40)
0.10
(2.50)
0.12
(3.05)
0.10
(2.54)
1.10
(27.94)
•
•
•
•
•
0.13
(3.40)
0.55
(14.00)
Environmental
Humidity
0.32
(8.00)
Printed Face
0.02
(0.50)
Operating Temperature
Storage Temperature
Case Temperature
0.55
Cooling
(14.00)
Derating
Model
Number(1)
V
V
V
V
V
V
1.26
(32.00)
•
•
•
•
•
Efficiency
3.3
5.0
9.0
12.0
15.0
24.0
General
Efficiency
Isolation Voltage
Isolation Capacitance
Switching Frequency
MTBF
Output
Current
mA
mA
mA
mA
mA
mA
Output
•
•
•
•
Output
Voltage
100
100
100
100
100
120
Input Voltage Range
• Nominal ±10%
Input Current (no load) • See table
Input Reflected Ripple • 20 mA pk-pk through 12 µH inductor,
5 Hz to 20 MHz
Output Voltage
Minimum Load
Line Regulation
Load Regulation
DC-DC
3 Watts
IS Series
0.03
(0.68)
0.13
(3.40)
1 2 3
0.10
(2.50)
9 10 11 12
0.02
(0.50)
0.01
(0.25)
Pin
1
2
3
9
10
11
12
Standard ‘H’ Versions
+Vin
+Vin
N.C.
-Vin
N.C.
N.C.
N.C.
N.C.
-Vout
-Vout
+Vout
+Vout
-Vin
N.C.
03-Dec-07